285
Views
30
CrossRef citations to date
0
Altmetric
Original Articles

Detection of Phosphatidylethanol (PEth) in the Blood of Drivers in an Alcohol Ignition Interlock Program

, , , , , & show all
Pages 136-141 | Received 24 Jun 2010, Accepted 28 Nov 2010, Published online: 04 Apr 2011
 

Abstract

Objective: The rate of failed interlock blood alcohol content (BAC) tests is a strong predictor of recidivism post-interlock and a partial proxy for alcohol use. Alcohol biomarkers measured at the start of an interlock program are known to correlate well with rates of failed BAC tests over months of interlock use. This study evaluates 2 methods of measuring low blood levels of the biomarker phosphatidylethanol (PEth). PEth is a 100 percent alcohol-specific biomarker and strongly intercorrelated with several independent indicators of drinking driving risk, including 8 other biomarkers, 3 psychometric assessments, and the rate of failed interlock BAC tests during many months of interlock use. Does a more sensitive method of measuring PEth at program entry detect drinking even among those who subsequently log no failed interlock tests?

Methods: In a sample of 281 driver blood samples, PEth was measured by both high-performance liquid chromatography (HPLC) and liquid chromatography tandem mass spectrometry (LCMSMS) in order to compare sensitivity and accuracy. The average rate of failed interlock BAC tests was the criterion measure for marker sensitivity. LCMSMS, calibrated to detect low levels of drinking as a possible measure of abstinence violation, was judged relative to the standard HPLC assay for PEth measured up to 4 μmol/L.

Results: The 2 methods showed a good quantitative relationship (r2> .86). LCMSMS detected positive PEth levels in samples that were below the limit of detection of the HPLC method. PEth measured by LCMSMS was positive for a higher proportion of driving under the influence (DUI) offenders who logged zero failed interlock BAC tests than were detected by HPLC.

Conclusion: Although HPLC is the widely used standard for measuring PEth in clinical alcoholism samples, the LCMSMS method, when calibrated to detect trace amounts of the major component of PEth, can detect abstinence levels of alcohol near zero intake and still correlate strongly with other indicators related to alcohol use and road safety.

ACKNOWLEDGMENT

This work was supported by two grants from the National Institute on Alcohol Abuse and Alcoholism: one to study Alcohol Interlocks and Biomarkers (US NIH/NIAAA 5 R01 AA014206) and the other for an Impaired Driving Center (US NIH/NIAAA P20 AA017831).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 331.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.