115
Views
0
CrossRef citations to date
0
Altmetric
Original Research

Detection of human mammaglobin mRNA in breast cancer cells among Vietnamese women

&
Pages 143-150 | Published online: 18 Mar 2019

Abstract

Background

Detecting circulating tumor cells (CTCs) is a promising approach for evaluating the progression of occult metastases as well as the efficacy of treatment therapies among patients with breast cancer. A real-time reverse transcriptase polymerase chain reaction (RT-PCR) technique has been proposed for detecting CTCs due to its high sensitivity. In this study, we aimed to validate the RT-PCR technique for human mammaglobin (hMAM) mRNA detection among Vietnamese women with breast cancer.

Patients and methods

Peripheral blood samples and breast cancer tissues from 43 patients suffering from breast cancer and 21 patients with fibroids were obtained. Real-time RT-PCR and gene sequencing techniques were employed to detect hMAM gene in CTCs of breast cancer cell lines and cancer tissues.

Results

hMAM mRNA transcription was detected in 36 out of 43 (83.7%) breast cancer tissues and in blood of 23 out of 43 (53.5%) breast cancer patients, while it was detected in only 9.5% out of tissues and 0% of the blood of fibrosis patients. hMAM mRNA in the peripheral blood of breast cancer patients increased with tumor size, stage of cancer and distant metastasis (P<0.05). No difference in the expression of hMAM mRNA was found in breast cancer tissue regarding age, distant metastasis, lymph node, stages of cancer and histopathology (P>0.05).

Conclusion

The study highlighted the expression of hMAM mRNA in breast cancer cells and tissues. This reveals the overall picture of the replication of hMAM mRNA in breast cancer, suggesting the role of hMAM mRNA in breast cancer molecular pathology.

Introduction

Breast cancer is a common health issue among women in Vietnam. A recent report estimates that the age-standardized incidence rate of breast cancer in Vietnamese women increased significantly from 13.8 to 29.9 per 100,000 women between 2000 and 2010, which means that there would be 12,533 new breast cancer cases annually nationwide.Citation1 Early screening, detection and treatment are thus vital for the reduction of this disease burden.Citation2 Recently, detecting circulating tumor cells (CTCs) has been found to be a promising approach for evaluating the progression of occult metastases as well as the efficacy of treatment therapies among patients with breast cancer.Citation3 CTCs flow in the patients’ peripheral blood stream and are believed to be a mediator of distant metastases of breast cancer to other organs.Citation4Citation6 Thus, identifying CTCs in the peripheral blood of breast cancer patients can have critical implications in assisting oncologists to determine appropriate therapeutic methods.

A number of methods have been tested to detect CTCs, such as cytogenetics, morphology and flow cytometry, but they have shown limited diagnostic values.Citation7 Recently, a real-time reverse transcriptase polymerase chain reaction (RT-PCR) method has been proposed for the detection of CTCs due to its high sensitivity.Citation8Citation10 This technique uses specific expression of marker genes for different tissues or tumors in order to detect the existence of these tumor cells.Citation3 It has been previously used to identify circulating breast cancer cells among patients with metastates.Citation10,Citation11

Markers for RT-PCR may vary across clinical settings, of which human mammaglobin (hMAM) mRNA is one of the most specific markers for detecting CTCs via peripheral blood in breast cancer patients.Citation12,Citation13hMAM is a glycoprotein with 93 amino acids and a member of secretoglobin–uteroglobin family.Citation3,Citation14 Its expression and overexpression are primary in mammary tissues and breast cancer tissues, respectively.Citation3,Citation14 However, to date, there is a lack of data about the expression of hMAM mRNA in the Vietnamese population. Our hypothesis is that there is a significant difference in the expression of hMAM mRNA between breast cancer tissue and fibrosis tissue, as well as between breast cancer tissue and peripheral blood of breast cancer patients. In this study, we aimed to validate the RT-PCR technique for hMAM mRNA among Vietnamese women with breast cancer.

