420
Views
1
CrossRef citations to date
0
Altmetric
Corrigendum

Construction and exploration of pollutant consumption oxygen equivalent treatment costs in municipal wastewater treatment plantsFootnote

, &
This article refers to:
Construction and exploration of pollutant consumption oxygen equivalent treatment costs in municipal wastewater treatment plants

Published Online: 28 April 2014

In the original online version of the article “Construction and exploration of pollutant consumption oxygen equivalent treatment costs in municipal wastewater treatment plants” (DOI: 10.1080/19443994.2013.803314), the authors wish to make the following corrections in the figures (marked in bold/underlined).

4.1. Calculation

Table 1

The influent and effluent qualities and treatment cost per cubic meter of wastewater in MWTPs

In Table 1

0.57 should replace 0.44 which was incorrect.

0.73 should replace 0.57 which was incorrect.

Table 2

Pollutant consumption oxygen equivalents in MWTPs

In Table 2

0.57 should replace 0.44 which was incorrect.

2.97 should replace 1.68 which was incorrect.

0.73 should replace 0.57 which was incorrect.

2.31 should replace 1.41 which was incorrect.

4.2. Feasibility analysis of PCOETC

The left figure is correct and should replace right figure which was incorrect.

Firstly, the PCOE per cubic meter of wastewater (or unit PCOE) in the MWTPs in southwest China lies mainly from 180 to 500 g/m3 (Fig. 1). PCOETC is mainly from 1.50 to 3.0 yuan/kg, and its mean value is about 2.24 yuan/kg.

2.24 should replace 2.17 which is incorrect.

Secondly, according to the case study of 18 MWTPs in southwest China, a significant inverse relation is found between unit PCOE and PCOETC in the MWTPs (Fig. 1). The higher the unit PCOE value, the lower the PCOETC value, and vice versa. On fitting the data, the PCOETC model we obtained is C = 75.382Q−0.6202.

C = 75.382Q−0.6202 should replace C  =  59.349Q−0.5836 which was incorrect.

5. Application of PCOETC

In view of the statistical data, the average values of P(Pm) and Q (Qm) of the 18 MWTPs China in 2010 are 0.68 yuan/m3 and 353.68 g/m3, respectively. In light of Tables 3 and 4, the running costs of the MWTPs are evaluated by PCOETC.±20% of the treatment costs per cubic meter of wastewater(Pm) and PCOE(Qm) are considered as the value for the evaluation standard of small, medium, and large values. The results show that the treatment costs per cubic meter of wastewater of 13 of the MWTPs is normal, that of 2 of them is low, and 3 of them is high (Table 5).

0.68 should replace 0.69 which was incorrect.

13 should replace 14 which was incorrect.

3 should replace 2 which was incorrect.

Table 5

The evaluation results of applying PCOETC

In Table 5

0.54Pm = 0.68 ≤ 0.81 should replace 0.55 < Pm  =  0.69 < 0.82 which was incorrect.

0.57 should replace 0.44 which was incorrect.

medium should replace small which was incorrect.

high should replace normal which was incorrect.

0.73 should replace 0.57 which was incorrect.

6. Conclusions

The PCOE formula is deduced using the fact that wastewater pollutant indicators such as COD, BOD, SS, NH3-N, TN, and TP have some relation to oxygen consumption. Thus, the PCOE formula is derived: T  = U +  1.97X  +  15.81Z. On this basis, we further build the mathematical model for PCOETC (C = 75.382Q−0.6202). The results show that PCOE (Q) and PCOETC (C) have a significant inverse relation based on the study of practical examples from 18 MWTPs in southwest China (Fig. 1). Overall, the higher the PCOE value, the lower the PCOETC value, and vice versa. This proves that PCOETC is a reasonable and correct parameter to use, and that it can be used as the evaluation parameter for the running costs of MWTPs.

C = 75.382Q−0.6202 should replace C  =  59.349Q−0.5836 which was incorrect.

Finally, the running costs of 18 MWTPs are evaluated according to the PCOETC theory. The results obtained show that the treatment costs per cubic meter of wastewater of 13 MWTPs are normal, that of 2 are low, and that of 3 are high. PCOETC can effectively evaluate the running cost of a MWTP together with PCOE and the treatment costs per cubic meter of wastewater. This method is much more scientific than the commonly used statistical indicator (i.e. the treatment cost per cubic meter of wastewater). This has important significance in the operation and management of MWTPs.

13 should replace 14 which was incorrect.

3 should replace 2 which was incorrect.

Notes

* doi number of the original article is 10.1080/19443994.2013.803314

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.