Publication Cover
Neurological Research
A Journal of Progress in Neurosurgery, Neurology and Neurosciences
Volume 35, 2013 - Issue 9
424
Views
23
CrossRef citations to date
0
Altmetric
Original Article

The diagnostic accuracy of TCD for intracranial arterial stenosis/occlusion in patients with acute ischemic stroke: the importance of time interval between detection of TCD and CTA

, , , &
Pages 930-936 | Received 14 Dec 2013, Accepted 12 May 2013, Published online: 18 Nov 2013
 

Abstract

Objective: To evaluate prospectively the diagnostic accuracy of transcranial doppler (TCD) as an additional screening tool for intracranial arterial steno-occlusive disease against computed tomography angiography (CTA) in patients with acute ischemic stroke (AIS) if both are performed in a short time interval.

Methods: Between July 2011 and May 2012, 128 patients who were hospitalized within 24 hours of symptom onset and fulfilled the criteria for the clinical diagnosis of AIS were enrolled. Bedside detection of TCD was accomplished immediately after admission. High-resolution brain CTA was performed within 3 hours after the completion of TCD and the images were interpreted by a neuroradiologist blinded to TCD findings. The accuracy parameters of TCD against CTA were calculated after computation of true-positive, false-positive, true negative, and false-negative values.

Results: Among the 128 patients, there were 68 males and 60 females, aged 61·4±17·5 years. The mean time interval between the detection of TCD and CTA was 89·7 (77·8) minutes. In 65% of patients, both examinations were performed with less than a half-hour interval between them. The diagnostic accuracy of TCD for different arteries showed slight distinction. Transcranial doppler demonstrated the most accurate diagnosis for middle cerebral artery (MCA), where TCD showed 35 true-positive, 0 false-negative, 1 false-positive, and 92 true-negative studies compared with CTA. Furthermore, elevated MCA velocities on TCD correlated well with the severity of intracranial stenosis detected on CTA. Vertebral artery (VA) is one of the arteries with the lowest sensitivity for TCD diagnosis (sensitivity 63·4%, specificity 96·5%, positive predictive value (PPV) 89·6%, negative predictive value (NPV) 84·8%, and accuracy 85·9%). In 20 cases (15·6%), TCD showed findings complementary to CTA (real-time embolization, collateral flow patterns, and steal phenomenon).

Conclusions: Transcranial doppler shows high diagnostic accuracy against CTA if both are performed in a short time interval in evaluating intracranial arterial stenosis/occlusion in patients with AIS, especially for MCA obstruction. Transcranial doppler can also provide additional real-time dynamic findings complementary to the information provided by CTA. This can result in changes in the management in some of these patients.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 421.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.