Original Research

Comparison of distinctive models for calculating an interlobar emphysema heterogeneity index in patients prior to endoscopic lung volume reduction

, , , , &
Pages 1631-1640 | Published online: 01 Jun 2017

Abstract

Background

The degree of interlobar emphysema heterogeneity is thought to play an important role in the outcome of endoscopic lung volume reduction (ELVR) therapy of patients with advanced COPD. There are multiple ways one could possibly define interlobar emphysema heterogeneity, and there is no standardized definition.

Purpose

The aim of this study was to derive a formula for calculating an interlobar emphysema heterogeneity index (HI) when evaluating a patient for ELVR. Furthermore, an attempt was made to identify a threshold for relevant interlobar emphysema heterogeneity with regard to ELVR.

Patients and methods

We retrospectively analyzed 50 patients who had undergone technically successful ELVR with placement of one-way valves at our institution and had received lung function tests and computed tomography scans before and after treatment. Predictive accuracy of the different methods for HI calculation was assessed with receiver-operating characteristic curve analysis, assuming a minimum difference in forced expiratory volume in 1 second of 100 mL to indicate a clinically important change.

Results

The HI defined as emphysema score of the targeted lobe (TL) minus emphysema score of the ipsilateral nontargeted lobe disregarding the middle lobe yielded the best predicative accuracy (AUC =0.73, P=0.008). The HI defined as emphysema score of the TL minus emphysema score of the lung without the TL showed a similarly good predictive accuracy (AUC =0.72, P=0.009). Subgroup analysis suggests that the impact of interlobar emphysema heterogeneity is of greater importance in patients with upper lobe predominant emphysema than in patients with lower lobe predominant emphysema.

Conclusion

This study reveals the most appropriate ways of calculating an interlobar emphysema heterogeneity with regard to ELVR.

Introduction

In recent years, more and more insight has been gained into endoscopic lung volume reduction (ELVR) as a treatment option for patients with severe COPD and concomitant emphysema.Citation1Citation10 Several criteria for identifying patients who might benefit from ELVR and the lung lobe to be treated to achieve the best outcome have been proposed. An important criterion is interlobar emphysema heterogeneity.Citation1,Citation11,Citation12 Put simply, the impact of interlobar emphysema heterogeneity on the outcome of ELVR can be summed up as follows: if the lung lobes differ in the amount of emphysema, that is, the amount of damaged lung parenchyma, and the most afflicted lung lobe is eliminated with ELVR by inducing atelectasis, outcome is better than if the entire lung is affected equally and one lobe is removed by ELVR. While many studies found a significant impact of interlobar emphysema heterogeneity on outcome after ELVR, others did not.Citation13

There are many different ways one could possibly define interlobar emphysema heterogeneity, and a standardized definition does not exist. In the VENT trial, the “percentage of heterogeneity was defined as the difference in quantitative emphysema score between the targeted lobe and the ipsilateral adjacent nontargeted lobe” disregarding the middle lobe.Citation1 On the other hand, Valipour et al, for example, defined the interlobar heterogeneity index (HI) as the tissue destruction of the targeted lobe (TL) divided by the tissue destruction of the ipsilateral nontargeted (INTL) lobe, disregarding the middle lobe and lingual.Citation14

The aim of this study was to find a definition of HI that best predicts the outcome of ELVR. To that end, we determined the HI in six different ways that we found theoretically reasonable with regard to ELVR and compared the results with the improvement of the forced expiratory volume in 1 second (FEV1) after ELVR by performing a receiver-operating characteristic (ROC) analysis.

We focused on FEV1 as the output parameter, for it seems to be the only output parameter that emphysema heterogeneity has a relevant impact on as shown in the study recently published by Thomsen et al.Citation12 Nevertheless, other output parameters such as the residual volume (RV), the St George’s Respiratory Questionnaire (SGRQ) and the 6-minute walk test (6MWT) were briefly analyzed, too, using the same statistical method.

