Is noninvasive neurally adjusted ventilatory assistance (NIV-NAVA) an alternative to NCPAP in preventing extubation failure in preterm infants?

ORCID Icon, ORCID Icon, , , & ORCID Icon
Pages 3756-3760 | Received 08 Aug 2019, Accepted 22 Nov 2019, Published online: 02 Dec 2019
 

Abstract

Background

Prolonged use of mechanical ventilation is associated with some complications as high mortality and high morbidities as bronchopulmonary dysplasia, ventilator-associated pneumonia, and pneumothorax. However, extubation failure in preterm infants is still high (40–60%) in very low birth weight infants (VLBW). Noninvasive neurally adjusted ventilatory assistance (NIV-NAVA) is triggered by the diaphragmatic electrical activity through a nasogastric tube that synchronizes patient/ventilator respiration, cycle by cycle effectively shortening the assisted cycle trigger and the degree of ventilatory assistance, optimizing the effects of intermittent inspiratory pressure on nasal continuous positive airway pressure (NCPAP). This study aims to compare reintubation rates until 72 h after extubation in preterm infants of high risk for reintubation using NIV-NAVA or NCPAP.

Methods

A retrospective study of chart review data collection was performed in a private tertiary hospital. The study was approved by the local institutional Ethics Committee. We included infants considered at high risk of reintubation (BW < 1000 grams; use of invasive mechanical ventilation (IMV) for at least 7 days; or previous extubation failure episode) and compared the two groups according to the type of respiratory support after extubation: (1) NCPAP (n = 32); or (2) NIV-NAVA (n = 17). Demographics data were collected, the primary outcome was reintubation rate until 72 h after extubation. Secondary outcome was time to reintubation, BPD rate, IVH grade ≥ III, pneumothorax and death.

Results

There was no difference between both groups in demographic data. The reintubation rate decreased significantly in the NIV-NAVA group compared to NCPAP (50.0–11.7, p < .02) despite the significantly higher length of invasive mechanical ventilation (IMV) before extubation attempt in NIV-NAVA group (12.4 versus 5.5 days, p < .04). There was no difference between both groups in secondary outcomes.

Conclusions

In this small retrospective cohort study, the use of NIV-NAVA as postextubation strategy was effective in reducing extubation failure within 72 h in preterm infants when compared to traditional NCPAP.

Disclosure statement

No potential conflict of interest was reported by the authors.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.