104
Views
6
CrossRef citations to date
0
Altmetric
Original Research

The six-minute stepper test is related to muscle strength but cannot substitute for the one repetition maximum to prescribe strength training in patients with COPD

, , , , , , , , , & show all
Pages 767-774 | Published online: 29 Mar 2019

Abstract

Purpose

There are many barriers to pulmonary rehabilitation, including a limited access to evaluation centers. To cope with these difficulties, field tests are often used to prescribe endurance training. As field tests are related to muscle strength, they could also be used to prescribe strength training and increase the access to pulmonary rehabilitation in rural area. However, their validity for this purpose has never been studied.

Patients and methods

The relationship between the 6-minute stepper test (6MST), 6-minute walk test, maximal workload achieved during cardiopulmonary exercise testing (Wpeak), and one repetition maximum (1RM) was assessed in 35 patients with COPD through a retrospective chart review to derive predictive equation of the 1RM from these tests. The effectiveness of these equations to prescribe strength training at 70% of the 1RM was assessed in an independent cross-validation group of 34 patients with COPD.

Results

There was a moderate relationship between the 6MST, Wpeak and the 1RM (r=0.44 and r=0.41, respectively, both P≤0.01). Whatever the test, the prescription of strength training using the estimated 1RM compared with the measured 1RM resulted in a mean absolute difference and a mean bias of about 30 kg.

Conclusion

The use of the 6MST and Wpeak for the prescription of strength training would result in a clinically not acceptable error. Therefore, they should not be used as a substitute for the 1RM to prescribe strength training.

Introduction

COPD is a worldwide cause of morbidity and mortality with a gradually increasing prevalence.Citation1,Citation2 Pulmonary rehabilitation is widely recommended to cope with the systemic effects of COPDCitation3Citation5 and effectively improves exercise capacity and quality of life.Citation6 Unfortunately, <1% of patients who would benefit from it can access these programs, mainly due to the lack of rehabilitation and assessment centers, and their location in urban area. Pulmonary rehabilitation usually includes both endurance and strength training.Citation3Citation5 Thus, although the optimal assessment for endurance training prescription should include cardiopulmonary exercise testing (CPET),Citation3 it is often not available for a large number of patients. Alternatively, the one-repetition maximum (1RMw, which is the weight that can be lifted, pushed, or pulled only once without compensation) is frequently used in clinical practice for assessing and prescribing muscle strength.Citation4,Citation9Citation11 However, it requires trained personnel and a learning period before the measurement to increase reliability and reduce bias, and is therefore time consuming. Moreover, it is possibly traumatic in several pathologies with comorbidities such as COPD (eg, bone, ligament, and muscular stress or injury).Citation10 Therefore, it can be difficult to obtain due to pain or muscle fatigue even though sub-maximal strength training (about 70% of 1RM as usually prescribed)Citation4,Citation12Citation15 will be possible, highlighting a need for an easier and faster tool to assess and prescribe strength training.

Field tests have been proposed to replace CPET for the prescription of endurance training.Citation16Citation21 For example, the 6-minute stepper test (6MST), which is easier to perform than the widely used 6-minute walk test (6MWT) and does not need a 30 m long corridor,Citation22 has been validated to assess exercise capacity in patients with COPDCitation23Citation25 and has recently been considered for endurance training prescription.Citation17,Citation20,Citation21 Although field tests are often related to quadriceps muscular strength,Citation26Citation28 their use for strength training prescription has not been studied.

The aim of this study was to assess whether the 6MST could be used to prescribe strength training in patients with COPD accurately. The usability of the maximal workload attained during the CPET (Wpeak) and the 6MWT was also studied.

Materials and methods

Study design and patient selection

Patients with COPD referred for pulmonary rehabilitation between September 2015 and October 2018 to the ADIR Association (Association d’aide à domicile des patients insuffisants respiratoires), Rouen University Hospital, France, were retrospectively studied. The study was approved by the Comité d’Ethique de la Recherche non-interventionnelle from Rouen University Hospital (E2018-67). According to the French law, patients were informed in writing that their data could be used for future research purposes and formal consent to retrospectively review their medical records was not required. None of these patients used this right of refusal. Patient data confidentiality was maintained and the protocol was performed in compliance with the Declaration of Helsinki.

