2,774
Views
7
CrossRef citations to date
0
Altmetric
Review Article

A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses

ORCID Icon & ORCID Icon
Pages 31-40 | Received 20 Nov 2019, Accepted 22 Dec 2019, Published online: 20 Jan 2020

Abstract

Purpose

To compare the fit and assess the accuracy of tooth-supported single and multi-unit FDPs in cobalt chromium fabricated using different manufacturing techniques.

Materials and methods

A systematic search was performed in three databases; PubMed, Scopus, and Web of Science, using clearly specified search terms and inclusion criteria. The search yielded 1071 articles and included 18 articles in the analysis. Data regarding the fit analyses and the methods of manufacturing were extracted and the accuracy was defined as the fit result minus the pre-set cement spacer. Internal gap (IntG) was the mean of all the internal measuring points and total gap (TotG) was the mean of all measuring points (marginal, cervical, chamfer, axial, occlusal).

Results

The total gap results for fit and accuracy irrespective of manufacturing technique were 96 μm and 54 μm for single crowns, 107 μm and 54 μm for multi-unit FDPs, and 98 μm and 54 μm for both single crowns and multi-unit FDPs combined. For total gap of single crowns soft milling had the highest accuracy, for multi-unit FDPs additive manufactured restorations had the highest accuracy. With the results grouped by impression technique, the accuracy for total gap was highest for digital impressions and lower for conventional impressions.

Conclusions

Due to the inherent limitations of this systematic review, it still remains unclear what effect the manufacturing technique has on the fit of FDPs. However, the descriptive results suggest that the marginal fit of cobalt chromium FDPs is not negatively affected by the manufacturing technique.

Introduction

The manufacturing of dental restorations in cobalt-chromium alloys (CoCr) can be done using different production techniques. The traditional technique is the lost wax technique, a formative technique also called casting, but the lost wax technique is being rapidly replaced by computer-aided design/computer-aided manufacturing (CAD/CAM) techniques in dentistry and dental technology. Today, CAD/CAM techniques dominate restoration manufacturing in dentistry. For the production of CoCr, these techniques include both subtractive and additive manufacturing (AM), such as, computer numeric controlled (CNC) milling and laser melting, and the quality and fit of these restorations need to be evaluated.

An internal or marginal misfit can affect the cement junction and lead to dissolution, which may cause loosening of the restoration or secondary caries [Citation1]. The fit of a restoration is influenced by several factors, including the preparation type and taper, the amount of cement used, the pressure during cementation and the viscosity of the cement [Citation2–4]. Studies on marginal gap have debated on what distances are to be considered as clinically acceptable. Most authors agree on a mean marginal gap of approximately 100 μm [Citation1,Citation5–8]. For an internal gap, 120 μm has been reported as acceptable [Citation1,Citation7].

When assessing the internal fit of a restoration, or the cement film thickness, the fit is measured as the discrepancy at the chamfer or cervical area gap, axial discrepancy and occlusal discrepancy. It can also be presented as a mean of all the measuring areas/points [Citation9,Citation10]. To measure the fit, several techniques are used which are either destructive or nondestructive. With the destructive technique, the restoration is cemented onto dies or extracted teeth and then embedded into e.g. epoxy resin, and sectioned for analysis using a microscope [Citation11]. Nondestructive techniques can be the direct view technique, examination using an explorer with a specified radius, the silicone or impression replica technique, micro-computed tomography (micro CT), and the optical three-dimensional (3D) scanning technique [Citation7,Citation12–16].

Studies on the fit of restorations report the distance between the tooth and restoration and use both precision and accuracy interchangeably as the term for fit. However, the accuracy of a manufacturing technique is the closeness of the produced physical object to the virtual object or a master object and the precision of a manufacturing technique is the closeness of the results of repeated manufacturing. Accuracy has been defined as the deviation from the original object and precision as the accuracy of repeated measurements [Citation17]. Precision has also been defined as the ability of a machine tool or manufacturing process to produce a component to close tolerances [Citation18]. In regard to these definitions, accuracy can be seen as the closeness of the fit of a dental restoration to the aimed fit, and precision as a measurement of the reliability of a machine or a manufacturing technique. So, in order to measure the accuracy of a tooth-supported fixed dental prosthesis (FDPs), the settings for the marginal and internal cement spacer must be provided and used to compare with the fit results. Nevertheless, discussions regarding the cement spacer settings are uncommon in the literature and several studies on precision and accuracy of tooth-supported FDPs fail to provide the settings in the manuscript or compares groups with different spacer settings without taking the spacer into consideration when drawing conclusions.

