239
Views
10
CrossRef citations to date
0
Altmetric
Original Articles

Reducing Respirator Fit Test Errors: A Multi-Donning Approach

, , &
Pages 391-399 | Published online: 23 Oct 2007
 

Abstract

As a continuation of recent studies to assess the accuracy of existing fit test methods, a multi-donning approach to fit testing is presented. As an example of that approach, a multi-donning quantitative fit test for filtering-facepiece respirators is presented and analyzed by comparing its error rates with those of the single-donning approach of current fit test methods. That analysis indicates the multi-donning fit test has the potential to reduce both the alpha error and the beta error to half that of single-donning fit tests. The alpha error is the error of failing a respirator that should pass; the beta error is the error of passing a respirator that should fail. Lowering fit test error rates for filtering-facepiece respirators is important because fit testing is an essential means of helping assure that an individual has selected an adequately fitting respirator. To reduce the alpha and beta error inherent in current fit test methods, the proposed fit test for filtering-facepiece respirators incorporates five donnings of the facepiece, unlike the single donning of existing fit test methods. The analysis presented here indicates that the multiple-donning approach reduces the element of chance in the fit test result and thereby increases the consistency and accuracy of the fit tests. The time to conduct the multi-donning test can approximate the time for current, single-donning tests by shortening the time the respirator is worn after each donning to about 10 sec. And, unlike current fit tests for filtering-facepieces that measure only faceseal leakage, the example multiple-donning fit test considered here is based on a measurement of total leakage (faceseal plus filter). Utilizing total respirator leakage can result in simpler quantitative fit test instrumentation and a fit test that is more relevant to the workplace. Further trials with human subjects are recommended in order to validate the proposed multi-donning approach.

Notes

A A qualitative test relying on the subject to acknowledge tasting the test agent.

B A quantitative test using the size fraction of ambient aerosols least penetrating to respirator filter and conducted with the TSI PortaCount Plus and the TSI N95-Companion fit test instruments.

A Where the summation is over all subject/model combinations with an inadequate fit. (i.e., points below the acceptability line of ).

B Where the summation is over all subject/model combinations with an adequate fit. (i.e., points above the acceptability line of ).

A Where the summation is over all subject/model combinations with an inadequate fit (i.e., points below the acceptability line of ).

B Where the summation is over all subject/model combinations with an adequate fit (i.e., points above the acceptability line of ).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.