Inclusion criteria

Patients with a clinical diagnosis of COPD (FEV1/FVC ratio <0.70) were included. The severity of airflow limitation was assessed according to the GOLD classification.Citation29 They had to be 18 years old; stable (free from acute exacerbation in the previous month); and have performed both the 6MST and the quadriceps 1RM assessment during the first session of their pulmonary rehabilitation. They also had to weigh 90 kg or less (maximum weight supported by the stepper).

Exclusion criteria

Patients for whom the quadriceps 1RM exceeded 120 kg on one limb (leg press’s limit) and those for whom the 1RM was not maximal due to musculoskeletal limitation were excluded.

Data extraction

Data regarding demographic features, comorbidities, pulmonary function, exercise capacity (6MST, Wpeak, and 6MWT), quadriceps 1RM, and use of long-term oxygen or home mechanical ventilation were extracted though a retrospective chart review.

Assessment

1RM

Quadriceps 1RM was performed on a pulley press (Legpress; Design Corporel, Salomé, France). Patients were in a semi-sitting position, back against the backside with a 90° knee and hip flexion.Citation30 They were vigorously encouraged to extend both of their knees simultaneously. Patients had to put their hands on the side handles of the press or to keep them on their stomach. In the case of values exceeding 120 kg divided over the two lower limbs, the press reached its limit. Therefore, the search for the 1RM value proceeded as before: with a progressive rise in the weight if the lift was successful, however it was now realized on the one leg. Therefore, patients were told to put the foot of the exercising lower limb in the middle of the steel plate and the other lower limb (not exercising) on the sliding rail in order to avoid any compensation. The sum of both lower limbs was considered as quadriceps 1RM.

6MST

Patients performed two 6MSTs (Athlitec; GoSport, Sassenage, France). The second test began when the heart rate (HR), and the transcutaneous oxygen saturation (SpO2) values returned to baseline values after a rest period of at least 20 minutes. The performance of the second test was recorded for analysis.Citation20 Standardized instructions were based on the American Thoracic Society guidelines for the 6MST as previously described.Citation23

CPET

CPET was performed on an electromagnetic braked ergometer (Ergoselect 200; Ergoline, Bitz, Germany). Following a 3 minutes warm-up period, incremental ramp exercise (5–20 W/min) was applied up to exhaustion. A pneumotachograph and a gas analyzer (Ergocard; Medisoft, Louvain, Belgium) were used to measure gases (oxygen consumption [VO2] and carbon dioxide production [VCO2] breath by breath) through a face mask (Hans Rudolph, Inc., Kansas City, MO, USA). The last ramp maintained before exhaustion or the workload achieved at VO2peak was considered as Wpeak.

6MWT

The 6MWT was performed according to the American Thoracic Society guidelines along a 30 m corridor.Citation22 The test was carried out twice and the longest distance was used in the analysis.

Outcome

The evaluation of the reliability of using the 6MST to prescribe the strength training involved four steps. First, the relation between the number of steps performed during the 6MST and the quadriceps 1RM was assessed in the first group of subjects (prediction group) with COPD.Citation31 Next, in the case of a significant relationship, a linear regression was performed to derive a predictive equation of the 1RM from the 6MST. Third, in a second and independent cross-validation group of subjects with COPD, the quadriceps 1RM was estimated from the predictive equation. The last step was to assess the error that would be associated with using estimated 1RM to prescribe strength training in a clinical situation (70% of the 1RM).Citation4,Citation12Citation15 The same method was applied for both Wpeak and the 6MST.

Statistical analysis

The normality of the distribution was assessed using the Kolmogorov–Smirnov test. Categorical data were expressed as counts (%) and continuous data were expressed as mean (SD) or median (25th–75th percentile) according to the distribution. Comparison between the baseline characteristics of both groups was assessed with Fisher’s test (for proportion) and independent Student’s t-test or Mann–Whitney test, depending on the distribution.

Determination of the predictive equation in the prediction group

The relationship between the 6MST, Wpeak, 6MWT, and 1RM was assessed using Pearson or Spearman correlation test. Single linear regressions were performed when appropriate. Since several data were not normally distributed, they were normalized using a log-transformation. A predictive equation using linear regression was then derived.

Validation of the predictive equation in cross-validation group

The comparison of the prescribed workload (70% 1RM) between the measured 1RM and the estimated 1RM was assessed using the mean absolute difference (MAD) between both prescription and a Bland–Altman analysis. As the increment of the leg press is done by 5 kg, the prescriptions were a priori considered as clinically equivalent if the limits of agreements (upper and lower bounds) were <5 kg. A P-value <0.05 was deemed significant. Prism 5 software was used for analyses.

