112
Views
0
CrossRef citations to date
0
Altmetric
Original Articles

NMAM Methods Update: A Laboratory Response to Concerns About Technologically Outdated and Problematic Methods

, &
Pages 390-396 | Published online: 23 Oct 2007
 

The National Institute for Occupational Safety Health (NIOSH) publishes the NIOSH Manual of Analytical Methods (NMAM). The NMAM, although subject to various revisions and the incorporation of supplemental editions over the years, still contains many methods that are technologically outdated or problematic, as identified in a recent survey of the various users of the NMAM. Whereas the survey identified a number of problematic methods based on various chromatographic techniques, those selected for inclusion in this project employed analysis by gas chromatography (GC). The GC methods selected for evaluation were categorized as Phases 1, 2, 3, and 4 based on necessity as determined by the results of the client survey or internal assessment. The Phase 1 methods included: NMAM 1606 (Acetonitrile), NMAM 2005 (Nitroaromatic Compounds), and NMAM 1453 (Vinyl Acetate); the Phase 2 methods: NMAM 1003 (Halogenated Hydrocarbons), NMAM 1501 (Aromatic Hydrocarbons), NMAM 2555 (Ketones I), and NMAM 1403 (Alcohols IV); the Phase 3 methods: NMAM 2552 (Methyl Acrylate), NMAM 2537 (Methyl and Ethyl Methacrylate), and NMAM 2553 (Ketones II), and the Phase 4 methods: NMAM 2556 (Isophorone), NMAM 1460 (Isopropyl Acetate), and NMAM 1618 (Isopropyl Ether).

All methods previously specifying packed column chromatography have been evaluated using the appropriate fused silica capillary column. Improvements in individual analyte desorption efficiencies were achieved at concentrations substantially lower than those used in the previous methods. Most analytes evaluated had their respective limit of detection lowered by a factor of ten-to twentyfold. Thirty-day storage stability studies, previously lacking in a number of methods or for new analytes, were successfully completed to meet current method development criteria. Additional benefits resulting from this effort included the incorporation of single analyte methods into chemically related multianalyte methods and the evaluation of certain isomers, such as the methylstyrenes and xylenes, which previously could not be separated.

Notes

A Stabilwax and Rtx columns are products of Restek.

B All Anasorb sorbents were obtained from SKC, Inc.

C Sorbent obtained from Supelco (Bellefonte, Pa.).

D OSHA method used Ambersorb XE-347 tubes which are no longer being manufactured.

E The packed column method for vinyl acetate was adapted from OSHA Method No. 51 from which the desorption efficiency was based.Citation (4)

A All Stabilwax and Rtx columns are products of Restek.

B All sorbents were obtained from SKC, Inc.

C Methyl ethyl ketone (MEK) was previously a single analyte method (NMAM 2500).

D Method calls for a beaded carbon tube: Anasorb 747 (SKC 226-81), Anasorb CMS (SKC 226-121), Carboxen-564 (Supelco ORBO 90), or equivalent.

E Desorption efficiency and stability studies were conducted using Ambersorb XE-347 tubes (equivalent to a current Anasorb 747 tube).

F Recovery was 90% after 6 weeks at 25°C.

A All Rtx columns are products of Restek.

B All sorbents were obtained from SKC, Inc.

C Column is a product of J&W Scientific, Inc. (Folsom, Calif.).

D No official previous method for ethyl methacrylate exists. Previously, NMAM 2537 was a single analyte method for methyl methacrylate.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.