169
Views
1
CrossRef citations to date
0
Altmetric
Technical Papers

Assessment of Activation on Level L3 of the Tokamak Building due to the ITER Tokamak Cooling Water System

ORCID Icon, , , &
Pages 458-465 | Received 26 Jun 2018, Accepted 08 Apr 2019, Published online: 09 May 2019
 

Abstract

The ITER fusion reactor is being built to demonstrate the feasibility of fusion power and will be the largest tokamak in the world. The tokamak cooling water system (TCWS) will extract the heat generated during operations and includes large amounts of piping and equipment such as pumps and heat exchangers (HXs) that are located in a large shielded region on level L3 of the tokamak building. During operation, water in the TCWS will be activated by plasma neutrons and then flow into this shielded region. The activated coolant will in turn activate the steel in the TCWS during operation and result in an activation gamma source and radiation responses that must be assessed to inform equipment selection and maintenance schedules.

The activation of materials in the shielded region of level L3 was assessed at several decay times and for different equipment options using the Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite. The ORNL SDDR code suite implements the rigorous two-step method using the Multi-Step Consistent Adjoint-Driven Importance Sampling (MS-CADIS) method to create effective neutron variance reduction parameters for the photon response of interest. Two different HX designs, shell and tube and shell and plate, were considered, as well as the impact of cobalt impurities in steel equipment.

Acknowledgments

This manuscript has been authored by UT-Battelle, LLC, under contract DE-AC05-00OR22725 with the U.S. Department of Energy (DOE). The U.S. government retains and the publisher, by accepting the article for publication, acknowledges that the U.S. government retains a nonexclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for U.S. government purposes. DOE will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).

The views and opinions expressed herein do not necessarily reflect those of the ITER Organization. This work was supported by the US ITER Organization. This research used resources of the Compute and Data Environment for Science at ORNL, which is supported by the DOE Office of Science under contract number DE-AC05-00OR22725.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 596.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.