Real-world comparison of the effectiveness and safety of different bowel preparation agents

, , , , &
Pages 289-299 | Published online: 16 Aug 2018

Abstract

Background and aims

Proper bowel cleansing is necessary prior to colonoscopy, but poor tolerability to bowel preparation agents may increase the odds of poor cleansing and incomplete screenings. The aim of this study was to evaluate the real-world effectiveness and safety of bowel preparation agents.

Methods

Claims data were extracted for individuals who had a screening colonoscopy from July 1, 2012, to June 30, 2015, were ≥18 years of age, and who could be observed ≥6 months before and ≥3 months after the screening. Data were stratified by agent class, including over-the-counter (OTC), low-volume (LV), and high-volume (HV) agents. Rates of incomplete screenings, repeat screenings, and hospitalizations were reported. Multivariate logistic regression was conducted to compare outcomes for sodium picosulfate, magnesium oxide, and citric acid (P/MC) vs other agents.

Results

Of 2.8 million individuals, 71.5% were average risk and 28.5% were high risk for colorectal cancer. Rates of use were 2.8% for P/MC, 30.1% for other LV agents, 9.4% for HV agents, and 56.6% for OTC agents. All individuals who used P/MC had significantly lower odds of incomplete screenings compared to those who used other LV agents or HV agents (P<0.05). In average-risk patients, rates of 30- and 90-day repeat screenings were highest for the P/MC group (16.7% and 23.0%, respectively) compared to other agents. Across all patient analysis groups, the rates of hospitalizations for hyponatremia or dehydration were much higher for those who used an OTC bowel preparation agent compared to those who used LV or HV agents, or P/MC.

Conclusion

P/MC was associated with lower rates of incomplete colonoscopy and higher rates of repeat screenings, suggesting it was better tolerated than other agents. OTC agents were associated with higher rates of hospitalizations.

Introduction

Colorectal cancer (CRC) screening is recommended for prevention and early detection of CRC.Citation1,Citation2 Individuals with no personal or family history of CRC or polyps are advised to undergo screening every 10 years, while those who are at higher risk (those with a personal/family history of colorectal disease, including those with inflammatory bowel disease [IBD]) should be screened more often.Citation3

Colonoscopy is the most common method for CRC screening in the United States (US) and is associated with a decreased incidence of CRC and death due to CRC.Citation4Citation6 Proper bowel cleansing is necessary to achieve a successful colonoscopy.Citation7Citation10

Unfortunately, bowel preparation is widely viewed by patients as a significant negative aspect of the colonoscopy procedure.Citation11Citation13 Poor tolerability for bowel preparation agents may increase the odds of a patient not taking the full dose, which can lead to poor bowel preparation that prevents screening. A survey of patients undergoing colonoscopy found that poor tolerability to bowel preparation agents was associated with a lower quality screen and fewer polyps detected.Citation14 A meta-analysis of bowel preparation agents administered as a split dose showed that their use significantly increased the adequacy of bowel preparations, compared to day-before dosing, and that patients taking a split dose had significantly higher willingness to repeat preparation with the same agent; similar results were seen for same-day dosing.Citation15,Citation16

An earlier claims study examined the hospitalizations and need for repeat screenings among patients using commonly prescribed prescription bowel preparation agents.Citation17 However, that study did not include over-the-counter (OTC) preparation agents, which account for a significant portion of the bowel preparation agents used for screening colonoscopies.Citation18 The study also did not assess the rate of incomplete screening colonoscopies or data from high-risk individuals, thus giving only a partial view of the real-world effectiveness and safety of bowel preparation agents.

The aim of the current study was to evaluate the real-world effectiveness and safety of bowel preparation agents by measuring rates of incomplete screenings, repeat screenings, and hospitalizations after screenings, stratified by bowel preparation agent, including in high-risk individuals.

Methods

Study design

This was a retrospective cohort study of outcomes of screening colonoscopy in individuals using different bowel preparation agents, identified in employer-based health insurance claims. De-identified data, licensed from the Truven Health Analytics Commercial and Medicare Supplemental MarketScan databases (Truven Health Analytics, Ann Arbor, MI, USA), were extracted for the period from July 1, 2012, through June 30, 2015. This study was exempt from IRB approval as it did not involve any biomedical research with human subjects.