This systematic review will focus on studies evaluating the fit of tooth-supported fixed prostheses in CoCr produced with different manufacturing techniques, with clearly defined spacer settings of the aimed cement space.

Aim

To compare the fit and assess the accuracy of tooth-supported single and multi-unit FDPs in CoCr fabricated using different production techniques.

Material and methods

The present study followed the PRISMA statement for transparent reporting of systematic reviews and meta-analyses [Citation19].

Search strategy

The electronic searches were performed on 31 Oct 2017 in three databases: PubMed, Scopus and Web of Science, and limited to English, Swedish, Danish and Norwegian languages. The searches and terms were:

Search pubmed 2017-10-31

((((((FDP[Title/Abstract] OR fixed partial denture[Title/Abstract] OR FPD[Title/Abstract]))) OR (((prosthesis[Title/Abstract] OR prostheses[Title/Abstract])) AND ((Dental OR dentistry)))) OR ((crown[Title/Abstract] OR crowns[Title/Abstract] OR bridge[Title/Abstract] OR bridges[Title/Abstract])))) AND ((cobalt chromium[Title/Abstract] OR cobalt chrome[Title/Abstract] OR CoCr[Title/Abstract] OR ‘Co Cr’[Title/Abstract] OR CrCo[Title/Abstract] OR ‘Cr Co’[Title/Abstract] OR ‘Cr-Co’[Title/Abstract] OR ‘Co-Cr’[Title/Abstract] OR cobalt-chromium[Title/Abstract] OR chromium-cobalt[Title/Abstract] OR chrome-cobalt[Title/Abstract] OR cobalt-chrome [Title/Abstract]))

Search pubmed 2017-10-31 using mesh terms

((‘Dental Prosthesis’[Mesh]) AND ‘Chromium Alloys’[Mesh]) AND (gap OR gaps OR fit OR misfit OR precision OR accuracy)

Search scopus and web of science 2017-20-31

Search 1

cobalt chromium OR cobalt chrome OR CoCr OR ‘Co Cr’ OR CrCo OR ‘Cr Co’

OR ‘Cr-Co’ OR ‘Co-Cr’ OR cobalt-chromium OR chromium-cobalt OR chrome-cobalt OR cobalt-chrome

TITLE-ABS-KEY (prosthesis OR prostheses AND (dental OR dentistry)) OR TITLE-ABS-KEY (crown OR crowns OR bridge OR bridges OR fdp OR fixed AND partial AND denture OR fpd) AND TITLE-ABS-KEY (cobalt AND chromium OR cobalt AND chrome OR cocr OR ‘Co Cr’ OR crco OR ‘Cr Co’ OR ‘Cr-Co’ OR ‘Co-Cr’ OR cobalt-chromium OR chromium-cobalt OR chrome-cobalt OR cobalt-chrome)) AND (LIMIT-TO (LANGUAGE, ‘English’))

Search 2

FDP OR fixed partial denture OR FPD OR prosthesis OR prostheses AND (Dental OR dentistry) OR crown OR crowns OR bridge OR bridges

TITLE-ABS-KEY (prosthesis OR prostheses AND (dental OR dentistry)) OR TITLE-ABS-KEY (crown OR crowns OR bridge OR bridges OR fdp OR fixed AND partial AND denture OR fpd) AND TITLE-ABS-KEY (cobalt AND chromium OR cobalt AND chrome OR cocr OR ‘Co Cr’ OR crco OR ‘Cr Co’ OR ‘Cr-Co’ OR ‘Co-Cr’ OR cobalt-chromium OR chromium-cobalt OR chrome-cobalt OR cobalt-chrome)) AND (LIMIT-TO (LANGUAGE, ‘English’))

Inclusion and exclusion criteria

The inclusion criteria comprised studies of tooth-supported prostheses in CoCr with the following information described; fit assessment, measurement techniques, manufacturing technique (lost-wax, hard and soft CNC-milling, additive manufacturing), and pre-set cement spacer. Studies not meeting all inclusion criteria, studies of implant-supported prostheses and studies measuring fit after ceramic veneering were excluded.

