The role of macular pigment assessment in clinical practice: a review

, BSc (Hons) MCOptom PhD FAAO, , BSc (Hons) MCOptom & , BSC (Hons) MCOptom PhD FAAO MBA
Pages 300-308 | Received 11 Feb 2010, Accepted 26 Mar 2010, Published online: 15 Apr 2021
 

Abstract

This review compares the results of studies that have investigated the impact of lutein and zeaxanthin supplementation on macular pigment optical density (MPOD) with those that have investigated the reliability of techniques used to measure macular pigment optical density. The review will focus on studies that have used heterochromatic flicker photometry for measurement of macular pigment optical density, as this is the only technique that is currently available commercially to clinicians. We identified articles that reported on supplementation with lutein and/or zeaxanthin and/or meso‐zeaxanthin on macular pigment optical density measurement techniques published in peer‐reviewed journals, through a multi‐staged, systematic approach. Twenty‐four studies have investigated the repeatability of MPOD measurements using heterochromatic flicker photometry. Of these, 10 studies provided a coefficient of repeatability or data from which the coefficient could be calculated, with a range in values of 0.06 to 0.58. The lowest coefficient of repeatability assessed on naïve subjects alone was 0.08. These values tell us that, at best, changes greater than 0.08 can be considered clinically significant and at worst, only changes greater than 0.58 can be considered clinically significant. Six studies assessed the effect of supplementation with up to 20-mg/day lutein on macular pigment optical density measured using heterochromatic flicker photometry and the mean increase in macular pigment optical density ranged from 0.025 to 0.09. It seems reasonable to conclude that the chance of eliciting an increase in macular pigment optical density during six months of daily supplementation with between 10 and 20-mg lutein that is of sufficient magnitude to be detected by using heterochromatic flicker photometry on an individual basis is small. Commercially available heterochromatic flicker photometers for macular pigment optical density assessment in the clinical environment appear to demonstrate particularly poor coefficient of repeatability values. Clinicians should exercise caution when considering the purchase of these instruments for potential monitoring of macular pigment optical density in response to supplementation in individual patients.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Purchase Issue

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 84.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.