The index screening was defined as the first screening colonoscopy identified for the individual during the study period. Screening colonoscopies were identified based on ICD, ninth revision, Clinical Modification (ICD-9-CM) procedure codes: 4522, 4524, 4523, 44355, 44388–44394, 45378–45387, 45391, 45392, G0105, G0121, G0104, G0106, or G0120. Screening colonoscopies identified by these codes were also included if they had a modifier code of 33 or PT, indicating one or multiple polyp(s) were removed. High-risk individuals were identified by a screening procedure code of V1005, V1006, V1272, V160, V1851, V7641, V7651, V8409, or G0105. All other colonoscopies were considered to be diagnostic, rather than screening, procedures and were not included in the study.

Data from screening colonoscopies using sodium picosulfate, magnesium oxide, and citric acid (P/MC) low-volume bowel preparation agents were compared to 1) all other low-volume (LV) agents as a class, 2) the two most commonly prescribed LV agents (oral sulfate solution [OSS]; polyethylene glycol plus ascorbic acid [PEG + AA]), 3) high-volume (HV) agents, and 4) OTC agents.

LV agents were defined as those with <4 L solution; HV agents were those with ≥4 L solution (based on their approved labeling and directions for use).Citation19,Citation20 Tablet-based agents were categorized as “other bowel preparation agents.” In the US, OTC medicines are not covered by health insurance and will not show up in administrative claims databases. Therefore, the lack of a prescription filled in the claims database for a bowel preparation agent within 90 days before the screening was used to identify individuals assumed to have used an OTC preparation agent.

Study population

Individuals were included in the study if they had at least one colonoscopy during the study period, were ≥18 years of age at the time of the index screening, and could be observed for at least 6 months before and at least 3 months after the index screening in the database.

Individuals were stratified by the presence or absence of risk factors for CRC into those who were considered to have average risk (no personal/family history) and those who were deemed high-risk (with a personal/family history of colorectal disease). A subset of individuals in the high-risk group with IBD was analyzed separately. Individuals with IBD were identified by ICD-9-CM diagnosis codes for ulcerative colitis: 560.89, 556.0, 556.1, 556.2, 556.3, 556.4, 556.5, 556.6, 556.8, or 556.9; or Crohn’s disease: 555.0, 555.1, 555.2, or 555.9.

De-identified data were extracted for each individual: age; sex; health status (measured by the Charlson comorbidity index [CCI]); comorbidities (diabetes, heart disease, cerebrovascular disease, renal disease, liver disease, prior cancer); and prescription medication use. The CCI is widely used as a measure of a person’s health status that summarizes comorbidities for each individual on the basis of diagnosis codes found in administrative claims data, with higher scores indicative of poorer health.Citation21,Citation22

Outcomes

The effectiveness outcomes examined in this study were the number of incomplete screenings, and the number of return screenings following an incomplete screening. Incomplete screenings were defined as screening colonoscopies with a procedure modifier code of 22, 52, 53, 73, or 74. A repeat screening was defined as a second screening colonoscopy that occurred within 30 days or 90 days of the index screening. A second screening colonoscopy that occurred within 90 days of an incomplete screening indicated a return due to the failure of the index screening, as the guideline-recommended regular screening interval is at least 1 year or longer.Citation1Citation3,Citation23

Adverse events included in this study were hospitalizations due to hyponatremia (identified by ICD-9-CM diagnosis code 276.1 or 276.0) or to dehydration (identified by ICD-9-CM diagnosis code 276.50, 276.51, or 276.52) that occurred within 10 days of the index screening. Fluid levels in an individual following a bowel preparation are a particular concern for those using LV agents, and these hospitalizations would likely indicate an issue with product safety that could have been associated with the preparation agent.

Statistical analysis

Descriptive statistics (mean, SD, range) were calculated for the demographic and clinical characteristics in each cohort. Rates of incomplete screenings, repeat screenings, and hospitalizations due to adverse events were calculated. The rate of repeat screenings was calculated as a proportion of the number of incomplete screenings.

Multivariate logistic regression, adjusting for age, sex, illness burden (CCI), comorbidities, and medication use, was conducted to evaluate whether the outcomes were significantly different for individuals who received P/MC compared to HV agents, P/MC compared to other LV agents, P/MC compared to OTC agents, and P/MC compared to OSS or PEG + AA. In all comparisons, the LV class data did not include P/MC. Point estimates were examined for age and sex covariates to determine the effect, if any, of these variables on the rates of incomplete and repeat screenings.

