Intra‐observer repeatability of optical quality measures provided by a double‐pass system

, MSc, , PhD & , MD PhD
Pages 60-65 | Received 20 Jan 2011, Accepted 24 Jun 2011, Published online: 15 Apr 2021
 

Abstract

Purpose:  The aim was to evaluate the intra‐observer repeatability of the ocular optical quality measurements provided by a double‐pass system in healthy eyes.

Methods:  A total of 24 healthy eyes of 24 patients with ages ranging from 20 to 60-years were included in the study. Three consecutive measurements were obtained by an experienced examiner with the Optical Quality Assessment System (Visiometrics) of the following parameters defined by the manufacturer as follows: cut‐off spatial frequency for the modulation transfer function (COMTF), Strehl ratio, width of the point spread function (PSF) at 10 per cent of its maximal height (PSF10) and width of the PSF at 50 per cent of its maximal height (PSF50). Intra‐observer repeatability for 3.0-mm pupil measurements was evaluated by the within‐subject standard deviation (Sw) and intra‐class correlation coefficient (ICC).

Results:  The Sw values for the different parameters evaluated were 4.34 cycles per degree for COMTF, 0.03 for the Strehl ratio, 1.14 arcmin for PSF10 and 0.36 arcmin for PSF50. The ICC values for these parameters were 0.746, 0.627, 0.783 and 0.814 for COMTF, Strehl ratio, PSF10 and PSF50, respectively. Statistically significant correlations were found between COMTF and the Sw for PSF50 (r = ‐0.45, p = 0.03), and between the Sw and the mean value for PSF50 (r = 0.42, p = 0.04). The significance of these correlations would vanish when considering the Bonferroni correction.

Conclusions:  Measurements provided by the Optical Quality Assessment System should be considered and interpreted with caution because their consistency seems to be limited, especially in eyes with poor optical quality. The limitation in the validity of measurements due to the use of infrared light instead of middle‐wavelength light should also be considered.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Purchase Issue

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 84.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.