A validated high performance liquid chromatography – diode array detector method for the quantification of mitomycin C in plasma, peritoneal fluid and urine

, , , , , ORCID Icon, & show all
Pages 839-848 | Received 03 Jul 2018, Accepted 08 Sep 2018, Published online: 30 Nov 2018
 

Abstract

Mitomycin C (MMC) is a quinone-containing alkylating agent, that has been extensively studied in preclinical and clinical work due to its antitumor activity. A thoroughly validated high performance liquid chromatography-diode array detector method is provided to quantify MMC in plasma, peritoneal fluid and urine. Porfiromycin served as internal standard. The mobile phase for the plasma, peritoneal fluid and urine analysis consisted of 27% MeOH and 73% 20 mM ammoniumacetate buffer (pH 6.5) and 9% ACN and 91% 20 mM phosphate buffer (pH 6.5) respectively. The residue from 100 µL ACN deproteinated plasma was dissolved in 250 µL mobile phase. Peritoneal fluid and urine were diluted 10-fold in their respective mobile phases. UV detection was performed at 365 nm. Quantification of MMC was achieved over a linear range of 0.05–5 µg/mL and 5–50 µg/mL in plasma; 0.1–5 µg/mL and 5–100 µg/mL in peritoneal fluid; 0.25–5 µg/mL and 5–100 µg/mL in urine. The limit of quantification was 0.05 µg/mL in plasma, 0.1 µg/mL in peritoneal fluid and 0.25 µg/mL in urine. The method was further validated for selectivity, specificity, inter- and intraday precision and accuracy (≤15%), extraction recovery and stability. MMC remains stable in the different biofluids for 20 days (short-term stability) at 4 °C, −27 °C and −80 °C and for 80 days (long-term stability) at −80 °C.

Graphical Abstract

Acknowledgments

Erik Royackers for his contribution in the initial stages of conducting this research. Suzanne Driessens for the technical support during the HPLC-DAD analysis. Karel Haesevoets for making the graphical abstract.

Disclosure statement

No potential conflict of interest was reported by the authors.

Additional information

Funding

This work was supported by the Agency for Innovation by Science and Technology (IWT) in Brussels, Belgium [grant number 141631]. Lieselotte Lemoine and Kurt Van der Speeten are researchers for the Limburg Clinical Research Program (LCRP) supported by the foundation Limburg Sterk Merk (LSM), Hasselt University, Ziekenhuis Oost-Limburg and Jessa Hospital, Belgium.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 583.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.