Patients and methods

The study was approved by the ethics committee of the Charité (EA1/213/16). It was a retrospective study from medical records. All patients were anonymized prior to data analysis. Based on the votum of the local ethic committee, informed consent forms were not required for this study.

Patient population

We retrospectively analyzed 62 patients who underwent ELVR with placement of one-way silicone Zephyr valves (Pulmonx, Redwood City, CA, USA) at our institution and had received lung function tests and computed tomography (CT) scans acquired in inspiration before and after ELVR. All patients had advanced COPD with a FEV1 between 15% and 45% of the predicted value, a RV of at least 150% of the predicted value and a total lung capacity of >100% at baseline after reversibility testing. Most patients completed the SGRQ and the 6MWT before and after treatment. All patients had been nonsmokers for at least 3 months at the time of treatment, as proven by serum carboxyhemoglobin levels of <2%. The TL for ELVR was selected on the basis of visually estimated degree of emphysema, perfusion, and the absence of collateral ventilation determined by the Chartis system (Pulmonx) as described in the literature.Citation15,Citation16 All patients underwent ELVR with an entire lobe treated as recommended by previous studies.Citation3,Citation17 Out of the 62 patients analyzed in this study, 24 patients showed a tendency toward upper lobe predominant emphysema in visual assessment and received upper lobe treatment while 38 patients showed a tendency toward lower lobe predominant emphysema and received lower lobe treatment.

As described in the literature, a TL volume reduction of >350 mL was considered a technically successful treatment.Citation18 Out of the 62 evaluated patients, 12 did not meet this criterion and were therefore excluded, leaving 50 patients for the final analysis. Descriptive statistics of these 50 patients are summarized in .

Table 1 Descriptive statistics of the study population (n=50)

High-resolution computed tomography with quantitative analysis

All patients underwent a CT scan (Light Speed Ultra 8, General Electric, Boston, MA, USA) for target lobe selection and emphysema evaluation at baseline and for follow-up around 3 months after endoscopic valve implantation. The CT protocol was identical for all scans and included a slice thickness of 1.25 mm, 120 kVp, and 100 mAs. The scans were obtained in deep inspiration without intravenous contrast medium administration. We retrospectively performed quantitative analysis of the chest CT scans using the MeVisPULMO 3D software, version 3.42 (Fraunhofer MEVIS, Bremen, Germany), which enables quantification of emphysematous lung parenchyma by determining the emphysema score defined as the ratio of voxels with a density below a certain threshold to the total number of voxels in the region of interest.Citation19 We chose a threshold of −950 HU as proposed in previous studies.Citation20Citation22 Furthermore, we used the software for semiautomatic segmentation of the lung into the lung lobes (left upper lobe, left lower lobe, right upper lobe, right middle lobe, and right lower lobe) as described in the literature.Citation19,Citation23 See also example in .

Figure 1 Coronary 3D surface view of a processed HRCT scan of the lung acquired in inspiration depicting the lung lobes (semitransparent green, lower lobes; semitransparent red, upper lobe; semitransparent blue, right middle lobe) and voxels with a density below −950 HU (orange).

Note: The calculated emphysema scores, that is, percentages of voxels below −950 HU in a lung lobe to the total number of voxels in that lobe, were as follows: right upper lobe 26.4%, right middle lobe 16.0%, right lower lobe 14.9%, left upper lobe 27.8%, and left lower lobe 4.9%.
Abbreviation: HRCT, high-resolution computed tomography.
Figure 1 Coronary 3D surface view of a processed HRCT scan of the lung acquired in inspiration depicting the lung lobes (semitransparent green, lower lobes; semitransparent red, upper lobe; semitransparent blue, right middle lobe) and voxels with a density below −950 HU (orange).

Heterogeneity index

The HI was calculated from the emphysema scores of the lung lobes determined from CT scans acquired in inspiration. We used six different methods for calculating the HI based on definitions found in the literature and those we found theoretically feasible with regard to ELVR.Citation1,Citation14 The methods to calculate the HI differ in whether only the ipsilateral half of the lung or the entire lung is taken into account, whether the middle lobe of the right half of the lung is neglected or not, and whether the emphysema scores of the respective lung lobes are subtracted from each other or divided by each other. The exact definitions and main characteristics of the HIs used and compared in this analysis are summarized in and .