Results

Patients

Among the 356 patients referred for pulmonary rehabilitation over the study period, 78 met the inclusion criteria. Two were excluded because the quadriceps 1RM exceeded 120 kg on one limb. A further seven were excluded from the analysis because the 1RM was limited due to musculoskeletal impairment (). Finally, 69 patients were included for the analysis. The first 35 patients were selected to derive the predictive equations,Citation31 while the 34 subsequent patients were used to assess the validity of the equations to prescribe strength training (cross-validation group). The patients’ characteristics of both groups are shown in . Overall, the mean age was 60 (SD 10) years, 42% were women, and 30% were long-term oxygen users. They had a severe obstruction (median FEV1%: 38 [IQR 30–58]) and impaired exercise capacity (mean VO2peak: 14 [SD 4] mL/kg/min). There were significantly more females in the cross-validation group (56% compared with 29%, P=0.03).

Table 1 Characteristics of the patients

Figure 1 Flow of patients through the study.

Abbreviation: 1RM, one repetition maximum test.
Figure 1 Flow of patients through the study.

Relationship with the 1RM (prediction group)

There was a significant relationship between the 6MST, Wpeak and log1RM (r=0.44, P<0.01 and r=0.41, P=0.01, respectively, ). The 6MWT was only available for 13 patients and there was no significant relationship with log1RM.

Figure 2 Linear relationship and predictive equations between (A) the 6-minute stepper test, (B) the maximal workload achieved during the cardiopulmonary exercise testing (Wpeak) and the one repetition maximum (1RM).

Figure 2 Linear relationship and predictive equations between (A) the 6-minute stepper test, (B) the maximal workload achieved during the cardiopulmonary exercise testing (Wpeak) and the one repetition maximum (1RM).

Predictive equations (prediction group)

Log1RM could be predicted, respectively, for the 6MST and Wpeak by the following equations ():

Log1RM=0.0009379×6MST(steps)+1.713;
Log1RM=0.00223×Wpeak(W)+1.757.

As the 6MWT was not correlated with log1RM, no predictive equation was derived.

Validation of the predictive equations (cross-validation group)

The MAD between the prescriptions of strength training at a value of 70% of the 1RM using the actually measured and the predicted 1RM was 31 (SD 30) kg for the 6MST and 29 (SD 28) kg for Wpeak. The limits of agreement and corresponding Bland–Altman plots are presented for the 6MST in and for Wpeak in .

Figure 3 Bland–Altman plots for the prescription of strength training using the predictive equations derived from the 6-minute stepper test (A) and Wpeak (B). The point-to-point difference between the two prescriptions (actually measured minus estimated) is plotted against the mean of the two prescriptions. 95% CI limits of agreement (lower and upper bounds) were −36 to 92 for the 6MST and −31 to 85 for Wpeak.

Abbreviations: 6MST, 6-minute stepper test; Wpeak, the maximal workload achieved during the cardiopulmonary exercise testing.
Figure 3 Bland–Altman plots for the prescription of strength training using the predictive equations derived from the 6-minute stepper test (A) and Wpeak (B). The point-to-point difference between the two prescriptions (actually measured minus estimated) is plotted against the mean of the two prescriptions. 95% CI limits of agreement (lower and upper bounds) were −36 to 92 for the 6MST and −31 to 85 for Wpeak.

Discussion

The main finding of this study was that there was a significant relationship between exercise capacity assessment tests used to prescribe endurance training and the 1RM. However, this relationship was only moderate, and the use of predictive equations to estimate the 1RM from these tests to prescribe strength training would result in an inacceptable error for clinical practice (about 30 kg). As can be seen in , the amount of error seems to increase with the increase of the 1RM.

The assessment of the 1RM is the gold standard for strength training prescription.Citation4,Citation9 However, it could be compromised in pathological condition and is time consuming.Citation11 Although the measurement of the 1RM was found to be feasible in a small cohort of patients with COPD,Citation30 it might be limited by comorbidities. In the present study, about 10% of the patients were excluded due to pain (due to muscu-loskeletal comorbidities) during the measurement, which led to an underestimation of the 1RM even though strength training at 70% 1RM would have been possible. Therefore, indirect measurement of the 1RM to allow effective training seems necessary.

