1,085
Views
71
CrossRef citations to date
0
Altmetric
Departments

Creatinine and Specific Gravity Normalization in Biological Monitoring of Occupational Exposures

, , , , , & show all
Pages 123-129 | Published online: 05 Sep 2014
 

Abstract

Reference values for the biological monitoring of occupational exposures are generally normalized on the basis of creatinine (CR) concentration or specific gravity (SG) to account for fluctuations in urine dilution. For instance, the American Conference of Governmental Industrial Hygienists (ACGIH®) uses a reference value of 1g/L for CR. The comparison of urinary concentrations of biomarkers between studies requires the adjustment of results based on a reference CR and/or SG value, although studies have suggested that age, sex, muscle mass, and time of the day can exert non-negligible influences on CR excretion, while SG appears to be less affected. The objective of this study was to propose reference values for urinary CR and SG based on the results of samples sent for analysis by occupational health practitioners to the laboratory of the Occupational Health and Safety Research Institute of Québec (IRSST). We analyzed a database containing 20,395 urinary sample results collected between 1985 and 2010. Linear mixed-effects models with worker as a random effect were used to estimate the influence of sex and collection period on urinary CR and SG. Median CR concentrations were 25–30% higher in men (1.6 g/L or 14.4 mmol/L) than in women (1.2 g/L or 10.2 mmol/L). Four percent of the samples for men and 12% for women were below the acceptable threshold for CR (4.4 mmol/L). For SG, 5% of samples for men and 12% for women were below the threshold of 1.010. The difference in SG levels between sexes was lower than for CR, with a median of 1.024 for men compared to 1.020 for women. Our results suggest that the normalization of reference values based on a standard CR value of 1 g/L as proposed by the ACGIH is a conservative approach. According to the literature, CR excretion is more influenced by physiological parameters than SG. We therefore suggest that correction based on SG should be favored in future studies involving the proposal of reference values for the biological monitoring of occupational exposures.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.