Patients and methods

Study design and sampling

A total of 43 patients with confirmed breast cancer in all stages were recruited at the time of diagnosis at the K Hospital – the largest oncology hospital in Vietnam. They were excluded if they had tumors in other organs, were treated by any therapies and did not accept to participate. In addition, 21 fibroid patients in the same hospital were also invited to participate in the study. A convenient sampling technique was used to recruit patients.

Blood samples

Five milliliters of peripheral blood in both breast cancer patients and fibroid patients was obtained and stored in EDTA. The blood samples were centrifuged at 4,000 rpm for 20 minutes. After that, the plasma was removed and the white blood cells were collected to enrich the cells, including breast cancer cells. Samples were stored at 4°C and processed immediately after being drawn.

Tissue samples

About 20–30 mg of tissue samples were obtained from those patients from whom blood was drawn, after they had a surgery to remove the tumor. Samples were then stored in sterile vials at −80°C until RNA separation.

Breast cancer cells

MCF-7, BT-474, KPL-4 and MDA-MB231 cells were cultured in DMEM with high glucose (Thermo Fisher Scientific, Waltham, MA, USA) +10% FBS (Thermo Fisher Scientific) +1% penicillin/streptomycin (Thermo Fisher Scientific) +2 mM l-glutamine. These cells were counted before the experiment. These cell lines were purchased from Vietnam Academy of Science and Technology. They were counted using the following steps:

  • We took 90 µL of cell culture fluid +10 µL of trypan blue which were incubated at room temperature for about 3–4 minutes. Then, we took 10 µL of cells after dyeing with trypan blue and placed them in a Neubauer counting chamber.

  • We counted the number of living cells in each 1 mm2.

Living cells were not stained and the total number of cells was calculated according to the following formula:

  1. Cell concentration in the initial fluid = total number of cells counted (in 1 mm2 cells)/count times ×104× dilution × (10/9) (cells/mL)

  2. Total cell count = cell concentration in the initial fluid × number of cell fluids (cells)

RT-PCR procedure

Tumor cells in the blood were obtained by centrifuging the blood samples at 4,000 rpm for 20 minutes. Cells in breast cancer tissues were taken after the tumor removal surgery. Samples were stored at 4°C and sent immediately to the laboratory for total RNA extraction. Total RNA from breast cancer cells in the peripheral blood and tissues was processed using the Mini Kit (Qiagen Kit Rneasy; Qiagen, Hilden, Germany). The purity and concentration of total RNA were checked by using RNA absorption spectrum on NanoDrope-1000. The purity depends on the ratio of OD at 260 nm to OD at 280 nm, and the ratio ranging from 1.7 to 2.0 is acceptable for considering purity.

cDNA creation (RT-PCR) was done using the Invitrogen™ SuperScript II Reverse Transcriptase with up to 1 pg of total RNA. Because the total RNA samples extracted from the tissues and the blood samples were not similar, it was necessary to adjust the process from total RNA to cDNA in order to ensure that the imports for real-time PCR had equivalent total RNA (about 100 ng). First, we used about 100 ng of total RNA and mixed it with RNase-free water to obtain a volume of 6 µL per tube. One microliter of the reaction mix and 1 µL or random hexamers were also added and incubated at 65°C for 5 minutes; then, this combination was kept on ice for 1 minute. Finally, 10 µL of buffer and 2 µL of enzyme were added to reach a volume of 20 µL per tube.

cDNA was synthesized in three thermal cycles: 25°C/10 minutes, 50°C/50 minutes, and 85°C/5 minutes. The cDNA product was stored at −20°C according to the manufacturer’s guideline (Thermo Fisher Scientific). RT-PCR was performed with the primers for hMAM, GAPDH. GAPDH is a standard gene. We implemented PCR reaction with GAPDH F/R primer to test the quality of synthesized cDNA. After confirming that good-quality cDNA was synthesized, PCR was conducted with hMAM primer. A standard curve was built by using breast cancer samples with a certain number of cells (2×104). We performed PCR for cDNA, which was synthesized from sample and breast cancer cells. hMAM primers () were used to check this process.

Table 1 Sequences of primers used in this study

PCR and sequencing

PCR from cDNA was processed with hMAM and GAPDH primers. PCR product was checked by electrophoresis on 1% agarosegel. Several samples were sequenced to confirm that the cloned genes were hMAM genes.

