The effect of transient glare on shape discrimination threshold in myopic adults

, MD, , PhD, , MD, , MD, , MD, , , MD, , MD, , MD & , OD show all
Pages 220-224 | Received 23 Jan 2017, Accepted 16 Jun 2017, Published online: 21 Apr 2021
 

Abstract

Background

The aim was to evaluate the effect of transient glare on shape discrimination threshold (SDT) in myopic adults.

Methods

A total of 162 myopic subjects were enrolled. Of these, 121 had low to mid myopia (−1.00 D to −6.00 D) and 41 had high myopia (−6.13 D to −10.25 D). All subjects had corrected visual acuity of 6/6 or better, and only data for the right eye were included in the study. SDTs were measured with circular D4 (fourth derivative of Gaussian) radial frequency patterns with a radial frequency of four, peak spatial frequency of three cpds, and mean radius of 1.5 degrees. SDTs were measured under two conditions, with and without the presence of transient glare while the stimulus was displayed (duration = 500 ms).

Results

Without transient glare, SDTs were not different between the low‐mid (23.84 ± 6.02 arcsec) and high myopia groups (25.17 ± 5.98 arcsec, p = 0.16, Mann–Whitney test). With transient glare, SDTs in all subjects became significantly higher (p < 0.001, Wilcoxon signed‐rank test). SDTs in the high myopia group (55.53 ± 18.59 arcsec) became significantly higher than those in the low to mid myopia group (47.55 ± 15.06 arcsec, p = 0.014, Mann–Whitney test). The increments were significantly higher in the high myopia group (28.94 arcsec versus 20.88 arcsec, p = 0.031, Mann–Whitney test). Multiple regression showed that SDTs with glare were significantly associated with SDTs without glare (p < 0.001) and the presence of high myopia (p = 0.015).

Conclusions

Transient glare significantly increased SDTs in all myopic subjects, with the increment in subjects with high myopia being significantly larger than those in subjects with low to mid myopia.

ACKNOWLEDGEMENTS

This research was supported by the Foundation of Wenzhou Science & Technology Bureau (Y20150272); and Innovative Project of School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University (YNKT201504).

Additional information

Funding

Foundation of Wenzhou Science & Technology Bureau
Innovative Project of School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Purchase Issue

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 84.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.