An inverse hygrothermal model for multi-zone buildings

&
Pages 510-528 | Received 09 Jul 2015, Accepted 13 Oct 2015, Published online: 27 Nov 2015
 

Abstract

The dynamic hygrothermal behaviour of existing buildings can be characterized using data-driven models that are established via system identification techniques. However, most of the time the identification problem is difficult to solve for multi-zone buildings due to high dimensionality of the model and poor excitation in the training data. In addition, building thermal and moisture dynamics are coupled and simultaneous identification of the coupled model is challenging. This paper presents a simplified one-way coupled inverse model to capture the building thermal and moisture dynamics where the impact of space moisture on the building thermal response is neglected. This simplification enables the thermal and moisture sub-models to be estimated sequentially which reduces the computation complexity and improves model identifiability. Both thermal and moisture sub-models adopt a physically based approach in which moisture interactions between different zones are neglected while the inter-zonal thermal interactions are captured. A 3-step procedure is developed to reduce the problem dimension in identifying the thermal sub-model. As a case study, the overall approach was applied to model a medium-size commercial building with nine thermal zones from measured data and the estimated models were validated for different periods of time during a cooling season.

Disclosure statement

No potential conflict of interest was reported by the authors.

Nomenclature

Awall=

total wall area within a zone (m2 or ft2)

C=

thermal/moisture capacitance (kJ/K or Btu/°F/kg or lb)

cp,air=

air specific heat (kJ/kg-K or Btu/lb- °F)

CS=

coupling matrix for the zones

J=

sensitivity matrix

M=

information matrix

msup=

supply air mass flow rate (kg/s or lb/hr)

Occup=

number of occupants within a zone

Pwhole,bui=

whole building power (kW or Btu/hr)

PHVAC=

HVAC system power (kW or Btu/hr)

Qsol,ext=

solar radiation absorbed on the external walls (kW or Btu/hr)

Qsol,trans=

solar radiation transmitted through the windows (kW or Btu/hr)

Qgain,rad=

radiative internal heat gains (kW or Btu/hr)

Qgain,conv=

convective internal heat gains (kW or Btu/hr)

Qsen=

sensible cooling/heating to the space (kW or Btu/hr)

R=

thermal/moisture resistance (K-s/kJ or °F-hr/Btu / s/kg or hr/lb)

RH=

relative humidity (%)

Tgrd=

ground temperature (°C or °F)

Tsup=

supply air temperature (°C or °F)

Tzone,adj=

air temperature of the adjacent zone (°C or °F)

u=

input vector

U=

excitation data

w=

disturbance vector

w=

water content (kg water/kg air or lb water/lb air)

wwall=

wall water content (kg water/kg material or lb water/lb material)

woccup=

moisture generation rate per occupant (kg water/s or lb water/hr)

x=

state vector

y=

output vector

δ=

parameter perturbation level

σ=

model error standard deviation

θ=

estimate parameters

ξ=

slope of the wall material sorption curve

ψ=

slope of the air relative humidity to humidity ratio curve

Δwgen=

zone internal moisture gain (kg/s or lb/hr)

Δwvent=

moisture gain/removal due to mechanical cooling (kg/s or lb/hr)

Subscripts/superscripts=
amb=

ambient condition

avgd=

averaged value

cal=

calculated/estimated matrix

d=

discrete version of the state-space matrices

deep=

deep layer in the EMPD method

GA=

generated points in global analysis

inf=

infiltration

moi=

moisture-related variables/matrices

norm=

normalized matrix

surf=

surface layer in the EMPD method

wall=

wall-related variables

zone=

zone air condition

σ=

switching mode in the moisture model

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 297.00 Add to cart

* Local tax will be added as applicable