Table 2 Definitions of the six interlobar emphysema heterogeneity indices investigated in our study

Table 3 Overview of the major characteristics of the interlobar emphysema heterogeneity indices investigated in this study

In addition to that, there are other approaches to the HI like emphysema scores weighted for volume and HIs calculated from the tissue to air ratio. The latter version has been frequently used in bronchoscopic thermal vapor ablation trials.Citation24Citation26 In this study, both these approaches have been assessed separately in addition to the aforementioned HIs. The respective analyses are shown in Tables S1S3.

Statistical analysis

Predictive accuracy of the six different HIs was assessed by ROC curve analysis, assuming a minimum difference in FEV1 of 100 mL to indicate a minimal clinically important difference (MCID), as proposed in the literature.Citation27Citation30 In addition to that, other output parameters such as RV, 6MWT, and SGRQ were assessed with the same method using a MCID of 0. 31 L, 26 m, and 4 units, respectively, as suggested in the literature.Citation29,Citation30

The critical value was determined by the point on the ROC curve with the shortest distance to the upper left corner, that is, 100% sensitivity and 100% specificity.Citation31 This distance (D) was calculated using the following formula: D = √([1 − sensitivity]Citation2 + [1 − specificity]Citation2). In order to test for statistically significant differences, pairs of heterogeneity scores were compared using DeLong’s test for two correlated ROC curves. ROC analysis was performed using IBM SPSS Statistics 19.0.0 (IBM Corporation, Armonk, NY, USA) and R version 3.3.0 with the package “pROC” version 1.8. A P-value <0.05 was considered statistically significant.

Results

Of the 62 patients who had undergone ELVR at our institution and had received lung function tests and CT scans before and after ELVR, 50 showed a reduction in TL volume of >350 mL. Out of these 50 patients, 32 showed an increase in FEV1 of more than 100 mL after ELVR, that is, had a difference classified as clinically relevant, and 18 did not. In the ROC analysis, most of the six emphysema HIs investigated in this study showed statistically significant discriminatory capacity between clinically successful treatment, that is, an increase in FEV1 of >100 mL, and clinically unsuccessful treatment, that is, an increase in FEV1 of <100 mL (). HI 4, which is defined as emphysema score of the TL minus emphysema score of the INTL disregarding the middle lobe, yielded the best predicative accuracy (AUC =0.73, P=0.008). HI 6, which is defined as emphysema score of the TL minus emphysema score of the lung without the TL, showed a similarly good predictive accuracy (AUC =0.72, P=0.009). More generally speaking, the ROC analysis indicates that subtracting the percentages of emphysematous lung volume of the lobes in question yields a better predictive accuracy than dividing them. However, DeLong’s test showed no statistically significant differences between the ROC curves of HI 4 and HI 6 (P=0.543). The DeLong’s test did show statistically significant differences between the ROC curves of HI 1 and HI 2 (P=0.038), between the ROC curves of HI 2 and HI 4 (P=0.048), and HI 4 and HI 5 (P=0.015).

Table 4 ROC curve analysis to determine the predictive accuracy of the different HIs with respect to FEV1 improvement after ELVR

The critical value that can be considered to indicate relevant emphysema heterogeneity with regard to ELVR for the sensitivity and specificity level specified in is ~9.47% for HI 6 and ~16.55% for HI 4 ( and ). The critical value of HI 6=9.47 yielded similarly good sensitivity and specificity with a 0.66 and 0.78, respectively. The critical value of HI 4=16.55% may be better when striving for higher specificity (specificity =0.89) at the cost of lower sensitivity (sensitivity =0.47).

Table 5 Critical values of the HI 6 and HI 4 with their respective sensitivity and specificity that can be considered to identify relevant emphysema heterogeneity with regard to the prediction of significant improvement in FEV1 after ELVR

Figure 2 ROC of all HIs.