Real-time PCR

Real-time PCR with hMAM primer was conducted using Roche’s SYBR Green kit. Copies obtained from PCR products were computed as follows:

where 340 is the molecular weight of a nucleotide and 6.022×1023 is the number of molecules in 1 mole of the substrate.

Standard curves were built by calculating the number of cDNA in each tube after diluting at the rate 10/100/1.000/10.000. SYBR Green, the amplified response could be seen through the emitted fluorescence signal, which is attached to the double-stranded DNA from the start to the end of the process, by using a camera system that can track the fluorescence signal in each tube. The results were applied to construct the standard curves and then were used for calculating the cDNA copies.

Statistical analysis

Data were analyzed using SPSS 16.0 software (SPSS, Inc., Chicago, IL, USA). Chi-squared test was used to identify the differences in hMAM (+) expression in various groups. A P-value <0.05 was considered statistical significance.

Ethical consideration

The study protocol was approved by the Institutional Review Board of the Ministry of Health and Hanoi Medical University (3018/QD-BYT). Informed consent was obtained from all patients before the experiment. This study was conducted in accordance with the Declaration of Helsinki.

Results

After cloning the cDNA of hMAM by PCR from four breast cancer cell lines, KPL4, MCF7, BT474 cell lines were positive and the MDA-MB231 cell line was negative () for the presence of the gene.

Figure 1 Electrophoresis image of polymerase chain reaction cDNA of hMAM and GAPDH in breast cancer cells.

Abbreviation: hMAM, human mammaglobin mRNA.
Figure 1 Electrophoresis image of polymerase chain reaction cDNA of hMAM and GAPDH in breast cancer cells.

Standard curves were developed using 20,000 BT474 cell lines. Concentrations of PCR were obtained at ~679 ng. According to the formula, the number of cDNA copies of hMAM generated from the breast cancer cell line BT474 was 105. Based on this standard, it is possible to calculate the number of copies of hMAM mRNA ().

Figure 2 Real-time PCR for cDNA of hMAM to determine the standard curve using BT474 cell lines.

Abbreviation: hMAM, human mammaglobin mRNA; PCR, polymerase chain reaction.
Figure 2 Real-time PCR for cDNA of hMAM to determine the standard curve using BT474 cell lines.

shows the sequencing of the PCR products to confirm that the amplified gene sample was a copy of the hMAM gene, which was published in the gene bank.

Figure 3 Sequences of hMAM gene in PCR positive.

Abbreviation: hMAM, human mammaglobin mRNA; PCR, polymerase chain reaction.
Figure 3 Sequences of hMAM gene in PCR positive.

Standard curves were made by measuring crossing point (CP) values () in six reaction tubes. Tube hMAM cDNA 1× was generated from 20,000 BT474 cells, which was equivalent to 105 copies. At a dilution of 100 times, which equaled to 200 breast cancer cells, the copies were detected with the CP at 33.14 and the number of copies at 893. Less CP value had higher number of cDNA copies.

Figure 4 Real-time PCR for hMAM cDNA determined the detection level in BT474 cell lines.

Abbreviation: CP, crossing point; hMAM, human mammaglobin mRNA; PCR, polymerase chain reaction.
Figure 4 Real-time PCR for hMAM cDNA determined the detection level in BT474 cell lines.

shows that hMAM mRNA transcription was detected in 83.7% of the breast cancer tissues and in blood of 53.5% of breast cancer patients, while it was detected in only 9.5% of the fibrosis tissues and 0% in blood of fibrosis patients.

Table 2 hMAM mRNA transcription in the study

reveals that hMAM mRNA in the peripheral blood of breast cancer patients increased with tumor size, stage of cancer and distant metastasis (P<0.05). We did not find any differences in hMAM mRNA in the breast cancer tissue.

Table 3 hMAM expression in the breast cancer tissue and blood according to different characteristics

Discussion

In this study, RT-PCR technology allows to investigate low levels of mRNA that cannot be detected by other classical methods such as the northern blot.Citation15 RT-PCR is often considered the most sensitive test for detecting molecular markers of tumors.Citation16 RT-PCR also provides a high specificity with the design of specific genes of interest.