There are many barriers to pulmonary rehabilitation, including a limited access to evaluation centers and CPET.Citation7,Citation8 To cope with these difficulties, field tests are often used to prescribe endurance training.Citation16Citation21 As several field tests are related to muscle strength,Citation26,Citation27 as well as the 6MST in the present study, the idea to use the same test to prescribe both endurance and strength training looks attractive at the first glance to increase the access to pulmonary rehabilitation in rural area. Surprisingly, there was no relationship between the 6MWT and the 1RM. Conversely, Rausch-Osthoff et al found a significant moderate correlation between the quadriceps strength and the distance covered during 6MWT.Citation27 This difference was likely due to the few numbers of 6MWT records available in subjects from the prediction group because the study was not designed for this outcome.

However, the present results suggest that the use of both the 6MST and CPET to prescribe strength training would result in a significant error, refuting their use for clinical prac-tice. In healthy subjects, several authors suggested the use of anthropologic data such as age, gender, height, weight, lean body mass, and thigh girth.Citation10 Adding these characteristics in a multivariate analysis in a larger cohort of subjects with COPD may help to refine the present equations and improve their accuracy to prescribe strength training. Alternatively, the prediction of the 1RM from the perceived exertion (BORG scale)Citation11,Citation32 has been proposed for healthy subjects but remains to be evaluated in subjects with COPD.

There are several explanations for the inaccuracy that occurred when using the estimated 1RM to prescribe strength training.

First, the relationship between Wpeak, 6MST and the 1RM was only moderate (r=0.40). Since cycling, stepping, and strength training provide substantially different effort and metabolic load,Citation33Citation36 several parameters such as ventilatory pattern, hematosis, cardiovascular adaptation, muscle mass involved, weight, and balance may explain this moderate correlation. Moreover, compared with endurance capacity, muscular strength is relatively well preserved in patients with COPD due to a shift toward an increased proportion of fast twitch muscular fiber (type II), which are specifically recruited during strength training and the 1RM assessment.Citation37 Conversely, Wpeak and the 6MST do not only reflect the type II fibers activity but also include the recruitment of the slow twitch fibers (type I), as suggested by the relationship between the 6MST and VO2peak.Citation25 This may also contribute to explain the systematic bias observed in the Bland and Altman analysis () showing that the error increases proportionally to the 1RM (eg, the least disabled patients had a preserved type II fibers and a high 1RM but likely an already present alteration of the type I fibers and therefore a relatively low performance on the 6MST). Additionally, the nature of the 1RM assessment and strength training allows the patients to rest between repetitions while the exercise is continuous during cycling or stepping, causing more dyspnea and fatigue in the latter.Citation36 This likely allowed a more important recruitment of muscular fibers during the assessment of the 1RM.

Secondly, there were significantly more females in the cross-validation group. This might have introduced some bias due to gender, since it has an impact on perceived dyspneaCitation38 and muscular type fibers.Citation39 However, the latter is reported inconsistently,Citation40 and there are no gender differences in cardiopulmonary responses during the 1RM testing.Citation30 Therefore, it is unlikely that these factors alone account for the amount of error observed between both prescriptions.

Limits and strength

First, a bias cannot be excluded due to the retrospective design of the study. However, this reflected daily clinical practice providing external validity of the results. Moreover, statistical tests were limited to those reported in order to avoid any type one error due to multiple comparison frequently encountered in retrospective studies. Secondly, the population was relatively selected (eg, no major balance impairment and weight under 90 kg for the 6MST). This cannot be neglected considering that a considerable number of patients with COPD are overweightCitation41,Citation42 and present balance disorders.Citation43

The most important strength of this study was the evaluation of the predictive equation in an independent cross-validation group which has invalidated the use of both tests for the prescription of strength training.

Conclusion

Wpeak and the 6MST are both related to the quadriceps strength (1RM). Although the CPET and the 6MST could be used to prescribe endurance training in patients with COPD, their use for the prescription of strength training would result in a clinically nonacceptable error. Therefore, they should not be used for this purpose and both the 1RM and the voluntary maximal contraction remain the recommended methods to assess muscle strength in clinical practice. Further prospective studies are needed to confirm these results and explore the potential usefulness of the 6MWT for this purpose.

Ethics approval

This study was approved by the Comité d’Ethique de la Recherche non-interventionnelle from Rouen University Hospital (E2018-67).

Data sharing statement

Deidentified participant data published in the manuscript will be shared to searchers performing a meta-analysis on request. Data will be available after publication.

Acknowledgments

We thank ADIR Assistance, Asten group, Gwenaëlle Leteur-tre for support during data collection, and Johanna Robertson for revision of the English text. This work was supported by ADIR Association.

