Utility of fiberoptic bronchoscopy for difficult airway in neonates

ORCID Icon, , , , &
Pages 2754-2757 | Received 07 May 2019, Accepted 18 Sep 2019, Published online: 01 Oct 2019
 

Abstract

Background

Newborns diagnosed with craniofacial malformations or laryngeal and tracheal alterations may often need advanced airway-management for airway stabilization. Although fiberoptic bronchoscopy (FB) is currently the gold standard for difficult airway management, there is a scarcity of published data on the application of FB in newborns for intubation and controlled extubation (CE).

Objectives

This study describes a case series where FB is used for intubation and/or extubation to manage newborns with difficult airway in either urgent procedures or scheduled ones.

Methods

All FB were carried out on newborns with difficult airway in the neonatal unit over the period January 2005 to December 2018. Patient characteristics were collected from clinical reports, description of the technique from the procedure report.

Results

66 FBs were performed from a total of 40 newborns, a median age of 25 days and a weight of 3217 g. Eighteen were ex-premature babies (45%). Six (15%) had craniocervical malformations. 17 (25.7%) FBs were performed for tracheal intubation (TI), 6 in emergency situations, 34 (51.5%) for CE, and 15 (22.7%) for precise tube placement. Clearing of the airway was achieved in all cases and thus there were no failed TIs. In 32 cases (94.1%), CE was successfully performed. In 6 cases, withdrawal of the ET midprocedure was decided to postpone as 4 of these required extra treatment prior to renewed extubation attempt and 2 needed a tracheostomy. 2 patients required subsequent FB reintubation due to airway pathology. Complications during the procedure were mild desaturations (3%) and deep desaturations (7.5%).

Conclusions

FB is very safe and highly useful when performing intubation in neonates with difficult airway but is essential during extubation to avoid any risk of failure with a potentially fatal outcome. Neonatal units of tertiary hospitals should provide equipment and training to manage these neonates.

What is already known?

A failed intubation or extubation can lead to cardiac arrest and anoxic brain damage and/or to death in a neonate. Fiberoptic bronchoscopy is recommended as the safest tool for neonates with difficult airway. However, there is little concrete data published in the current literature to support the recommendations.

What is new

Fiberoptic bronchoscopy is an essential tool to avoid the risk of a failed extubation in neonates with difficult airway.

Acknowledgements

We would like to thank Gerard Laracy for his editorial assistance in the preparation of this manuscript.

Disclosure statement

No potential conflict of interest was reported by the authors.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.