BWR Loss-of-Coolant Accident Tests at ROSA-III with High Temperature Emergency Core Coolant Injection

, &
Pages 169-179 | Received 03 Mar 1987, Published online: 15 Mar 2012
 

Abstract

The effects of emergency core coolant (ECC) temperature on the performance of the emergency core cooling system (ECCS) during a loss-of-coolant accident (LOCA) of a boiling water reactor (BWR) were investigated experimentally using the Rig of Safety Assessment (ROSA)-III integral test facility. The ECC temperature had no direct influence on the ECCS core cooling performance, since ECC became nearly saturated before reaching the core irrespective of the initial temperature, however, had indirect effects by changing the vessel pressure response. The ECCS injection timings and flow rates, and the core inlet flooding behavior were affected. The measured peak cladding temperature (PCT) was not affected by the ECC temperature for both large (200%) and small (5%) break tests.