Evaluation of the well mixed room and near-field far-field models in occupational settings

, &
Pages 694-702 | Published online: 28 Aug 2017
 

ABSTRACT

Drawing appropriate conclusions about a scenario for which the exposure is truly unacceptable drives appropriate exposure and risk management, and protects the health and safety of those individuals. To ensure the vast majority of these decisions are accurate, these decisions must be based upon proven approaches and tools. When these decisions are based solely on professional judgment guided by subjective inputs, however, they are more than likely wrong, and biased, underestimating the true exposure.

Models have been shown anecdotally to be useful in accurately predicting exposure but their use in occupational hygiene has been limited. Possible reasons are a general lack of guidance on model selection and use and scant model input data. The lack of systematic evaluation of the models is also an important factor.

This research is the second phase of work building upon the robust evaluation of the Well Mixed Room (WMR) and Near Field Far Field (NF-FF) models under controlled conditions in an exposure chamber,Citation[5] in which good concordance between measured and modeled airborne concentrations of three solvents under a range of conditions was observed. In real world environments, the opportunity to control environmental conditions is limited and measuring the model inputs directly can be challenging; in many cases, model inputs must be estimated indirectly without measurement. These circumstances contribute to increased model input uncertainty and consequent uncertainty in the output. Field studies of model performance directly inform us about how well models predict exposures given these practical limitations, and are, therefore, an important component of model evaluation.

The evaluation included ten diverse contaminant-exposure scenarios at five workplaces involving six different contaminants. A database of parameter values and measured and modeled exposures was developed and will be useful for modeling similar scenarios in the future.

Funding

This research was made possible by funding under NIOSH 1R010H010093-01A2.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.