74
Views
0
CrossRef citations to date
0
Altmetric
Original Articles

Comparison of the 90Y-labelled glass microspheres liver radioembolisation dosimetry with the estimated dosimetry obtained from pre-treatment 99mTc-MAA SPECT images reconstructed with and without attenuation correction

ORCID Icon, ORCID Icon, ORCID Icon & ORCID Icon
Pages 651-659 | Received 15 Dec 2017, Accepted 22 Oct 2018, Published online: 26 Nov 2018
 

ABSTRACT

90Y-labelled glass microspheres liver radioembolisation is an effective treatment for unresectable hepatic tumours. Its treatment planning is based on 99mTc-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT) imaging. However, photons interaction with human tissues may significantly compromise the accuracy of radioactivity quantification in nuclear medicine. The aim of this work is to evaluate the impact of a patient-specific attenuation correction on pre-treatment 99mTc-MAA SPECT images and, consequently, on the estimation of radioembolisation dosimetry. The methodology developed for attenuation correction was firstly validated on phantom models. Following this, a data set of eight patients was retrospectively selected from our database and the pre-treatment images were reconstructed with and without attenuation correction. Then, the liver dosimetry maps were estimated and compared with the liver dosimetry maps estimated from the post-treatment 90Y positron emission tomography images. Results show that the attenuation corrected phantom images were greatly improved, originating higher contrast, signal-to-noise ratio and contrast-to-noise ratio comparatively to non-attenuation corrected images. Attenuation corrected clinical pre-treatment images significantly increase the agreement, measured with the intraclass correlation coefficient, between predictive and post-treatment dosimetry maps comparatively to the non-attenuation corrected ones (Wilcoxon test, p = 0.008). In conclusion, a statistically significant increase in the agreement was achieved; however, poor correlation is still observed at the single-voxel level in some patients. Thus, future research should be addressed to investigate the reasons of this and manage to optimise the agreement between the predictive and post-treatment dosimetry.

Acknowledgments

We gratefully thank professors Lidia S. Ferreira, Enrico Maglione and M. Gabriella Signorini for their sincere advice during these months. Moreover, we wish to sincerely acknowledge all the technical staff at the Nuclear Medicine Radiopharmacology Department, Champalimaud Center for the Unknown, Champalimaud Foundation, Lisbon, for their dedication and passion, without whom all data would have not been possible to be acquired.

Disclosure statement

No potential conflict of interest was reported by the authors.

Ethics

All patients attending the Champalimaud Centre for the Unknown signed informed written consent as per local Ethics Committee guidelines. The retrospective analysis was completely blind of patient identification.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access
  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart
* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.