All analyses were conducted using SAS Version 9.4.

Results

Demographic characteristics

A total of 2.8 million individuals were included in the study (). Most individuals (71.5%) were categorized as having average risk for CRC, while 28.5% were high risk. Of the high-risk group, 4.5% had IBD and 24.0% had a non-IBD personal history of colorectal disease or any family history of colorectal disease.

Table 1 Demographic characteristics, by risk group and agent class

In the average-risk group (n=2,013,880), 54.7% were female, the mean (SD) age was 55.8 (11.1) years, and the mean (SD) CCI score was 0.47 (1.04) (). In this group, 56.5% used an OTC preparation agent, 30.2% used a LV agent, and 9.5% used a HV agent ().

The high-risk group and the IBD subgroup had similar demographic characteristics and patterns of use for the classes of bowel preparation agents ().

Average-risk group

Incomplete screenings

The rates of incomplete screening colonoscopies were 0.93% among individuals who used LV agents, 0.92% with HV agents, and 0.79% with OTC agents (). For the three most frequently used LV agents, the rates of incomplete screenings were 0.76% for P/MC, 0.88% for OSS, and 1.01% for PEG + AA. In multivariate analyses that controlled for age, sex, illness burden, comorbidities, and medication use, individuals who used P/MC had significantly lower odds of incomplete screenings compared to other LV agents as a class (P<0.0001), HV agents (P<0.01), OSS (P<0.01), or PEG + AA (P<0.0001) (). There was no significant difference in the odds of an incomplete screening between individuals who used P/MC or OTC bowel preparation agents.

Table 2 Effectiveness outcomes for average-risk individuals, by agent class and the three most frequently used LV agents

Among average-risk patients, women were 1.4–1.5 times more likely to have an incomplete screen, compared to men (P<0.0001; Table S1). Age did not have a significant effect on the odds of an incomplete screen, except in the cohort comparison of P/MC with OTC, where the odds of an incomplete screen was 1.004 (P=0.0378) with each additional year of age.

Repeat screenings

Of the individuals who had an incomplete screening, the rates of 30- and 90-day repeat screenings were highest for those using P/MC (16.7% and 23.0%, respectively; ). Results of multivariate analyses showed that individuals who used P/MC had 1.9 times the odds of returning for a repeat screening as individuals who used other LV agents (P<0.0001), 1.5 times the odds as those who used an HV agent (P<0.01), 2.6 times the odds of returning as those who used OSS (P<0.0001), and 1.5 times the odds as those who used PEG + AA (P<0.01) (). There was no significant difference between individuals who used P/MC or OTC bowel preparation agents in the odds of repeat screening following an incomplete screen.

Female sex was significantly associated with lower odds of returning for a repeat screen in patients who used an OTC agent or P/MC (OR: 0.788; 95% CI [0.697, 0.89]; P=0.0001; Table S1). Each additional year of age was associated with slightly lower odds of returning for a repeat screen in all cohorts (OR =0.99; P<0.05) except for P/MC vs OSS.

Hospitalizations

The rates of hospitalizations within 10 days of the index event due to hyponatremia or dehydration were low (<0.1%) across all classes. However, the rates of hospitalizations were much higher for individuals who used an OTC bowel preparation agent than those who used either LV or HV agents or P/MC (). There were no significant differences in the odds of hyponatremia between individuals using P/MC or other agents or agent classes, likely because of the very small number of adverse events recorded. ORs for hospitalizations due to dehydration were not calculated because there were no events reported in individuals using P/MC.

Table 3 Rates of hospitalizations in average-risk individuals, by agent class and the three most frequently used LV agents

High-risk group

Incomplete screenings

In high-risk individuals, the rates of incomplete screenings were 0.81% for P/MC, 1.02% for OSS, and 1.20% for PEG + AA (). In multivariate analyses, individuals who used P/MC had significantly lower odds of incomplete screenings compared to those using other LV agents as a class (P<0.0001), HV agents (P<0.05), OSS (P<0.0001), or PEG + AA (P<0.0001). There was no significant difference in the odds of an incomplete screening between individuals using P/MC or OTC bowel preparation agents ().

