5
Views
15
CrossRef citations to date
0
Altmetric
Tritium Processing

Pressure Dependence of Separative Characteristics of Thermal Diffusion Column for H2-HT Isotope Separation

, &
Pages 590-595 | Published online: 10 Aug 2017
 

Abstract

Experiments of H2-HT isotope separation were carried out with a hot wire column of 3 cm in diameter and 1.5 m in length. Separation factors were measured with cut changed from 0.1 to 0.9, and other operational conditions; pressure, feed rate and temperature difference, fixed. First, the feed rate was altered under the constant pressure, and next, pressure was changed. Experimental results were compared with those from an axisymmetric separative analysis, based on a Newton iterative solution of a convection-diffusion equation. Pressure dependence of separation factors agreeed qualitatively with those from theory. The separative power has a maximum value at 0.12 ∼ 0.16 MPa, when the feed rate was under 100 cm3/m(at 0.1 MPa, 25°C).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?