An alternative method for measuring air-handling unit static pressure following ASHRAE Standard 37: Scenario 1—horizontal ducts with elbows (RP-1581)

&
Pages 385-397 | Received 20 Jan 2015, Accepted 19 Jan 2016, Published online: 24 Mar 2016
 

Abstract

ASHRAE Standard 37 (ASHRAE 2005) describes the air-side testing setup for the indoor side (i.e., air-handling unit) of a residential air-conditioning or heat pump system for energy performance testing. Furthermore, ASHRAE Standard 37 requires a straight downstream duct that forms a vertical test section of a specified length based on the air-handling unit outlet geometry for measuring the outlet static pressure. A potential problem is that adding this duct to the unit may result in an overall test apparatus height that exceeds psychrometric test room dimensions. One possible solution investigated in this project is to create a horizontal test section by the addition of an elbow placed after the unit. The air-handling unit outlet static pressure can then be measured in this horizontal test section, which has the same length requirements as that specified by ASHRAE Standard 37 for the vertical section. This horizontal duct orientation with an elbow is referred to as Scenario 1, while a second approach based on installing a passive resistive device at the air-handling unit outlet is referred to as Scenario 2, which is the subject of a second article. Experimental tests were performed on 2-, 3-, and 5-ton units, with a variety of elbow types and orientations located at the unit exit. Experiments were also performed on the same three units with vertical test sections as described in ASHRAE Standard 37 (i.e., baseline data). Comparisons of these test results showed that ASHRAE Standard 37 can be modified to reduce testing height restrictions by using a horizontal test section providing a right-angled elbow with double-thickness turning vanes and installed at the air-handling unit outlet in a specific orientation relative to the rotating blower. Specifically, this research found that the test section height downstream of the air-handling unit outlet could be reduced by 51% to 64% for the three different units, namely 2, 3, and 5 tons. Furthermore, with regard to the height of either the vertical baseline or horizontal Scenario 1 test assembly located in a psychrometric test room, this study showed that air-handling unit tests could be successfully performed in a 9-ft-high (2.7-m) room that would otherwise require a 12-ft-high (3.7-m) room following ASHRAE Standard 37 requirements.

Additional information

Notes on contributors

Grant Wheeler

Grant Wheeler, MS, is a Systems Engineer and a Graduate Student.

Michael Pate

Michael Pate, PhD, Life Member ASHRAE, is a Professor and Director.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 78.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.