Note: *1–2 flag the values closest to the upper left corner.
Abbreviations: HI, heterogeneity index; ROC, receiver-operating characteristic.
Figure 2 ROC of all HIs.

Interestingly enough, in subgroup analysis of the patients with a tendency toward upper lobe predominant emphysema and upper lobe treatment HI 3, HI 4, HI 5, and HI 6 showed a statistically significant discriminatory capacity between clinically successful and unsuccessful treatment assessed by FEV1 increase and yielded better predictive accuracies than the analysis of the entire patient population with areas under the curve ranging from 0.82 to 0.88 ( and ). On the other hand, in subgroup analysis of patients with a tendency toward lower lobe predominant emphysema and lower lobe treatment, none of the HIs showed a statistically significant discriminatory capacity between clinically successful and unsuccessful treatment assessed in FEV1 increase ( and ).

Table 6 ROC curve analysis of all patients with a tendency toward upper lobe predominant emphysema and upper lobe treatment (n=24) to determine the predictive accuracy of the different HIs with respect to FEV1 improvement after ELVR, assuming an increase in FEV1 of 100 mL to indicate MCID

Table 7 ROC curve analysis of all patients with a tendency toward lower lobe predominant emphysema and lower lobe treatment (n=38) to determine the predictive accuracy of the different HIs with respect to FEV1 improvement after ELVR, assuming an increase in FEV1 of 100 mL to indicate MCID

Figure 3 Receiver-operating characteristic of all patients with a tendency toward upper lobe predominant emphysema and upper lobe treatment (n=24).

Abbreviation: HI, heterogeneity index.

Figure 3 Receiver-operating characteristic of all patients with a tendency toward upper lobe predominant emphysema and upper lobe treatment (n=24).Abbreviation: HI, heterogeneity index.

Figure 4 Receiver-operating characteristic of all patients with a tendency toward lower lobe predominant emphysema and lower lobe treatment (n=38).

Abbreviation: HI, heterogeneity index.
Figure 4 Receiver-operating characteristic of all patients with a tendency toward lower lobe predominant emphysema and lower lobe treatment (n=38).

In Table S4, we also show the results of the ROC analysis of all 62 patients; these results are similar yet slightly less compelling than the above-described analysis of the 50 patients, with a TL reduction of more than 350 mL.

None of the HIs showed a statistically significant discriminatory capacity between clinically successful and unsuccessful treatment assessed with other output parameters like RV, SGRQ, or 6MWT. Detailed results of the analyses with these output parameters are given in Tables S5S7.

Discussion

This study indicates that when determining an interlobar HI, generally speaking, subtracting the percentages of emphysematous lung volume of the lobes in question yields better predictive accuracy in ROC analysis than dividing them. Furthermore, the results suggest that disregarding the right middle lobe, as done in the VENT study by Sciurba et al, is reasonable.Citation1 Defining the HI as the emphysema score of the TL minus emphysema score of the lung without the TL, that is, HI 6, seems to be the most intuitive approach with regard to ELVR from our point of view, as the percentage of emphysematous lung tissue of the remaining lung is compared with that of the lung lobe about to be removed by means of atelectasis induction. Indeed, our results confirm that this definition yields good predictive accuracy in the ROC analysis (AUC =0.72, P=0.009). Interestingly enough, however, this is not the definition that was used in most of the major trials published in the literature.Citation1,Citation13,Citation32 Instead, in these studies, interlobar emphysema heterogeneity was defined as the emphysema score of the TL minus the emphysema score of the INTL, disregarding the middle lobe, that is, HI 4 in our analysis, which surprisingly enough also yielded the best predicative accuracy (AUC =0.73, P=0.008). However, when tested with DeLong’s test for two correlated ROC curves, H4 was only significantly different from HI 2 and HI 5, while HI 6 was not significantly different from any of the other HIs. The elucidated best definitions of HI should therefore be considered as a recommendation only and further studies are needed to validate the results.