Disclosure

Dr MP reports grants from B&D Electromedical, personal fees from ResMed and Philips Respironics, grants and non-financial support from Fisher & Paykel, nonfinancial support from MSD, nonfinancial support from Asten, and grants from ADIR Association, outside the submitted work. The other authors report no conflicts of interest in this work.

References

  • LozanoRNaghaviMForemanKGlobal and regional mortality from 235 causes of death for 20 age groups in 1990 and 2010: a systematic analysis for the global burden of Disease Study 2010The Lancet2012380985920952128
  • KhakbanASinDDFitzgeraldJMThe projected epidemic of chronic obstructive pulmonary disease hospitalizations over the next 15 years. A population-based perspectiveAm J Respir Crit Care Med2017195328729127626508
  • Société de Pneumologie de Langue FrançaiseRecommandation pour la Pratique Clinique : prise en charge de la BPCORev Mal Respir201027522548 French20569889
  • SpruitMASinghSJGarveyCAn official American Thoracic Society/European Respiratory Society statement: key concepts and advances in pulmonary rehabilitationAm J Respir Crit Care Med20131888e13e6424127811
  • BoltonCEBevan-SmithEFBlakeyJDBritish Thoracic Society guideline on pulmonary rehabilitation in adultsThorax201368Suppl 2ii1ii3023880483
  • MccarthyBCaseyDDevaneDPulmonary rehabilitation for chronic obstructive pulmonary diseaseCochrane Database Syst Rev201531CD003793
  • BrooksDSottanaRBellBCharacterization of pulmonary rehabilitation programs in Canada in 2005Can Respir J2007142879217372635
  • SticklandMKJourdainTWongEYLRodgersWMJendzjowskyNGMacdonaldGFUsing telehealth technology to deliver pulmonary rehabilitation to patients with chronic obstructive pulmonary diseaseCan Respir J201118421622022059179
  • LevingerIGoodmanCHareDLJerumsGToiaDSeligSThe reliability of the 1RM strength test for untrained middle-aged individualsJ Sci Med Sport200912231031618078784
  • ReynoldsJMGordonTJRobergsRAPrediction of one repetition maximum strength from multiple repetition maximum testing and anthropometryJ Strength Cond Res200620358459216937972
  • EstonREvansHJThe validity of submaximal ratings of perceived exertion to predict one repetition maximumJ Sports Sci Med20098456757324149599
  • SillenMJFranssenFMDelbressineJMVaesAWWoutersEFSpruitMAEfficacy of lower-limb muscle training modalities in severely dyspnoeic individuals with COPD and quadriceps muscle weakness: results from the DICES trialThorax201469652553124399630
  • Zambom-FerraresiFCebolleroPGorostiagaEMEffects of combined resistance and endurance training versus resistance training alone on strength, exercise capacity, and quality of life in patients with COPDJ Cardiopulm Rehabil Prev201535644645326252342
  • OrtegaFToralJCejudoPComparison of effects of strength and endurance training in patients with chronic obstructive pulmonary diseaseAm J Respir Crit Care Med2002166566967412204863
  • CoveyMKCollinsEGReynertsonSIDillingDFResistance training as a preconditioning strategy for enhancing aerobic exercise training outcomes in COPDRespir Med201410881141115224958605
  • BonnetPPoulainMPalombaBUtilisation du test de marche de 6 minutes pour individualiser un réentrainement l’effort chez le bronchopneumopathe chronique obstructif (BPCO). [Using the 6-minute walk test to individualize retraining effort in Chronic Obstructive Pulmonary Disease (COPD)]Revue des maladies respiratoires2001182S6362S64 French
  • FabreCChéhèreBBartFMucciPWallaertBGrosboisJMRelationships between heart rate target determined in different exercise testing in COPD patients to prescribed with individualized exercise trainingInt J Chron Obstruct Pulmon Dis2017121483148928553100
  • dal CorsoSde CamargoAAIzbickiMMalagutiCNeryLEA symptom-limited incremental step test determines maximum physiological responses in patients with chronic obstructive pulmonary diseaseRespir Med2013107121993199923863809
  • ZainuldinRMackeyMGAlisonJAPrescription of walking exercise intensity from the 6-minute walk test in people with chronic obstructive pulmonary diseaseJ Cardiopulm Rehabil Prev2015351656924983708
