Publication Cover
Structural Heart
The Journal of the Heart Team
Volume 2, 2018 - Issue 3
98
Views
1
CrossRef citations to date
0
Altmetric
Original Research

Early and Mid-Term Outcomes of Transcatheter Aortic Valve Replacement Using the New Generation Self-Expanding Corevalve Evolut R Device

, MD, , MDORCID Icon, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD, , MD & , MD, PhD show all
Pages 229-234 | Received 20 Sep 2017, Accepted 07 Feb 2018, Published online: 27 Feb 2018
 

ABSTRACT

Background: To assess early and mid-term efficacy of transcatheter aortic valve replacement (TAVR) using the new-generation CoreValve Evolut R (Medtronic Inc., Galway, Ireland).

Methods: This is a prospective, single-center study. All consecutive patients undergoing TAVR with 23-, 26-, 29-, 34-mm Evolut R valve were included. In a secondary analysis, patients undergoing Evolut R implantation were compared using the propensity score method with a historical cohort of patients who underwent CoreValve implantation in our institution.

Results: From March 2015 to September 2017, a total of 320 patients with a median age of 81.1 years (IQR 77–84) and mean STS score of 4.9 ± 3.1% were treated. Device success was obtained in 300 patients (93.8%). Effective recapture and repositioning of the valve due to initial suboptimal deployment was accomplished in 40 patients (12.5%). Post-TAVR transthoracic echocardiogram showed a reduction in mean gradient from 49.1 ± 18.2 mmHg to 7.6 ± 0.4 mmHg (p < 0.001). Moderate paravalvular regurgitation (PVR) was observed in 4.2% patients. No patient had severe PVR. At 30-day, all-cause and cardiovascular mortality rates were 2.2% and 1.9%, respectively; disabling stroke occurred in 5 patients (1.6%). Life-threatening and major bleeding occurred in 16 (5.0%) and 42 (13.1%) patients, respectively. Pacemaker implantation rate was 12.6%. Compared with the CoreValve, Evolut R use was associated with higher device success (92.8% vs. 79.7%, p < 0.001) and lower rates of moderate or severe PVR (2.1% vs. 14.4%, p < 0.001), minor vascular complications (4.9% vs. 14.5%, p < 0.001), and pacemaker implantation (13.5% vs. 21.0%, p = 0.026).

Conclusion: In this prospective, single-center study, TAVR using the new-generation self-expanding Evolut R system, was associated with high device success rate, excellent hemodynamics, and low early complications rates.

Disclosure statements

Marco Barbanti is a consultant for Edwards Lifesciences. All other authors report no conflicts of interest.

Log in via your institution

Log in to Taylor & Francis Online

There are no offers available at the current time.

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.