Table 4 Effectiveness outcomes for high-risk individuals, by agent class and the three most frequently used LV agents

Among high-risk patients, women in all cohorts were 1.4–1.5 times more likely to have an incomplete screen, compared to men (P<0.0001; Table S2). In the P/MC vs OTC cohort, each additional year of age was associated with lower odds of an incomplete screening (OR: 0.994; 95% CI [0.991, 0.997]; P<0.0001).

Repeat screenings

Of the high-risk individuals who had an incomplete screening, the rates of 30- and 90-day repeat screenings were highest for those using P/MC (18.3% and 23.0%, respectively; ). Multivariate analyses showed that individuals who used P/MC had 2.6 times the odds of returning for a repeat screening as individuals who used OSS (P<0.0001) and 1.9 times the odds as individuals who used PEG + AA (P<0.01). When comparing P/MC to the classes of bowel preparation agents, individuals who used P/MC had 2.0 (P<0.01), 2.1 (P<0.01), and 1.6 (P<0.05) times the odds of returning for a repeat screening within 90 days of the index screening as individuals using LV, HV, or OTC bowel preparation agents, respectively ().

There were no significant differences between men and women in the odds of returning for a repeat screening (Table S2). Age was significantly associated with lower odds of a repeat screening for the P/MC vs HV cohort (OR: 0.973, 95% CI [0.953, 0.994]; P=0.0122).

Hospitalizations

Similar patterns were seen in the high-risk group as in the average risk group for hospitalizations due to hyponatremia and dehydration (). Rates of hospitalizations were low and comparable across P/MC, OSS, and PEG + AA groups, while rates of hospitalizations were higher for the OTC group.

Table 5 Rates of hospitalizations for high-risk individuals, by agent class and the three most frequently used LV agents

IBD subgroup

Incomplete screenings

For high-risk individuals with IBD, the rates of incomplete screening colonoscopies were 0.74% for P/MC, 1.32% for OSS, and 1.43% for PEG + AA (). In multivariate analyses, individuals who used P/MC had significantly lower odds of incomplete screenings compared to other LV agents as a class, to HV agents, OTC agents, and compared to OSS and PEG + AA (all P<0.01; ). Individuals with IBD who used P/MC had approximately half the odds of an incomplete screening compared to all classes and agents.

Table 6 Effectiveness outcomes for the IBD subgroup of high-risk individuals, by agent class and the three most frequently used LV agents

Among patients with IBD, women were 1.1–1.5 times more likely to have an incomplete screen, compared to men, although these estimates were not all significant (Table S3). Age did not have a significant effect on odds of incomplete screening except for the P/MC vs OSS cohort (OR: 1.011; 95% CI [1.001, 1.021]; P=0.0301).

Repeat screenings

Of the individuals with IBD who had an incomplete screening, the rates of 30- and 90-day repeat screenings were highest for P/MC (18.5% and 22.2%, respectively; ). There were no significant differences between agent classes or agents in the odds of returning for a repeat screening colonoscopy, likely due to the small numbers of individuals in this analysis.

Sex was not a significant factor in returning for a repeat screening after an incomplete one, except for the P/MC vs OTC cohort, where women had lower odds of returning for a repeat screen within 90 days, compared to men (OR: 0.605; 95% CI [0.403, 0.908]; P=0.02; Table S3). Age did not have a significant effect on the odds of returning after an incomplete screen.

Hospitalizations

There were no hospitalizations due to dehydration or hyponatremia recorded for individuals with IBD who used P/MC, OSS, or PEG + AA for bowel preparation before the index screening (). OTC agents were associated with higher rates of hospitalizations than the other bowel preparation agents.

Table 7 Rates of hospitalizations for the IBD subgroup of high-risk individuals, by agent class and the 3 most frequently used LV agents

Discussion

Significantly fewer individuals who used P/MC as a bowel preparation agent prior to their colonoscopy had an incomplete screening, indicating that P/MC was as efficacious as or more efficacious than other commonly used bowel preparation agents. These differences in rates of incomplete screenings were significant across all patient groups (average-risk, high-risk, and IBD) and compared with other LV agents, HV agents, and OTC agents. Of those who did have an incomplete screening, more individuals who used P/MC for their index screening returned for a repeat screening within the specified period compared to individuals who used other LV agents and those who used HV agents, suggesting better tolerability of P/MC for bowel preparation. These differences were significant across all comparisons to prescription preparation agents.