Study selection

The authors independently screened the titles and abstracts from the studies found in the electronic searches described above, considering the inclusion criteria. Any disagreements were resolved after discussion. After selection, the full texts of the studies were acquired. These publications were again independently screened, and a final discussion took place to reach a consensus.

Extraction of data

Data from the included studies were independently extracted and registered in data extraction forms by the authors. The extracted data was checked and disagreements between the authors were discussed until a consensus was reached. In this review, the marginal gap (MG) was defined as the shortest distance from the preparation line to the inside of the restoration or from the most cervical edge of the restoration to the tooth [Citation20]. The internal gap (IntG) was the mean of all the internal measuring points (cervical, chamfer, axial, occlusal) and the total gap (TotG) was the mean of all the measuring points available in the studies (marginal, cervical, chamfer, axial, occlusal).

From the included studies, the following data was extracted (when available): Year of publication, Preparation type, Master model material, Impression technique, Restoration (crown or multi-unit FDP), Number of test specimens or patients, Pre-set spacer, CAD software, CAM, Manufacturing technique (Formative, Subtractive, Additive), Alloy, Fit analysis technique, Measuring points, Analysis area (absolute marginal gap, marginal gap, cervical area gap, axial gap, occlusal gap, internal gap, total gap).

Analyses

In the present review, mean values were calculated as weighted values based on the individual group mean value and number of test specimens or patients per group. Fit was the mean of distances reported in the studies and accuracy was the fit minus the pre-set spacer. The analyses were done for single crown and multi-unit FDPs, separately and combined. The SPSS (IBM SPSS v.24.0) statistics software was used for statistical analysis.

Results

Studies

The first searches done in PubMed, Scopus and Web of Science, resulted in 978 articles. In addition, a new PubMed search was done using mesh terms. After removal of duplicates, another 93 articles were added. The authors screened the titles and abstracts from the 1071 studies found independently, considering the inclusion criteria. After discussion, disagreements were resolved resulting in 57 articles which were analyzed in full-text by the authors independently of each other. A final discussion took place with the aim to reach a consensus, and another four articles were excluded, one due to wrong material (NiCr) [Citation21] and three since they were only conference reports [Citation22–24]. Hence, 53 articles were left for the final full-text analysis. With the inclusion and exclusion criteria applied, 35 articles were excluded. As a result, 18 articles met the inclusion criteria (See and ).

Figure 1. Search strategy.

Figure 1. Search strategy.

Table 1. The included studies and the results they present regarding impression technique, tooth area, manufacturing technique, pre-set cement spacer, number of test specimens and reported gaps (in micrometer).

Description of included studies and analyses

All results included in this review were of CoCr restorations before ceramic veneering. One study was clinical and involved patients and one used human teeth as master models. Twelve of the studies included single crowns and six measured the fit of multi-unit FDPs. Since most of the studies presented results from more than one test group the review resulted in 36 test groups with single crowns, four test groups with 4-unit FDPs and ten test groups with 3-unit FDPs. Most of the groups were comprised of ten specimens or patients but ranged from three to 110. Thirteen studies presented results from conventional impression techniques only and five studies compared conventional and digital impression techniques. The abutment teeth used in the studies were incisors, canines, premolars, and molars. The manufacturing techniques used were; eight test groups by CAD design with subtractive or additively produced wax patterns for the lost wax technique (CLW), nine test groups by the lost wax technique (LW), three test groups by soft milling (SMill), 16 test groups by hard milling (HM), and 14 test groups by additive manufacturing (AM). Several different CAD/CAM systems and alloys were used in the studies ().

Table 2. The different machines, CAD/CAM-systems and alloys presented in the included studies.

