292
Views
1
CrossRef citations to date
0
Altmetric
Original Articles

Prediction of time of delivery using cervical length measurement in women with threatened preterm labor

, , , , ORCID Icon &
Pages 2649-2654 | Received 12 Mar 2019, Accepted 18 Sep 2019, Published online: 01 Oct 2019
 

Abstract

Objective

To evaluate the use of transvaginal (TV) sonographic cervical length (CL) measurement alone in predicting time of delivery in women who present in threatened preterm labor.

Methods

A retrospective cohort study at Royal Brisbane and Women’s Hospital of all women who presented between 22 weeks and 0 days and 35 weeks and six-day gestation in threatened preterm labor and were admitted for ongoing management including a TV sonographic CL measure. The accuracy of CL for predicting time of delivery was compared between women with a short cervix (CL  < 25 mm) and those with a normal cervix (CL ≥25 mm). The predictive accuracy of CL for spontaneous preterm delivery was analyzed with different outcome-specific thresholds.

Results

One hundred and forty-six women with threatened preterm labor met the inclusion criteria; of which 74 (50.7%) had a short cervix and 72 (49.3%) had a normal cervix. The group with short cervix were more likely to deliver prematurely before 37-week gestation, as well as a shorter time interval between initial presentation and delivery and delivery within 14 days from presentation (p = .0002, p = .0001, and p = .0001, respectively). Similarly, with respect to the area under the receiver operator characteristic curves, CL measurement was found to be significant for time of delivery before or after 37 weeks (p < .0001), preterm delivery before 34 (p =  .0003) and 31 (p <  .0001) weeks; and preterm delivery within 14 days from presentation (p < .0001). Cervical length measurement has a high negative predictive value ranging from 94.9 to 97.1% depending on the different CL threshold used.

Conclusions

Cervical length measurement at the time of presentation was significantly associated with the risk of preterm delivery in women presenting with threatened preterm labor and a short cervix. Cervical length measurement was also helpful in predicting time of delivery within 14 days from presentation. The negative predictive value and predictive accuracy of CL as a single measure were of significance.

Disclosure statement

No potential conflict of interest was reported by the author

Additional information

Funding

None.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.