150
Views
3
CrossRef citations to date
0
Altmetric
Original Articles

SIMULTANEOUS DETERMINATION OF GUAIFENESIN AND EPHEDRINE HCl BINARY MIXTURE IN SYRUP DOSAGE FORMS AND HUMAN PLASMA BY USING RP-HPLC-DAD

&
Pages 1039-1051 | Published online: 28 Jan 2014
 

Abstract

A new and simple quantitative analysis method for the determination of Guaifenesin (G) and Ephedrine HCl (E) binary mixtures was developed and validated. Phosphate buffer–methanol combination (60:40, v/v) was chosen as an isocratic mobile phase and adjusted to pH 3 for this liquid chromatographic method which was developed for the simultaneous analysis of G and E combination. The method was observed in concentration ranges of 30–100 µg mL−1 (G) and 15–50 µg mL−1(E). The total run time for detections performed at 212 nm was less than 10 min.

The reverse phase-high performance liquid chromotography (RP-HPLC) method developed in this study was successfully applied to pharmaceutical preparations in syrup dosage form and human plasma samples (in vitro) without liquid–liquid extraction. And the statistical comparison of this method was performed both in pharmaceutical preparations and human plasma samples.

Notes

RSD: relative standard deviation (100 SD/mean), LOQ (S/N = 8), LOD (S/N = 3).

X: mean value, SD: standard deviation, RSD: relative standard deviation (100 SD/mean).

X: mean value, SD: standard deviation, RSD: relative standard deviation (100 SD/mean).

Recovery: (found/added)100, Accuracy (relative error): (found − added/added)100.

Recovery: (found/added)100, Accuracy (relative error): (found − added/added)100.

X: mean recovery, SD: standard deviation, RSD: relative standard deviation (100 SD/mean).

Recovery: (found/added)100, Accuracy (relative error): (found − added/added)100.

X: mean recovery, SD: standard deviation, RSD: relative standard deviation (100 SD/mean).

Recovery: (found/added)100, SD: standard deviation, RSD: relative standard deviation (100 SD/mean).

Standard error: standard deviation/√n, tC: calculated t-value, tT: tabulated t-value.

Standard error: standard deviation/√n, FC: calculated F-value, FT: tabulated F-value.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 583.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.