The included studies reported results from fit measurements, the results are presented as means for single crowns, multi-unit FDPs and combined (single crowns and multi-unit FDPs). Also, the results are given as fit (the distance between model/tooth and restoration) and accuracy (fit minus the pre-set spacer). The fit and accuracy results for total gap irrespective of manufacturing technique were 96 μm and 54 μm for single crowns, 107 μm and 54 μm for multi-unit FDPs, and 98 μm and 54 μm for both single crowns and multi-unit FDPs combined (). For manufacturing technique and the measuring area MG, AM single crown restorations presented the highest accuracy and CLW the lowest accuracy. For multi-unit FDPs in MG, HM presented the highest accuracy and CLW the lowest. The combination of single crowns and multi-unit FDPs showed AM as the technique with the highest accuracy and CLW as the one with the lowest accuracy (). For internal gap the manufacturing technique with the highest accuracy for single crowns was HM followed by SMill. AM had the lowest accuracy. Internal gap for multi-unit FDPs showed that HM had the highest accuracy and AM the lowest. CLW and SMill did not present any results for multi-unit FDPs (). For total gap and accuracy of single crowns SMill had the highest accuracy, for multi-unit FDPs AM had the highest (). With the results grouped by impression technique, the accuracy for total gap was highest for digital impressions and lower for conventional impressions ().

Figure 2. Fit and accuracy (μm) of single crowns (SC), multi-unit fixed dental prostheses (FDP) and combined divided by marginal gap, internal gap and total gap.

Figure 2. Fit and accuracy (μm) of single crowns (SC), multi-unit fixed dental prostheses (FDP) and combined divided by marginal gap, internal gap and total gap.

Figure 3. Marginal gap fit and accuracy (μm) of single crowns (SC), multi-unit fixed dental prostheses (FDP) and combined divided by production technique. SM: Soft milling, AM: Additive manufacturing, HM: Hard milling, LW: Lost wax, CLW: CAD lost wax.

Figure 3. Marginal gap fit and accuracy (μm) of single crowns (SC), multi-unit fixed dental prostheses (FDP) and combined divided by production technique. SM: Soft milling, AM: Additive manufacturing, HM: Hard milling, LW: Lost wax, CLW: CAD lost wax.

Figure 4. Internal gap fit and accuracy (μm) of single crowns (SC), multi-unit fixed dental prostheses (FDP) and combined divided by production technique. SM: Soft milling, AM: Additive manufacturing, HM: Hard milling, LW: Lost wax, CLW: CAD lost wax.

Figure 4. Internal gap fit and accuracy (μm) of single crowns (SC), multi-unit fixed dental prostheses (FDP) and combined divided by production technique. SM: Soft milling, AM: Additive manufacturing, HM: Hard milling, LW: Lost wax, CLW: CAD lost wax.

Figure 5. Total gap fit and accuracy (μm) of single crowns (SC), multi-unit fixed dental prostheses (FDP) and combined divided by production technique. SM: Soft milling, AM: Additive manufacturing, HM: Hard milling, LW: Lost wax, CLW: CAD lost wax.

Figure 5. Total gap fit and accuracy (μm) of single crowns (SC), multi-unit fixed dental prostheses (FDP) and combined divided by production technique. SM: Soft milling, AM: Additive manufacturing, HM: Hard milling, LW: Lost wax, CLW: CAD lost wax.

Figure 6. Fit and accuracy (μm) of conventional and digital impressions divided by marginal gap, internal gap and total gap.

Figure 6. Fit and accuracy (μm) of conventional and digital impressions divided by marginal gap, internal gap and total gap.

Discussion

The aim of this systematic review was to compare the fit and assess the accuracy of tooth-supported single and multi-unit FDPs in CoCr manufactured by different techniques. Thus, the ambition of the authors was to compare the mean fit and mean accuracy values from the different manufacturing techniques. Although the number of included studies (n = 18) was relatively high, considering the strict inclusion and exclusion criteria, the diversity among the studies makes it hard to draw many reliable conclusions. The presented manufacturing techniques included four casting machines, 12 CAD systems and 14 CAM systems. There were both clinical and laboratory studies. In all the 18 included studies, conventional impression techniques were used, and in five of them digital impression techniques were also applied. In addition, the included studies examined both single crowns (n = 12) and multi-unit FDPs (n = 6), 19 different CoCr-alloys were used, and the fit measurements were performed with three different techniques. These variations lead to a shortage of sufficient data for each single variable of interest for further analyses. Therefore, the results from the present systematic review are mainly descriptive, and the results should be regarded as indicating trends.

