Towards quantifying cochlear implant localization performance in complex acoustic environments

&
Pages S27-S29 | Published online: 18 Jul 2013
 

Abstract

Cochlear implant (CI) users frequently report listening difficulties in reverberant and noisy spaces. While it is common to assess speech understanding with implants in background noise, binaural hearing performance has rarely been quantified in the presence of other sources, although the binaural system is a major contributor to the robustness of speech understanding in noisy situations with normal hearing. Here, a pointing task was used to measure horizontal localization ability of a bilateral CI user in quiet and in a continuous diffuse noise interferer at a signal-to-noise ratio of 0 dB. Results were compared to localization performance of six normal hearing listeners. The average localization error of the normal hearing listeners was within normal ranges reported previously and only increased by 1.8° when the interfering noise was introduced. In contrast, the bilateral CI user showed a localization error of 22° in quiet which rose to 31° in noise. This increase was partly due to target sounds being inaudible when presented from frontal locations between −20° and +20°. With the noise present, the implant user was only able to reliably hear target sounds presented from locations well off the median plane. The results give support to the informal complaints raised by CI users and can help to define targets for the design of, e.g., noise reduction algorithms for implant processors.

Acknowledgements

This study was sponsored by the Intramural Programme of the MRC and Cochlear Europe Ltd. We are thankful for the support received from Paula Greenham and Brendan Murray. We are very grateful to our participants for their time and to the following centres for their help with recruitment: The South of England Cochlear Implant Centre, the Birmingham Adult Cochlear Implant Programme, the University Department of Otolaryngology – Head and Neck Surgery at Manchester Royal Infirmary and the Hearing Services Ropewalk House, Nottingham.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 380.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.