764
Views
20
CrossRef citations to date
0
Altmetric
Original Articles

Real-Time Fit of a Respirator during Simulated Health Care Tasks

, , &
Pages 563-571 | Published online: 27 Aug 2012
 

Abstract

Fit is an important but difficult-to-predict feature of respirator performance. This study examined a new approach to measuring respirator performance using two continuous direct-reading particle-counting instruments in a simulated health care workplace. A pilot test was conducted with eight experienced health care professionals who passed a traditional quantitative fit test before performing three randomized 10-min health care scenarios (patient assessment [PA], IV treatment [IV], and wound care [WC]). Two TSI Portacount Plus (Model 8020) with N95 Companion (Model 8095) instruments were used to continuously measure 1-sec ambient particle concentrations inside and outside the respirator facepiece. A simulated workplace protection factor (SWPF) was calculated by dividing outside by inside concentrations. Data were log transformed and examined using analysis of variance (ANOVA) between subjects, scenario types, and scenario order. The GM SWPF for the eight subjects, three scenarios per subject, ranged from 172 to 1073 (GSD 1.7 to 3.5) and was significantly different for each subject. A multi-way analysis of variance showed no difference between the three scenario types (PA, IV, WC). There were differences by the order in which scenarios were performed: the third scenario SWPF was significantly different and higher than that of the first and second scenarios. All subjects passed the initial quantitative fit test with a fit factor of at least 100. Five subjects had fit factors greater than 200 and GM scenario SWPFs greater than 400. Three participants with initial fit factors less than 200 had GM scenario SWPFs ranging from 132 to 326. This pilot test demonstrates that it is possible to evaluate instantaneous respirator fit using two quantitative fit test instruments in a simulated health care environment. Results suggest that an initial fit test may be predictive of fit during simulated tasks and that one scenario may be adequate for measuring a simulated workplace protection factor.

[Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a video for subject D activities overlaid with simulated workplace protection factor data.]

ACKNOWLEDGMENTS

This project was supported in part by a contract from 3M supplemented by internal research funds (Lisa M. Brosseau). All activities were a collaborative effort of 3M and University of Minnesota investigators and fulfilled research requirements for a master's degree (Jessica Hauge). We thank Timothy Teasdale, Michael Luinenburg, Mary Jamieson, Philip Eitzman, and Susan Danisch at 3M for their advice and assistance with this project. We also thank Martin Cohen from the University of Washington for his assistance in creating the video with data overlay.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.