After full-text analysis, 35 studies were excluded. Among these, 14 were excluded due to no mention of pre-set cement spacer. Measurements that take place without a clearly defined cement spacer only reflect the total deviation from the master model and not the actual accuracy. As a consequence, regardless of whether or not these non-mentions have been done intentionally, the results regarding fit from the 14 studies are most difficult to interpret and far from the clinical reality.

The comparison of studies on fit is a complex undertaking, not least since so many different parameters can affect the fit of a tooth-supported FDP. The present review focused on manufacturing technique, type of impression and measuring technique. As a consequence, a limitation of the present review is that other parameters, that also potentially could have affected the results presented in the included studies, have not been analyzed. Among these are cementation pressure, preparation type, type of master model, and model material. Also, the included studies do not mention internal adjustments before fit analyses, which could have affected the results. Restorations produced using the lost-wax technique have most likely been adjusted since the process of casting will create an oxide layer and there is always a risk of casting fins, rough surfaces, and gas porosities [Citation25]. In a review by Nawafleh et al., the reliability of methods to measure marginal adaptation of crowns and FDPs was evaluated [Citation26]. They concluded that the differences in testing methods and parameters between the studies result in a lack of consensus regarding marginal adaptation.

The commonly used manufacturing techniques (lost-wax, hard milling and additive manufacturing) showed no major differences in fit values for marginal gap: 84 µm, 76 µm, and 69 µm, respectively. The accuracy for the same techniques was 37 µm, 75 µm, and 28 µm respectively. The results from the present systematic review revealed that no single manufacturing technique was superior to the others regarding accuracy for both single crowns and multi-unit FDPs, nor for all different measuring areas (MG, IntG and TotG). The diversity in parameters makes it problematic to draw any conclusions regarding manufacturing technique. Interestingly, all techniques, except CLW multi-unit FDPs, presented a fit within 100 µm for MG and would, therefore, be considered clinically acceptable according to earlier publications (1, 5-8). For internal and total gap however, 120 µm have been considered clinically acceptable (1, 7), and therefore AM, LW and CLW could be regarded as clinically unacceptable in those areas. The accuracy of 3 D printed dental casting patterns has been shown to deviate from the designed dimensions, which could explain the CLW results [Citation27]. Further, for the subtractive technique, different milling procedures have been shown to affect the accuracy [Citation28]. In the present review, only marginal gap measurements are presented to represent the fit at the margin. According to Holmes et al., the absolute marginal gap (AMG) is a more relevant measurement since it captures any horizontal or vertical discrepancies [Citation20]. It was the author’s ambition to use AMG. However, only three of the studies presented AMG measurements. The effect of the manufacturing technique on the fit of CoCr restorations has been evaluated regarding implant-supported restorations. For screw-retained full-arch FDPs, the manufacturing technique (HM and AM) did not significantly affect the fit [Citation29]. For cement-retained FDPs of different span lengths, LW had the lowest marginal discrepancy for 5-unit FDPs, and AM had the smallest marginal discrepancy for 3 and 4-unit FDPs [Citation30]. An earlier systematic review on the effect of manufacturing technique on marginal adaptation came to similar results; no clear conclusion could be drawn regarding the superiority of a specific technique [Citation31].

When the studies were divided into conventional and digital impressions, the results indicate that the digital impression technique had a higher accuracy, especially in internal and total gap. This corroborates the results by Haddadi et al., who compared the accuracy of crowns based on digital oral scanning and conventional impressions using a split-mouth randomized study design [Citation32]. In their study, crowns from digital impressions showed significantly better marginal and internal adaptation before cementation compared to conventional impressions. For full arch FDPs and longer span multi-unit FDPs, studies comparing digital and conventional impressions show no significant differences but suggest a more careful approach to using digital impression techniques [Citation33–35].

Based on these descriptive results, the fit of FDPs should be evaluated using a detailed protocol disclosing all parameters that could affect the results. In a comparative study, all FDPs should be manufactured using the same settings and with the same post-processing strategies, if possible. For evaluation of the fit at the margin, the absolute marginal gap should be the measuring area used.

Conclusions

Due to the inherent limitations of this systematic review, it still remains unclear what effect the manufacturing technique has on the fit of FDPs. However, the descriptive results suggest that the marginal fit of cobalt chromium FDPs is not negatively affected by the manufacturing technique.

