351
Views
7
CrossRef citations to date
0
Altmetric
Original Articles

Effect of ionising radiation treatment on the specific migration characteristics of packaging–food simulant combinations: effect of type and dose of radiation

, &
Pages 686-694 | Received 04 Nov 2010, Accepted 16 Jan 2011, Published online: 11 Mar 2011
 

Abstract

Migration levels of acetyl tributyl citrate (ATBC) plasticiser from polyvinyl chloride (PVC) film into the European Union specified aqueous food simulants (distilled water, 3% w/v acetic acid and 10% v/v ethanol) were monitored as a function of time. Migration testing was carried out at 40°C for 10 days. Determination of the analyte was performed by applying an analytical methodology based on surfactant (Triton X-114) mediated extraction prior to gas chromatographic-flame ionisation detection. PVC cling film used was subjected to ionising treatment with a [60Co] source, as well as to electron-beam irradiation at doses equal to 5, 15 and 25 kGy, with the aim to compare the effect of type and dose of radiation on the specific migration behaviour of PVC. Equilibrium concentrations of acetyl tributyl citrate into the aqueous solvents covered the ranges 173–422 µg l−1 and 296–513 µg l−1 for gamma- and electron-irradiated PVC, respectively. Hence, e-beam irradiation resulted in significantly higher ATBC migration compared with gamma treatment. The highest extraction efficiency of the 10% ethanol solution was common in both gamma and e-beam treatments; distilled water demonstrated the lowest migration. Gamma-irradiation at intermediate doses up to 5 kGy produced no statistically significant (p > 0.05) effect on ATBC migration into all three aqueous simulants; however, this does not apply for high-energy electrons. Both ionising treatments were similar in that they resulted in statistically significant (p < 0.05) differences in plasticiser migrating amounts between non-irradiated and irradiated at doses of 15 and 25 kGy samples. Gamma-radiation did not affect the kinetics of plasticiser migration. On the contrary, electron-beam radiation produced shorter equilibration times for all food-simulating solvents tested at 40°C. The above values regarding ATBC migration into aqueous food simulants are far below the European Union restriction (1 mg kg−1 body weight) for both types of ionising radiation. Thus, PVC cling film may be used in food irradiation applications in contact with aqueous foodstuffs.

Acknowledgements

This study was funded by the General Secretariat of Research and Technology (GSRT) of Greece within the framework of the PENED 2001 Program of the Greek Ministry of Development. The authors gratefully acknowledge this financial support. Furthermore, they wish to acknowledge technical assistance provided by Dr Μ. Stahl at the Federal Research Center for Nutrition and Food (Germany), as well as by Dr H. Alkan at the GAMMA-PAK AS plant (Turkey).

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 799.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.