When clinicians and investigators claim that interlobar emphysema heterogeneity has a relevant impact on the outcome of lung volume reduction and therefore should be taken into consideration when evaluating candidates for this treatment, it is only fair to ask what a relevant interlobar emphysema heterogeneity is. This study may give an answer to that question. When striving for equally good sensitivity and specificity, HI 6 performed the best with a threshold for identifying relevant emphysema heterogeneity in terms of ELVR treatment of ~9.47%. This is a notable result as there seems to be a need for such a cutoff value given that even very recent studies are still referring to the somewhat arbitrary definition of heterogeneous emphysema based on visual analysis as known from the National Emphysema Treatment Trial published in 2001.Citation11,Citation33,Citation34 It needs to be emphasized, though, that while these cutoff values give a good first orientation, further studies are needed to validate and adjust the exact cutoff value as a patient population of 50 is still too small for generalization.

Although in accordance with the recently published paper from Thomsen et al,Citation12 the fact that none of the HIs showed a statistically significant discriminatory capacity between clinically successful and unsuccessful treatment assessed with the 6MWT, the SGRQ or the RV reduction might also be due to the small population size. A bigger study is needed to validate this result.

Subgroup analysis of the patient population revealed that in patients with predominantly lower lobe emphysema and lower lobe treatment, none of the HIs had a statistically significant discriminatory capacity between clinically successful and unsuccessful treatment assessed by FEV1 improvement, whereas in patients with predominantly upper lobe emphysema and upper lobe treatment, HI 3, HI 4, HI 5, and HI 6 showed a statistically significant and rather good discriminatory capacity. This suggests that emphysema heterogeneity might indeed only be of importance when dealing with upper lobe predominant emphysema and upper lobe treatment.

Limitations of the study

Our study has several limitations, notably its retrospective design and the aforementioned patient population size of only 50, which constitutes a major limitation. For this reason, this study can only serve as a preliminary study and further studies are needed to validate the results.

Furthermore, there are factors other than the emphysema heterogeneity that affect the outcome of ELVR such as collateral ventilation, lobar perfusion, and air trapping. However, since these other factors affect all differently defined HIs in the ROC analysis equally, we are convinced that our results remain valid. The fact that there are other factors that affect FEV1 improvement after ELVR might, in turn, explain the overall only fair discriminatory capacity of the HIs. It must be emphasized, though, that these other factors mentioned previously must also be considered when evaluating a patient for lobar lung volume reduction therapy.

Another limitation of the study is the fact that the results and conclusion are based on the analysis using FEV1 as the outcome parameter and somewhat neglected the other important output parameters such as change in 6MWT test or quality of life.Citation35 Having said that, though, FEV1 has been recognized as an objective index of airflow obstruction by the COPD research community and regulatory agencies.Citation36

Conclusion

Based on the ROC analysis of this study, we recommend determining the HI of the lobe in question for ELVR by subtracting the emphysema score of the lung without the TL from the emphysema score of the TL, or alternatively, by subtracting the emphysema score of the INTL from the emphysema score of the TL, disregarding the middle lobe. The impact of interlobar emphysema heterogeneity seems to be of greater importance in patients with upper lobe predominant emphysema and upper lobe treatment than in patients with lower lobe predominant emphysema and lower lobe treatment.

Acknowledgments

D Theilig is a participant in the Charité Junior Clinical Scientist Program and V Schreiter is a participant in the Charité Clinical Scientist Program funded by Charité – Universitätsmedizin Berlin and the Berlin Institute of Health. The authors thank Dominik Herzog and Christian Thomsen for data collection and Bettina Herwig for language editing.