Acknowledgements

The authors would like to acknowledge Torgny Alstad for statistical support and librarians Helen Sjöblom and Carina Torildsson at the Biomedicine Library, University of Gothenburg for great assistance with the literature search.

Disclosure statement

The authors report no conflict of interest.

References

  • McLean JW. Polycarboxylate cements. Five years' experience in general practice. Br Dent J. 1972;132(1):9–15.
  • Kane LM, Chronaios D, Sierraalta M, et al. Marginal and internal adaptation of milled cobalt-chromium copings. J Prosthet Dent. 2015;114(5):680–685.
  • Ishikiriama A, de Freitas Oliveira J, Vieira DF, et al. Influence of some factors on the fit of cemented crowns. J Prosthet Dent. 1981;45(4):400–404.
  • Jørgensen KD. Factors affecting the film thickness of zinc phosphate cements. Acta Odontol Scand. 1960;18(4):479–490.
  • Fonseca JC, Henriques GE, Sobrinho LC, et al. Stress-relieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings. Dent Mater. 2003;19(7):686–691.
  • Han HS, Yang HS, Lim HP, et al. Marginal accuracy and internal fit of machine-milled and cast titanium crowns. J Prosthet Dent. 2011;106(3):191–197.
  • McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131(3):107–111.
  • Fransson B, Oilo G, Gjeitanger R. The fit of metal-ceramic crowns, a clinical study. Dent Mater. 1985;1(5):197–199.
  • Colpani JT, Borba M, Della Bona A. Evaluation of marginal and internal fit of ceramic crown copings. Dent Mater. 2013;29(2):174–180.
  • Beuer F, Aggstaller H, Richter J, et al. Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int. 2009;40(3):243–250.
  • Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent. 1990;64(1):18–24.
  • Groten M, Axmann D, Probster L, et al. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent. 2000;83(1):40–49.
  • Sundar MK, Chikmagalur SB, Pasha F. Marginal fit and microleakage of cast and metal laser sintered copings–an in vitro study. J Prosthodont Res. 2014;58(4):252–258.
  • Falk A, von Steyern P, Fransson H, et al. Reliability of the impression replica technique. Int J Prosthodont. 2015;28(2):179–180.
  • Nakamura K, Mouhat M, Nergård JM, et al. Effect of cements on fracture resistance of monolithic zirconia crowns. Acta Biomater Odontol Scand. 2016;2(1):12–19.
  • Holst S, Karl M, Wichmann M, et al. A new triple-scan protocol for 3D fit assessment of dental restorations. Quintessence Int. 2011;42(8):651–657.
  • Ender A, Mehl A. Full arch scans: conventional versus digital impressions–an in-vitro study. Int J Comput Dent. 2011;14(1):11–21.
  • Atkins T, Escudier M. Precision. A dictionary of mechanical engineering. 2013 Online, Oxford University Press.
  • Moher D, The PRISMA Group, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097.
  • Holmes JR, Bayne SC, Holland GA, et al. Considerations in measurement of marginal fit. J Prosthet Dent. 1989;62(4):405–408.
  • Bajoghli F, Nosouhian S, Badrian H, et al. Effect of base metal alloys recasting on marginal integrity of castable crowns. J Contemp Dent Pract. 2013;14(2):255–258.
  • Uriciuc WA. Research about Precision Casting of Removable-Fixed Ensemble Applied in Dental Prosthodontics. IFMBE Proceedings. 2009: 26:379–382.
  • Rammelsberg P, Pospiech P, Gernet W. Clinical performance of adhesive fixed partial dentures with CoCr- and titanium-framework. J Dent Res. 1998;77:924.
  • Hansson O. Casting accuracy of a nickel and beryllium-free cobalt-chromium alloy for crown and bridge prostheses and etched-metal bridges. Swed Dent J. 1984;8(6):297.
  • Shen C. Dental casting alloys and metal joining. In: Anusavice KJS, Rawls HR, editor. Phillips´ science of dental materials. 12. St. Louis: Saunders; 2013. p. 387.
  • Nawafleh NA, Mack F, Evans J, et al. Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review. J Prosthodont. 2013;22(5):419–428.
  • Ishida Y, Miyasaka T. Dimensional accuracy of dental casting patterns created by 3D printers. Dent Mater J. 2016;35(2):250–256.