The synthesis of cDNA based on RNA was performed by reverse enzymes. After cDNA synthesis, cDNA quality was tested by the amplification of GAPDH (internal standard) gene with specific primers. GAPDH is present in every cell of the body and is often used to test the quality of cDNA, eliminating false-negative cases due to poor quality of cDNA. After the amplification reaction, if the quality of the cDNA is poor or cDNA is contaminated, the electrophoretic band on agarose will be blurred and other sub-bands will appear. Our results showed that the PCR product with GADPH F/R primers showed a dark light band with the size of about 307 bp, as expected. This demonstrates that RNA quality and cDNA syntheses were successful, and the cDNA produced met the conditions that were required for subsequent hMAM gene replication.

Initial trials were performed on four breast cancer cell lines, MCF-7, KPL-4, BT-474 and MDA-MB231. hMAM was expressed in three out of the four breast cancer cell lines, except MDA-MB231. It has been argued that none of the genes are expressed in all breast cancer cell lines, but the cancer cell line remains the fundamental for cancer research.Citation17,Citation18

hMAM is one of 23 members of the secretoglobin–uteroglobin family. With northern blot and RT-PCR techniques, hMAM was detected in 90% malignant breast cancer tissues, while it was not detected in benign breast tissue or healthy breast tissue or was detectable at very low levels.Citation19 Of 43 breast cancer samples, 36 cases (83.7%) showed hMAM mRNA replication. This result is in line with previous studies. According to Raica et al, using RT-PCR, the detection rate for hMAM in primary breast cancer was 78.7%.Citation20 According to Al Joudi, the detection rate of hMAM mRNA in breast cancer tissue was 90%.Citation19 With a very high detection rate in breast cancer, hMAM mRNA is the perfect marker for breast cancer diagnosis. Detection of hMAM in breast cancer tissue is an important positive finding for the expression of hMAM mRNA in CTCs. Meanwhile, in the non-cancer control group in the study (ie, fibrous tissue), after performing the RT-PCR technique, only two samples (9.5%) showed hMAM mRNA replication, which was much lower than that in the breast cancer patients.

The rate of expression of hMAM mRNA in the breast cancer tissue was very high. Among cases with very small tumor (ie, <2 cm – T1), 90% cases were found to have hMAM mRNA copies. hMAM mRNA copies were found in 87.5% cases among patients in Phase I (very early stage) and 76.7% of patients with the absence of lymph node metastases. This suggests that hMAM replication is present in the tumor tissue at the early stage and the hMAM mRNA in tissues may be used for early diagnosis of breast cancer. Results showed no statistically significant difference in the incidence of hMAM mRNA expression with tumor size, lymph node metastasis, distant metastasis and stage of disease. Roncella et al, study ing 148 breast cancer samples, showed that the incidence of hMAM mRNA in breast cancer patients was 63%, 56% and 100% among patients having tumor size of <2, 2–5 and >5 cm, respectively.Citation21 The authors did not find any differences in the presence of hMAM mRNA in age, histopathologic and lymph node status.Citation21 Al-Joudi et al found that the detection rate of hMAM mRNA in breast cancer was not related to tumor size, marital status, family history of breast cancer and the presence of PR, ER, HER endocrine receptors.Citation22 Thus, hMAM mRNA was detected at an early stage of breast cancer with high rates. This result implies the potential use of hMAM mRNA as a new marker contributing to the diagnosis of breast cancer.