The outcomes in this study may have been affected by how each agent was taken, ie, whether it was consumed as a split dose or day before dose, and the bowel preparation that was used with the repeat screening and the outcomes of the repeat screening.

Reports in the literature indicate that approximately 20% of all colonoscopies show inadequate bowel preparation.Citation10,Citation13,Citation23 Recent studies of single center medical records showed an average rate of inadequate bowel preparation of 9–19.5%, with the inadequacy varying depending on the bowel preparation agent.Citation24,Citation25 However, physicians may decide to perform intra-procedure cleansing to enable better visibility of the colonic mucosa and complete the colonoscopy, rather than risk the individual not returning for a repeat screening after an incomplete colonoscopy.Citation10 Therefore, the rates of incomplete screenings measured in this study may reflect this practice and lead to rates of incomplete screenings that are lower than rates of incomplete bowel preparations. Additionally, this study included only colonoscopies performed on an outpatient basis, which comprise the majority of colonoscopies and tend to have lower incomplete rates than those performed as inpatient procedures.Citation26 Clinical trials of bowel preparation agents indicate that in approximately 1–5% of cases, the cecum could not be intubated (incomplete colonoscopy), which is similar to the rates seen in this study.Citation27,Citation28

There was no evidence of any new safety issues associated with P/MC in real-world use compared to what has been reported in randomized, clinical trials.Citation28 The rates of hospitalizations in this study were similar between P/MC and other LV agents. Across all risk groups, OTC agents were associated with the highest rates of hospitalizations due to hyponatremia or dehydration. This may be due to a lack of supplemental electrolytes in OTC preparation agents that are provided in some prescription bowel preparation solutions or variability in fluid intake as part of the bowel preparation procedure. This latter possibility may be related to a lack of standardized instructions for OTC bowel preparation agents.Citation10

The high-risk group, as well as the IBD subset of the high-risk group, had higher rates of incomplete screenings than the average-risk group in this study, which may reflect a lower tolerability for more frequent bowel preparations among these patients. In high-risk individuals, including those with IBD, compliance with bowel preparation is particularly critical.Citation29,Citation30 However, the tolerability of bowel preparation agents may deter these individuals from returning as needed for screenings.Citation30,Citation31 Missed screening colonoscopies can have negative consequences for polyp detection and long-term health.Citation7Citation9,Citation32 Rates of repeat screenings in the high-risk group in this analysis were higher for individuals using P/MC, suggesting that they were more likely to return for screening than those using other bowel preparation agents.

OTC bowel preparation agents were the most commonly used agents (57%) for screening colonoscopies in our sample. Another claims study representing just over 500,000 colonoscopies showed slightly lower rates of OTC bowel preparation agent use (43%; as defined by the lack of a prescription bowel preparation agent within 30 days before a procedure) than that observed here.Citation18 In our study, OTC agents were defined as a lack of prescription for a bowel preparation agent within 90 days before screening. Most of the individuals in this group likely used OTC bowel preparation agents, but it is possible that some used prescription bowel preparation agents that they received as samples from their physicians; this would not have been detected in claims data. Because there is no claims code to indicate an OTC agent, the lack of a prescription was chosen as the best surrogate marker to approximate OTC agent use.

Limitations of the current study include the use of incomplete screenings as a surrogate for the effectiveness of a bowel preparation agent. This measure may also include individuals who had an incomplete screening due to nonadherence to the bowel preparation instructions; or technical problems related to anatomy, such as a fixed or tortuous colon, or ones secondary to a previous abdominal or pelvic surgery. The study also did not quantify either the impact of an incomplete screening or not returning for a repeat screening on any long-term health outcomes. The time period of 30 or 90 days after the index screening was an arbitrary window used to quantify how many individuals return after an incomplete screening, but these time frames may not have captured all of the individuals who did eventually return. An administrative claims study showed that rates of long-term repeat screening colonoscopies (up to 4 years after index screening) were 12.6% in commercially insured patients and 19.8% in Medicare-insured patients.Citation18

Additionally, there was no measure of dosing for each agent (ie, how much was actually taken vs how much was prescribed); thus, it remains unknown how much solution is associated with a success or failure of the bowel preparation. Direct measures of patient preferences or tolerability were not acquired in this study, and the rate of repeat screenings after an incomplete one are taken as a surrogate of patient tolerability.