  • Kirsch C, Ender A, Attin T, et al. Trueness of four different milling procedures used in dental CAD/CAM systems. Clin Oral Invest. 2017;21(2):551–558.
  • Svanborg P, Eliasson A, Stenport V. Additively manufactured titanium and cobalt-chromium implant frameworks: fit and effect of ceramic veneering. Int J Oral Maxillofac Implants. 2018;33(3):590–596.
  • Akcin ET, Guncu MB, Aktas G, et al. Effect of manufacturing techniques on the marginal and internal fit of cobalt-chromium implant-supported multiunit frameworks. J Prosthet Dent. 2018;120(5):715–720.
  • Papadiochou S, Pissiotis AL. Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques. J Prosthet Dent. 2018;119(4):545–551.
  • Haddadi Y, Bahrami G, Isidor F. Accuracy of crowns based on digital intraoral scanning compared to conventional impression-a split-mouth randomised clinical study. Clin Oral Invest. 2019;23(11):4043–4050.
  • Malik J, Rodriguez J, Weisbloom M, et al. Comparison of accuracy between a conventional and two digital intraoral impression techniques. Int J Prosthodont. 2018;31(2):107–113.
  • Nedelcu RG, Persson AS. Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis. J Prosthet Dent. 2014;112(6):1461–1471.
  • Nedelcu R, Olsson P, Nystrom I, et al. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: a novel in vivo analysis method. J Dent. 2018;69:110–118.
  • Ates SM, Duymus ZY. Inluence of tooth preparation design on filling accuracy o CAD-CAM based restorations. J Esthet Restor Dent. 2016;28(4):238–246.
  • Dahl BE, Ronold HJ, Dahl JE. Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol. J Prosthet Dent. 2017;117(3):400–404.
  • Gunsoy S, Ulusoy M. Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing. Niger J Clin Pract. 2016;19(5):636–644.
  • Harish V, Mohammed Ali SA, Jagasedan N, et al. Evaluation of internal and marginal fit of two metal ceramic system - in vitro study. J Clin Diagn Res. 2014;8(12):Zc53–6.
  • Huang Z, Zhang L, Zhu J, et al. Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology. J Prosthet Dent. 2015;113(6):623–627.
  • Kim DY, Kim CM, Kim JH, et al. Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography. J Adv Prosthodont. 2017;9(3):176–181.
  • Kim KB, Kim WC, Kim HY, et al. An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system. Dent Mater. 2013;29(7):e91–6.
  • Kocaagaoglu H, Kilinc HI, Albayrak H, et al. In vitro evaluation of marginal, axial, and occlusal discrepancies in metal ceramic restorations produced with new technologies. J Prosthet Dent. 2016;116(3):368–374.
  • Lovgren N, Roxner R, Klemendz S, et al. Effect of production method on surface roughness, marginal and internal fit, and retention of cobalt-chromium single crowns. J Prosthet Dent. 2016;118(1):95–101.
  • Park JK, Kim HY, Kim WC, et al. Evaluation of the fit of metal ceramic restorations fabricated with a pre-sintered soft alloy. J Prosthet Dent. 2016;116(6):909–915.
  • Park JK, Lee WS, Kim HY, et al. Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems. J Adv Prosthodont. 2015;7(2):122–128.
  • Keul C, Stawarczyk B, Erdelt KJ, et al. Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization–a laboratory study. Dent Mater. 2014;30(4):400–407.
  • Kim KB, Kim JH, Kim WC, et al. Three-dimensional evaluation of gaps associated with fixed dental prostheses fabricated with new technologies. J Prosthet Dent. 2014;112(6):1432–1436.
  • Nesse H, Ulstein DM, Vaage MM, et al. Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques. J Prosthet Dent. 2015;114(5):686–692.
  • Svanborg P, Skjerven H, Carlsson P, et al. Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions. Int J Dent. 2014;2014:1–9.
  • Ueda K, Beuer F, Stimmelmayr M, et al. Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions. Clin Oral Invest. 2016;20(2):283–289.
  • Örtorp A, Jonsson D, Mouhsen A, et al. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. Dental Materials. 2011;27(4):356–363.