Evaluation of an FIA Operated Amperometric Bacterial Biosensor, Based on Pseudomonas Putida F1 for the Detection of Benzene, Toluene, Ethylbenzene, and Xylenes (BTEX)

, , , , &
Pages 1531-1547 | Received 23 Mar 2005, Accepted 01 Apr 2005, Published online: 02 Feb 2007
 

Abstract

Recently, the development and optimization of a flow injection analysis (FIA) operated bacterial biosensor based on the aerobic catabolism of Pseudomonas putida ML2 was reported in the literature (Lanyon et al. 2004, 2005). By adapting information from these reports, we investigated whether operating parameters and procedures of the benzene biosensor could be directly applied to a new system based on a different bacterial strain for the detection of the whole benzene, toluene, ethylbenzene, and xylenes range. Cells of the investigated bacterial strain, Pseudomonas putida F1, were immobilized between two cellulose acetate membranes and fixed onto a Clark dissolved oxygen electrode. The P. putida F1 aerobically degrades benzene, toluene, and ethylbenzene (BTE) (Cho et al. 2000). The BTE biosensor in kinetic mode FIA displayed a linear range of 0.02–0.14 mM benzene (response time: 5 min, base-line recovery time: 15 min), 0.05–0.2 mM toluene (response time: 8 min, baseline recovery time: 20 min), and 0.1–0.2 mM ethylbenzene (response time: 12 min, baseline recovery time: 30 min), respectively. Due to the differences in sensitivity, response, and baseline recovery times for BTE, it was possible to differentiate each compound in mixtures of these volatile organic compounds (VOCs). No response for xylenes could be obtained since they cannot be completely metabolized by this bacterial strain. However, it was reported that the range of compounds degradable by P. putida F1 can possibly be expanded by cultivating the cells on different carbon sources (Choi et al. 2003). The sensor showed good intra‐ and interassay reproducibility, and all obtained results were comparable with those reported in the literature. The demonstrated reproducibility and the simplicity and ease of use as well as the portability for in situ measurements indicates that the biosensor could be suitable as a reliable initial warning device for elevated BTE levels in indoor and outdoor environments.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 61.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 768.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.