On comparing the detection rate of hMAM mRNA in the peripheral blood of patients with breast cancer, we found that the expression of hMAM mRNA in the blood was related to the disease stage, tumor size and distant metastasis. Research shows that by detecting hMAM mRNA replication, breast cancer cells in the blood can be found in the early stage when the tumor is small, without clinical metastases. According to Lee et al, the rate of hMAM mRNA detection in peripheral blood in the first and second stages was 23.4% and in the third and fourth stages was 82.9%. The hMAM mRNA expression rate in the blood was related to lymph node metastasis, distant metastasis and endocrine receptors.Citation23 Nakagawa et al detected CTCs in 29% cases with stage I, 45% cases with stage II and 77% cases with stage III.Citation24 Grünewald et al demonstrated that hMAM mRNA level was associated with tumor size and lymph node metastases, while no association was found for other genes.Citation12

In this study, RT-PCR was conducted with breast cancer cell lines, breast cancer tissues, peripheral blood of breast cancer patients and breast tissues of patients with breast fibroids in order to detect the differences in hMAM mRNA in both groups of patients. On comparing to Gene Bank, we found that hMAM mRNA expression levels in both groups were similar. The similarity was 100% with hMAM gene published in the International GenBank with codes AY893203, AY888136 and U33147. We supposed that the expression of hMAM mRNA found in breast cancer patients is an over-replication of the mRNA, resulting in increased synthesis of mammaglobin protein, which might be the cause of tumor cell growth. In fact, using RT-PCR, Watson et al did not find hMAM expression in different benign tissues or in tumors that are only found in breast cancer.Citation25 Therefore, we assumed that the hMAM mRNA abnormalities in women with breast cancer were not inherited, even after they migrated to other societies. However, further studies are needed to understand clearly the mechanism of this gene in next generations in order to develop appropriate prevention strategies.

Standard curves were developed based on the breast cancer cell lines with enhanced gene copying. According to the RT-PCR results, BT474 cell lines detected hMAM mRNA replication, which can be used to construct the curve. After counting the number of specific cells per milliliter, we performed total RNA synthesis and generated cDNA using PCR with hMAM primer. The product mass measurement obtained from the PCR reaction was the amplified hMAM gene. Based on the formula to transform the product mass to the number of copies of the hMAM gene after amplification, we divided it by 2Citation12 (25 was the number of PCR cycles) to compute the number of copies of the hMAM cDNA extracted from 20,000 BT474 cells at the first stage. At the 100-fold dilution equivalent to 200 breast cancer cells and CP equal to 33, 14,893 copies were identified as the lowest threshold that could detect hMAM replication. According to Zehentner et al, by using RT-PCR technique to mix BT474 breast cancer cell lines with 5 mL of blood from healthy people, the detection threshold was 100 BT474 cells/mL of blood, and the detectable copy threshold was greater than 1,000.Citation26

The strengths of this study included the development of a procedure to detect hMAM mRNA from the breast cancer tissue and peripheral blood of breast cancer patients. The results show that hMAM could be detected in the blood at a very early stage. This could be the initial step to monitor treatment of breast cancer along with other markers, actively contributing to the diagnosis and treatment of breast cancer. Meanwhile, small sample size in this study could reduce the representativeness of the population to the entire population of women with breast cancer in Vietnam.

Conclusion

In summary, the results of the study provide an overall picture of the replication of hMAM mRNA in breast cancer, suggesting the role of hMAM mRNA in breast cancer molecular pathology.

Disclosure

The authors report no conflicts of interest in this work.

