Publication Cover
Structure and Infrastructure Engineering
Maintenance, Management, Life-Cycle Design and Performance
Volume 12, 2016 - Issue 1
148
Views
2
CrossRef citations to date
0
Altmetric
Articles

Evaluation and refinement of closely spaced buildings’ performance under near-fault ground motions

&
Pages 21-44 | Received 17 Apr 2014, Accepted 13 Nov 2014, Published online: 08 Jan 2015
 

Abstract

This paper investigates the seismic behaviour of closely spaced fixed-base and isolated building structures in near-fault (NF) zones. Seismic pounding of fixed-base structures is considered at different heights, being from one or both opposite sides and at different seismic gap width. The response evaluation results of fixed-base buildings drive towards providing limited, but adequate, seismic gaps to perform seismic isolation. This aims at reducing structural responses with no seismic pounding under limited gaps, minimising the possible damage repair and diminishing the needed maintenance works due to strong NF earthquakes. To achieve that untraditionally, the paper presents a recently proposed seismic isolation system, named roll-in-cage (RNC) isolator, as a non-traditional solution to avoid direct seismic pounding of isolated buildings with their surrounding adjacent structures. It was found that the RNC isolator’s buffer mechanism is able to draw down any possible pounding of the isolated superstructure to be within the isolator solid limits. This entirely prevents direct structure-to-structure pounding but on the account of amplifying its acceleration and drift responses. However, such amplified responses might lead to only minor or moderate structural damage under sever NF earthquakes with 1.20g peak ground acceleration. Nevertheless, such damage could be avoided entirely using stiffer RNC isolators to achieve reduction of seismic response up to 69.0% under the same severe loading conditions and limited seismic gaps with no seismic pounding. Consequently, the RNC isolator could be an efficient solution for aseismic design in NF zones considering limited seismic gaps.

Notes

Additional information

Funding

The first author gratefully acknowledge the financial support of Professor José Rodellar, the director of CoDAlab laboratory and research group at the Technical University of Catalonia, Barcelona, Spain, to entirely accomplish the experimental validation of the RNC isolator.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 298.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.