Conclusion

This study showed that P/MC was associated with lower rates of incomplete screening colonoscopy in all patient risk groups and higher rates of a repeat screening within 30 and 90 days of an incomplete screening. These findings suggest that bowel preparation with P/MC was more effective in the index screening and less of a deterrent for patients needing repeat screenings. Overall, high-risk individuals had higher rates of incomplete screenings than average-risk individuals, which may necessitate more patient education on the part of the clinician. The safety of P/MC was comparable to that of other prescription agents. While OTC agents were used for more than half of the bowel preparations in this study, OTC agents were associated with higher rates of hospitalizations than other agents, which could be caused by the agent itself. Based on the relative effectiveness and safety advantages in average- and high-risk populations, P/MC should be considered for all bowel preparations for CRC screening. Standardization and improved clarity of the instructions for OTC bowel preparation agents may help avoid some of the hydration or electrolyte complications associated with these agents.

Author contributions

All authors contributed toward data analysis, drafting and revising the paper, and agree to be accountable for all aspects of the work.

Acknowledgments

This study was funded by Ferring Pharmaceuticals Inc., Parsippany, NJ, USA. Medical writing and editorial support was provided by Agnella Izzo Matic, PhD, CMPP, AIM Biomedical and was funded by Ferring Pharmaceuticals Inc.

Supplementary materials

Table S1 Point estimates of sex and age covariate effects in multivariate analyses – average-risk group

Table S2 Point estimates of sex and age covariate effects in multivariate analyses – high-risk group

Table S3 Point estimates of sex and age covariate effects in multivariate analyses – IBD subgroup

Disclosure

Dr Bertiger has served as a consultant and has been a part of the speakers bureau for Ferring Pharmaceuticals Inc. Dr Dah-dal and Dr Brogadir are employees of Ferring Pharmaceuticals Inc. Dr Sacks, Mr Cyr, and Mr Sharma are employees of Precision Xtract and provided analysis services to Ferring Pharmaceuticals Inc. The authors report no other conflicts of interest in this work.

