H2-HT Separation Using “Cryogenic-Wall” Thermal Diffusion Column with Heated-Tube

, , &
Pages 415-419 | Published online: 13 May 2017
 

Abstract

The pressure dependence of separation factors of the columns for H2-HT mixture was measured for practical design of “cryogenic-wall” thermal diffusion columns for tritium handling system. Experiments were performed with 1,020 mm-height column with a 4.8 mm-outer-radius tube heated by hot-water and a 11.5 mm-inner-radius tube cooled by liquid nitrogen. The maximum total separation factor was 12.7 at 80 kPa for H2-HT separation. By using another column with 9.53 mm-outer-radius tube heated by hot-water and a 14.2 mm-inner-radius tube, the separation factor was 64.4 at 144 kPa, and the separation will be larger at higher pressure.

Comparison of numerical calculations of axial and radial two-dimensional flow and concentration distribution with experimental data revealed that our code could predict the pressure dependence of separation factor of the columns well.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.