ABSTRACT
Introduction: Neurosurgical devices are increasingly used. With it, neurosurgical device-related infections gain relevance. As biofilms are involved in implant-associated infections the diagnosis and treatment is challenging and requires specific anti-biofilm concepts and management algorithms.
Areas covered: The literature concerning the management of neurosurgical device-associated infections is scarce and heterogeneous treatment concepts are discussed, but no standardized diagnostic and treatment procedures exist. Therefore, we emphasize extrapolating management strategies predominantly from orthopedic device-associated infections, where the concept is better established and clinically validated. This review covers infections associated with craniotomy fixation devices, cranioplasties, external ventricular and lumbar drainages, internal shunts and neurostimulators.
Expert commentary: Sonication of the removed implants significantly improves microbiological diagnosis. A combined surgical and antimicrobial management is crucial for successful treatment: appropriate surgical intervention is combined with prolonged anti-biofilm therapy of usually 12 weeks. In selected patients, new treatment algorithms enable cure of neurosurgical device-associated infections without implant removal or with a one-stage implant exchange, considerably improving the quality of patient lives.
Declaration of interest
The authors have no relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript. This includes employment, consultancies, honoraria, stock ownership or options, expert testimony, grants or patents received or pending, or royalties.