  • BonnevieTGravierF-ELeboullengerMSix-minute Stepper test to set pulmonary rehabilitation intensity in patients with COPD – a retrospective studyCOPD201714329329728388274
  • BonnevieTGravierF-ECuvelierADebeaumontDSix-Minute Stepper test to set pulmonary rehabilitation intensity in patients with COPDCOPD2018151919229319356
  • ATS Committee on Proficiency Standards for Clinical Pulmonary Function LaboratoriesATS statement: guidelines for the six-minute walk testAm J Respir Crit Care Med2002166111111712091180
  • BorelBFabreCSaisonSBartFGrosboisJMAn original field evaluation test for chronic obstructive pulmonary disease population: the six-minute stepper testClin Rehabil2010241829320053721
  • CoquartJBLemaîtreFCastresISaisonSBartFGrosboisJ-MReproducibility and sensitivity of the 6-minute Stepper test in patients with COPDCOPD201512553353825526322
  • GrosboisJMRiquierCChehereBSix-minute stepper test: a valid clinical exercise tolerance test for COPD patientsInt J Chron Obstruct Pulmon Dis20161165766327099483
  • ZaniniAAielloMCherubinoFThe one repetition maximum test and the sit-to-stand test in the assessment of a specific pulmonary rehabilitation program on peripheral muscle strength in COPD patientsInt J Chron Obstruct Pulmon Dis2015102423243026648705
  • Rausch-OsthoffAKKohlerMSieviNAClarenbachCFvan GestelAJAssociation between peripheral muscle strength, exercise performance, and physical activity in daily life in patients with chronic obstructive pulmonary diseaseMultidiscip Respir Med2014913725013723
  • GosselinkRTroostersTDecramerMPeripheral muscle weakness contributes to exercise limitation in COPDAm J Respir Crit Care Med199615339769808630582
  • Global Initiative for Chronic Obstructive Lung DiseaseGlobal strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease2018 Available from: https://goldcopd.org/gold-reports/Accessed March 22, 2019
  • KaelinMESwankAMAdamsKJBarnardKLBerningJMGreenACardiopulmonary responses, muscle soreness, and injury during the one repetition maximum assessment in pulmonary rehabilitation patientsJ Cardiopulm Rehabil199919636637210609187
  • Wilson van VoorhisCRMorganBLUnderstanding power and rules of thumb for determining sample sizesTutor Quant Methods Psychol2007324350
  • BorgGAVPsychophysical bases of perceived exertionMedicine, Science in Sports & Exercise1982145377381
  • MahlerDAGiffordAHWatermanLAWardJMachalaSBairdJCMechanism of greater oxygen desaturation during walking compared with cycling in patients with COPDChest2011140235135821273296
  • MathurRSRevillSMVaraDDWaltonRMorganMDComparison of peak oxygen consumption during cycle and treadmill exercise in severe chronic obstructive pulmonary diseaseThorax19955088298337570432
  • SinghSJMorganMDHardmanAERoweCBardsleyPAComparison of oxygen uptake during a conventional treadmill test and the shuttle walking test in chronic airflow limitationEur Respir J1994711201620207875275
  • ProbstVSTroostersTPittaFDecramerMGosselinkRCardiopulmonary stress during exercise training in patients with COPDEur Respir J20062761110111816540501
  • CouillardAPrefautCFrom muscle disuse to myopathy in COPD: potential contribution of oxidative stressEur Respir J200526470371916204604
  • GuenetteJAJensenDWebbKAOfirDRaghavanNO’DonnellDESex differences in exertional dyspnea in patients with mild COPD: physiological mechanismsRespir Physiol Neurobiol2011177321822721524719
  • AusínPMartínez-LlorensJSabaté-BrescoMCasadevallCBarreiroEGeaJSex differences in function and structure of the quadriceps muscle in chronic obstructive pulmonary disease patientsChron Respir Dis201714212713927923983
  • TorresSHMontes de OcaMLoebEMataAHernándezNGender and skeletal muscle characteristics in subjects with chronic obstructive pulmonary diseaseRespir Med20111051889420580542
  • EisnerMDBlancPDSidneySBody composition and functional limitation in COPDRespir Res200781717261190
  • SteutenLMCreutzbergECVrijhoefHJWoutersEFCOPD as a multicomponent disease: inventory of dyspnoea, underweight, obesity and fat free mass depletion in primary carePrim Care Respir J2006152849116701766
  • PortoEFCastroAASchmidtVGPostural control in chronic obstructive pulmonary disease: a systematic reviewInt J Chron Obstruct Pulmon Dis2015101233123926170652