Manikin-based size-resolved penetrations of CE-marked filtering facepiece respirators

ORCID Icon, , , &
Pages 965-974 | Published online: 30 Nov 2017
 

ABSTRACT

The purpose of this manikin-based study was to determine the percentage penetrations of nine CE-marked filtering facepiece respirator models (two samples from each) from filtering classes FFP1, FFP2, and FFP3 and to demonstrate by an independent measurement method the disadvantages and shortcomings of the currently valid European Norm (EN 149:2001) for filtering facepieces. All of the filtering facepieces were evaluated size-selectively in an experimental chamber using charge-neutralized monodisperse ammonium sulfate in 9 sizes ranging from 20–400 nm of count median diameter (CMD) under flowrate of 95 L/min. The results were then compared to the previous study concerning penetrations of 47-mm diameter filters cut from the filtering material of identical filtering facepieces. Although these two experimental methods for measuring penetrations of filtering materials from filtering facepieces are in good agreement (R2 = 0.91), the results show within-respirator variations in all three filtering classes (5.5–19.3% for all FFRs in FFP1, 2.8–8.5% in FFP2, and 0.1–2.8% in FFP3). The most penetrating particle size (MPPS) in this study was found to be in the range of 25–65 nm (CMD), which is in agreement with the range of 30–60 nm found in the previous study. Moreover, 7 out of 9 FFR models reached higher penetrations from manikin-based respirator measurements than during measurements of filters from the respective respirators. Furthermore, penetration levels increased up to ∼50% when the respirator was not sealed around the face of the manikin, indicating that the real protection level provided by these filtering facepieces may be even lower if the respirator does not fit perfectly. Considering that poor filtration efficiency and poor fit may increase under real work conditions, the particle penetration is even higher than was found in this study. Therefore, the CE-marked respirators examined in this study may not be efficient in providing the expected level of protection for workers exposed to nanoparticles.

Acknowledgments

The authors thank the National Institute for Nuclear, Chemical and Biological Protection, v.v.i. (71 Kamenná, 262 31 Milín, Czech Republic) for providing the test chamber for purposes of this study. The authors thank Kayleigh Kavanagh, BSc, for her language corrections of the manuscript.

Funding

This work was supported by the European Union 7th framework program HEXACOMM FP7/2007–2013 under grant agreement N° 315760 and by the Ministry of Interior of the CR under grant No. VF2011201513.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 148.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.