Supplementary materials

Table S1 ROC curve analysis of all patients (n=62) to determine the predictive accuracy of the different volume-weighted HIs (HI * targeted lobe volume) with respect to FEV1 increased after ELVR assuming an increase in FEV1 of 100 mL to indicate MCID

Table S2 Definitions of the additional HIs calculated from the TAR

Table S3 ROC curve analysis of all patients (n=62) to determine the predictive accuracy of HIs calculated from the TAR with respect to FEV1 change after ELVR assuming an increase of FEV1 of 100 mL to indicate MCID

Table S4 ROC curve analysis of all patients (n=62) to determine the predictive accuracy of the different HIs with respect to FEV1 improvement after ELVR assuming an increase in FEV1 of 100 mL to indicate MCID

Table S5 ROC curve analysis of all patients with available 6MWT results (n=44) to determine the predictive accuracy of the different HIs with respect to 6MWT improvement after ELVR, assuming an increase in 6MWT of 26 minutes to indicate MCID

Table S6 ROC curve analysis of all patients with available SGRQ test results (n=47) to determine the predictive accuracy of the different HIs with respect to SGRQ improvement after ELVR, assuming an increase in SGRQ of 4 units to indicate MCID

Table S7 ROC curve analysis of all patients (n=62) to determine the predictive accuracy of the different HIs with respect to RV reduction after ELVR, assuming a decrease in RV of 0.31 L to indicate MCID

References

  • JonesPWBeehKMChapmanKRDecramerMMahlerDAWedzichaJAMinimal clinically important differences in pharmacological trialsAm J Respir Crit Care Med2014189325025524383418
  • BandyopadhyaySHenneEGuptaASegmental approach to lung volume reduction therapy for emphysema patientsRespiration2015891768125500669

Disclosure

Dr Ralf-Harto Hubner has received lecture fees and devices from Pulmonx, the company producing the one-way valves. The authors report no other conflicts of interest in this work.

