Publication Cover
LEUKOS
The Journal of the Illuminating Engineering Society
Volume 19, 2023 - Issue 1
330
Views
1
CrossRef citations to date
0
Altmetric
Articles

Effect of Correlated Color Temperature and S/P-ratio of LED Light Sources on Reaction Time in Off-axis Vision and Mesopic Lighting Levels

ORCID Icon, ORCID Icon, , , & ORCID Icon
Pages 4-15 | Received 22 Dec 2020, Accepted 17 Aug 2021, Published online: 05 Oct 2021
 

ABSTRACT

The increasing replacement of traditional lamps by LED technology opens the door to research into visual performance under their multiple possible spectral power distributions. The correlated color temperature and S/P-ratio are considered parameters characterizing the spectrum of a light source. The lack of firm conclusions motivates the analysis in this work of the influence of LED spectrum, which is defined by the correlated color temperature and S/P-ratio, on a representative night-driving task, visual reaction time. A two-channel and four primaries photostimulator was used as set-up for measuring reaction time in off-axis vision, at mesopic illumination conditions and for a range of stimulus contrasts. The experimental conditions included a wide range of correlated color temperatures, ranging from 1870 to 6350 K, and different S/P-ratios for the same temperature. A total of 16 young subjects participated in the experiments. The results show significant shorter reaction times for those conditions in which the spectrum has greater short-wavelength content. This is corroborated by the greater stimulation of rods and S-cones obtained in the calculation of their excitation level. However, the definition of the spectrum using the correlated color temperature and S/P-ratio does not equally define the results obtained. For the same temperature, a higher S/P-ratio provides lower reaction time values, but for the same S/P ratio reaction time is independent of the temperature. LED light sources with high short-wavelength content provide faster response on the basis of a greater excitation of rods and S-cones. The S/P-ratio is the best parameter to justify the effect of spectrum on reaction time, as considers the spectral sensitivity of the visual system in its calculation.

Acknowledgments

The research team would like to thank all subjects for their participation.

Disclosure statement

No potential conflict of interest was reported by the authors.

Additional information

Funding

This work was supported by the Spanish Ministerio de Economía y Competitividad (MINECO) (FIS2016-78037-P) and the Fondo Social Europeo, Iniciativa de Empleo Juvenil and Junta de Castilla y León.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 134.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.