66
Views
0
CrossRef citations to date
0
Altmetric
Research Articles

An HP-TLC densitometric method and fingerprinting for estimating capecitabine and thymoquinone simultaneously and its application in nanoscience using Box–Behnken design

ORCID Icon, &
Pages 217-225 | Published online: 01 Mar 2023
 

Abstract

World Health Organization estimates that 10% of medications are of inferior quality, thus dangerous to human health. One way to avoid such a problem is to create an adequate, economical, and competitive analytical system. As a result, the study’s goal is to create a High-Performance Thin Layer Chromatography (HP-TLC) method for determining capecitabine (CAP) and thymoquinone (TQ) simultaneously. To the best of our knowledge, no such method for determining CAP and TQ simultaneously exists today. The method was created by implementing an analytical quality-by-design approach based on the Box–Behnken design (BBD) to optimize the chromatographic conditions and a combination of factors such as toluene volume (A), solvent front (B), and chamber saturation time (C), all of which were likely to affect the Rf of CAP and TQ, respectively, later validated using TLC-silica coated plate 60 F254. The validated parameters were within an acceptable range, according to ICH guidelines. BBD design revealed that the volume of toluene and solvent front had a greater effect on all of the responses studied and thus needs to be controlled. The developed method of the analysis was found to be facile, dependable, expeditious, cost-effective, and could be used to quantify CAP and TQ in Nanoformulation.

Graphical Abstract

    RESEARCH HIGHLIGHTS

  • To determine both the drugs in nanoformulation, an accelerated and expeditious densiometric HP-TLC method was developed and validated.

  • Particle size, zeta potential, entrapment efficiency (EE), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM) analysis were all performed on the prepared nanoformulation.

  • According to ICH guidelines, the developed method has been tested for linearity, range, detection limit, quantification limit, precision, and robustness.

  • A review of the literature reveals that there are several methods for determining CAP and TQ individually but no HP-TLC method has been reported for simultaneous estimation of CAP and TQ in the combined dosage form.

  • Changes in mobile phase volume and changes in chamber saturation duration showed percent RSD-within the 2% criterion, confirming the robustness of the developed method.

Acknowledgments

The authors would also like to thank the director of the Analytical Laboratory at KAHER's BSRC in Belagavi, Karnataka, India, for providing the facilities needed to complete this study.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 583.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.