References

  • DieuBDucNBThuanTVCancer challenges and national cancer control programs to 2020Viet Nam J Oncol20124131318
  • JenkinsCMinhLNAnhTTBreast cancer services in Vietnam: a scoping reviewGlob Health Action2018111143534429473488
  • LiGZhangJJinKHuman mammaglobin: a superior marker for reverse-transcriptase PCR in detecting circulating tumor cells in breast cancer patientsBiomark Med20115224926021473729
  • CristofanilliMBuddGTEllisMJCirculating tumor cells, disease progression, and survival in metastatic breast cancerN Engl J Med2004351878179115317891
  • CristofanilliMHayesDFBuddGTCirculating tumor cells: a novel prognostic factor for newly diagnosed metastatic breast cancerJ Clin Oncol20052371420143015735118
  • XenidisNIgnatiadisMApostolakiSCytokeratin-19 mRNA-positive circulating tumor cells after adjuvant chemotherapy in patients with early breast cancerJ Clin Oncol200927132177218419332733
  • LacroixMSignificance, detection and markers of disseminated breast cancer cellsEndocr Relat Cancer20061341033106717158753
  • StathopoulouAGiziAPerrakiMReal-time quantification of CK-19 mRNA-positive cells in peripheral blood of breast cancer patients using the LightCycler systemClin Cancer Res20039145145515114613993
  • RingAEZabagloLOrmerodMGSmithIEDowsettMDetection of circulating epithelial cells in the blood of patients with breast cancer: comparison of three techniquesBr J Cancer200592590691215714202
  • van der AuweraIPeetersDBenoyIHCirculating tumour cell detection: a direct comparison between the CellSearch System, the AdnaTest and CK-19/mammaglobin RT-PCR in patients with metastatic breast cancerBr J Cancer2010102227628419953098
  • ZhaoSLiuYZhangQThe prognostic role of circulating tumor cells (CTCs) detected by RT-PCR in breast cancer: a meta-analysis of published literatureBreast Cancer Res Treat2011130380981621311967
  • GrünewaldKHaunMUrbanekMMammaglobin gene expression: a superior marker of breast cancer cells in peripheral blood in comparison to epidermal-growth-factor receptor and cytokeratin-19Lab Invest20008071071107710908152
  • NtouliaMStathopoulouAIgnatiadisMDetection of mamma-globin A-mRNA-positive circulating tumor cells in peripheral blood of patients with operable breast cancer with nested RT-PCRClin Biochem200639987988716925986
  • WangZSpauldingBSienkoAMammaglobin, a valuable diagnostic marker for metastatic breast carcinomaInt J Clin Exp Pathol20092438438919158935
  • GroverPKCumminsAGPriceTJRoberts-ThomsonICHardinghamJECirculating tumour cells: the evolving concept and the inadequacy of their enrichment by EpCAM-based methodology for basic and clinical cancer researchAnn Oncol20142581506151624651410
  • JaegerBASJueckstockJAndergassenUEvaluation of two different analytical methods for circulating tumor cell detection in peripheral blood of patients with primary breast cancerBiomed Res Int201420147111
  • FabisiewiczAKulikJKoberPBrewczyńskaEPieńkowskiTSiedleckiJADetection of circulating breast cancer cells in peripheral blood by a two-marker reverse transcriptase-polymerase chain reaction assayActa Biochim Pol200451374775515448736
  • ChekhunSBezdenezhnykhNShvetsJLukianovaNExpression of biomarkers related to cell adhesion, metastasis and invasion of breast cancer cell lines of different molecular subtypeExp Oncol201335317417924084454
  • Al JoudiFSHuman mammaglobin in breast cancer: a brief review of its clinical utilityIndian J Med Res2014139567568525027076
  • RaicaMCîmpeanAMMecheAAlexaASuciuCMures¸anAAnalysis of the immunohistochemical expression of mammaglobin A in primary breast carcinoma and lymph node metastasisRom J Morphol Embryol200950334134719690758
  • RoncellaSFerroPBacigalupoBRelationship between human mammaglobin mRNA expression in breast cancer tissue and clinico-pathologic features of the tumorsJ Exp Clin Cancer Res2006251657216761620
  • Al-JoudiFSKaidFAKIshakIMohamedNOsmanKAliasIZExpression of human mammaglobin and clinicopathologic correlations in breast cancer: the findings in MalaysiaIndian J Pathol Microbiol201154228428921623075
  • LeeG-WKimJ-YKohE-HPlasma human mammaglobin mRNA associated with poor outcome in patients with breast cancerGenet Mol Res20121144034404223212340
  • NakagawaTMartinezSRGotoYDetection of circulating tumor cells in early-stage breast cancer metastasis to axillary lymph nodesClin Cancer Res200713144105411017634536
  • WatsonMADarrowCZimonjicDBPopescuNCFlemingTPStructure and transcriptional regulation of the human mammaglobin gene, a breast cancer associated member of the utero-globin gene family localized to chromosome 11q13Oncogene19981668178249488047
  • ZehentnerBKPersingDHDemeAMammaglobin as a novel breast cancer biomarker: multigene reverse transcription-PCR assay and sandwich ELISAClin Chem200450112069207615375015