References

  • SciurbaFCErnstAHerthFJA randomized study of endobronchial valves for advanced emphysemaN Engl J Med2010363131233124420860505
  • DaveyCZoumotZJordanSBronchoscopic lung volume reduction with endobronchial valves for patients with heterogeneous emphysema and intact interlobar fissures (the BeLieVeR-HIFi study): a randomised controlled trialLancet201538699981066107326116485
  • ShahPLHerthFJCurrent status of bronchoscopic lung volume reduction with endobronchial valvesThorax201469328028624008689
  • ParkTSHongYLeeJSEfficacy of bronchoscopic lung volume reduction by endobronchial valves in patients with heterogeneous emphysema: report on the first Asian casesJ Korean Med Sci201429101404141025368495
  • ParkTSHongYLeeJSBronchoscopic lung volume reduction by endobronchial valve in advanced emphysema: the first Asian reportInt J Chron Obstruct Pulmon Dis2015101501151126251590
  • KoegelenbergCFTheronJBruwerJWEndoscopic lung volume reduction in severe emphysemaS Afr Med J2015105972172326428965
  • ValipourABurghuberOCAn update on the efficacy of endobronchial valve therapy in the management of hyperinflation in patients with chronic obstructive pulmonary diseaseTher Adv Respir Dis20159629430126294417
  • KloosterKten HackenNHHartmanJEKerstjensHAvan RikxoortEMSlebosDJEndobronchial valves for emphysema without interlobar collateral ventilationN Engl J Med2015373242325233526650153
  • GompelmannDEberhardtRHerthFJInterventional pulmonology procedures: an updatePanminerva Med201355212112923676954
  • GompelmannDSarmandNHerthFJInterventional pulmonology in chronic obstructive pulmonary diseaseCurr Opin Pulm Med201723326126828221172
  • DaveyCZoumotZJordanSBronchoscopic lung volume reduction with endobronchial valves for patients with heterogeneous emphysema and intact interlobar fissures (the BeLieVeR-HIFi trial): study design and rationaleThorax201570328829024664535
  • ThomsenCTheiligDHerzogDLung perfusion and emphysema distribution affect the outcome of endobronchial valve therapyInt J Chron Obstruct Pulmon Dis2016111245125927354783
  • HerthFJNoppenMValipourAEfficacy predictors of lung volume reduction with Zephyr valves in a European cohortEur Respir J20123961334134222282552
  • ValipourAShahPLGesierichWPatterns of emphysema heterogeneityRespiration201590540241126430783
  • SchuhmannMRaffyPYinYComputed tomography predictors of response to endobronchial valve lung reduction treatment. Comparison with ChartisAm J Respir Crit Care Med2015191776777425635349
  • GompelmannDEberhardtRSlebosDJDiagnostic performance comparison of the Chartis System and high-resolution computerized tomography fissure analysis for planning endoscopic lung volume reductionRespirology201419452453024612306
  • WanIYTomaTPGeddesDMBronchoscopic lung volume reduction for end-stage emphysema: report on the first 98 patientsChest2006129351852616537847
  • HerthFJEberhardtRGompelmannDRadiological and clinical outcomes of using Chartis to plan endobronchial valve treatmentEur Respir J201341230230822556025
  • KuhnigkJMDickenVZidowitzSInformatics in radiology (infoRAD): new tools for computer assistance in thoracic CT. Part 1. Functional analysis of lungs, lung lobes, and bronchopulmonary segmentsRadiographics200525252553615798068
  • GevenoisPADe VuystPde MaertelaerVComparison of computed density and microscopic morphometry in pulmonary emphysemaAm J Respir Crit Care Med199615411871928680679
  • WangZGuSLeaderJKOptimal threshold in CT quantification of emphysemaEur Radiol201323497598423111815
  • LynchDAAl-QaisiMAQuantitative computed tomography in chronic obstructive pulmonary diseaseJ Thorac Imaging201328528429023748651
  • MatsuoKIwanoSOkadaTKoikeWNaganawaS3D-CT lung volumetry using multidetector row computed tomography: pulmonary function of each anatomic lobeJ Thorac Imaging201227316417021873909
  • ValipourAHerthFJEberhardtRDesign of the randomized, controlled sequential staged treatment of emphysema with upper lobe predominance (STEP-UP) studyBMC Pulm Med20141419025467378
  • BandyopadhyaySHenneEGuptaASegmental approach to lung volume reduction therapy for emphysema patientsRespiration2015891768125500669
  • HerthFJValipourAShahPLSegmental volume reduction using thermal vapour ablation in patients with severe emphysema: 6-month results of the multicentre, parallel-group, open-label, randomised controlled STEP-UP trialLancet Respir Med20164318519326899390
  • ParkSHGooJMJoCHReceiver operating characteristic (ROC) curve: practical review for radiologistsKorean J Radiol200451111815064554
  • DonohueJFMinimal clinically important differences in COPD lung functionCOPD20052111112417136971
  • JonesPWBeehKMChapmanKRDecramerMMahlerDAWedzichaJAMinimal clinically important differences in pharmacological trialsAm J Respir Crit Care Med2014189325025524383418
  • CazzolaMMacNeeWMartinezFJRabeKFOutcomes for COPD pharmacological trials: from lung function to biomarkersRev Port Pneumol200814457958325967077
  • Hajian-TilakiKReceiver Operating Characteristic (ROC) curve analysis for medical diagnostic test evaluationCaspian J Intern Med20134262763524009950
  • FiorelliAPetrilloMVicidominiGQuantitative assessment of emphysematous parenchyma using multidetector-row computed tomography in patients scheduled for endobronchial treatment with one-way valvesdaggerInteract Cardiovasc Thorac Surg201419224625524821017
  • BoutouAKZoumotZNairAThe impact of homogeneous versus heterogeneous emphysema on dynamic hyperinflation in patients with severe COPD assessed for lung volume reductionCOPD201512659860526398112
  • National Emphysema Treatment Trial Research GroupFishmanAFesslerHMartinezFPatients at high risk of death after lung-volume-reduction surgeryN Engl J Med2001345151075108311596586
  • VestboJHurdSSAgustiAGGlobal strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: GOLD executive summaryAm J Respir Crit Care Med2013187434736522878278
  • CPMPPoints to consider on clinical investigation od medicinal products in the chronic treatment of patients with chronic obstructive pulmonary disease (COPD)European Agency for the Evaluation of Medical Products1999London CPMP/EWP/562/598