References

  • RexDKJohnsonDAAndersonJCAmerican College of Gastroenterology guidelines for colorectal cancer screening 2009 [corrected]Am J Gastroenterol2009104373975019240699
  • US Preventive Services Task ForceBibbins-DomingoKGrossmanDCScreening for colorectal cancer: US Preventive Services Task Force Recommendation StatementJAMA2016315232564257527304597
  • ItzkowitzSHPresentDHCrohn’s and Colitis Foundation of America Colon Cancer in IBD Study Group. Consensus conference: colorectal cancer screening and surveillance in inflammatory bowel diseaseInflamm Bowel Dis200511331432115735438
  • BrennerHChang-ClaudeJSeilerCMHoffmeisterMLong-term risk of colorectal cancer after negative colonoscopyJ Clin Oncol201129283761376721876077
  • ChenCStockCHoffmeisterMBrennerHPublic health impact of colonoscopy use on colorectal cancer mortality in Germany and the United StatesGastrointest Endosc201887121322128431951
  • MurphyCCSandlerRSSanoffHKYangYCLundJLBaronJADecrease in incidence of colorectal cancer among individuals 50 years or older after recommendations for population-based screeningClin Gastroenterol Hepatol201715690390927609707
  • ChokshiRVHovisCEHollanderTEarlyDSWangJSPrevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopyGastrointest Endosc20127561197120322381531
  • HarewoodGCSharmaVKde GarmoPImpact of colonoscopy preparation quality on detection of suspected colonic neoplasiaGastrointest Endosc2003581767912838225
  • LebwohlBKastrinosFGlickMRosenbaumAJWangTNeugutAIThe impact of suboptimal bowel preparation on adenoma miss rates and the factors associated with early repeat colonoscopyGastrointest Endosc20117361207121421481857
  • ASGE Standards of Practice CommitteeSaltzmanJRCashBDPashaSFBowel preparation before colonoscopyGastrointest Endosc201581478179425595062
  • KoCWRiffleSShapiroJAIncidence of minor complications and time lost from normal activities after screening or surveillance colonoscopyGastrointest Endosc200765464865617173914
  • NicholsonFBKormanMGAcceptance of flexible sigmoidoscopy and colonoscopy for screening and surveillance in colorectal cancer preventionJ Med Screen2005122899515949120
  • RexDKOptimal bowel preparation – a practical guide for cliniciansNat Rev Gastroenterol Hepatol201411741942524686267
  • HoltEWYimamKKMaHShawRESundbergRAVerhilleMSPatient tolerability of bowel preparation is associated with polyp detection rate during colonoscopyJ Gastrointestin Liver Dis201423213514024949604
  • MartelMBarkunANMenardCRestelliniSKheradOVanasseASplit-dose preparations are superior to day-before bowel cleansing regimens: a meta-analysisGastroenterology20151491798825863216
  • AvalosDJCastroFJZuckermanMJBowel preparations administered the morning of colonoscopy provide similar efficacy to a split dose regimen: a meta analysisJ Clin Gastroenterol Epub201796
  • YoungLESacksNCCyrPLSharmaADahdalDNComparison of claims data on hospitalization rates and repeat procedures in patients receiving a bowel preparation prior to colonoscopySAGE Open Med20175205031211772799928894587
  • PyensonBScammellCBrouletteJCosts and repeat rates associated with colonoscopy observed in medical claims for commercial and Medicare populationsBMC Health Serv Res2014149224572047
  • WexnerSDBeckDEBaronTHConsensus document on bowel preparation for colonoscopyGastrointest Endosc200663789490916733101
  • KimHNRajuGSBowel preparation and colonoscopy technique to detect non-polypoid colorectal neoplasmsGastrointest Endosc Clin N Am201020343744820656242
  • CharlsonMEPompeiPAlesKLMackenzieCRA new method of classifying prognostic comorbidity in longitudinal studies: development and validationJ Chronic Dis19874053733833558716
  • QuanHLiBCourisCMUpdating and validating the Charlson comorbidity index and score for risk adjustment in hospital discharge abstracts using data from 6 countriesAm J Epidemiol2011173667668221330339
  • JohnsonDABarkunANCohenLBOptimizing adequacy of bowel cleansing for colonoscopy: recommendations from the US multi-society task force on colorectal cancerGastroenterology2014147490392425239068
  • SarvepalliSGarberARizkM923 Adjusted comparison of commercial bowel preparations based on inadequacy of bowel preparation in outpatient settingsGastrointest Endosc2018876AB127
  • GuPLewDKoJZMo1630 – comparing the real-world effectiveness of competing colonoscopy bowel preparations on bowel cleansing and adenoma detection: results of a large prospective trialGastroenterology20181546775770
  • EnnsRKrygierDThe in-patient colonoscopy: a difficult endeavorCan J Gastroenterol2008221190090219018333
  • BitounAPonchonTBarthetMResults of a prospective randomised multicentre controlled trial comparing a new 2-L ascorbic acid plus polyethylene glycol and electrolyte solution vs sodium phosphate solution in patients undergoing elective colonoscopyAliment Pharmacol Ther20062411–121631164217094774
  • KatzPORexDKEpsteinMA dual-action, low-volume bowel cleanser administered the day before colonoscopy: results from the SEE CLEAR II studyAm J Gastroenterol2013108340140923318484
  • NettAVelayosFMcquaidKQuality bowel preparation for surveillance colonoscopy in patients with inflammatory bowel disease is a mustGastrointest Endosc Clin N Am201424337939224975529
  • RestelliniSKheradOBessissowTSystematic review and meta-analysis of colon cleansing preparations in patients with inflammatory bowel diseaseWorld J Gastroenterol201723325994600228932092
  • DentersMJSchreuderMDeplaACPatients’ perception of colonoscopy: patients with inflammatory bowel disease and irritable bowel syndrome experience the largest burdenEur J Gastroenterol Hepatol201325896497223660935
  • SulzMCKrögerAPrakashMManserCNHeinrichHMisselwitzBMeta-analysis of the effect of bowel preparation on adenoma detection: early adenomas affected stronger than advanced adenomasPLoS One2017116e0154149