Adherence ability of Staphylococcus epidermidis on prosthetic biomaterials: an in vitro study

, , , , &
Pages 3955-3961 | Published online: 14 Oct 2013

Abstract

Bacterial adhesion to the surface of biomaterials is an essential step in the pathogenesis of implant-related infections. In this in vitro research, we evaluated the ability of Staphylococcus epidermidis to adhere to the surface of solid biomaterials, including oxidized zirconium-niobium alloy (Oxinium), cobalt-chromium-molybdenum alloy, titanium alloy, commercially pure titanium, and stainless steel, and performed a biomaterial-to-biomaterial comparison. The test specimens were physically analyzed to quantitatively determine the viable adherent density of the S. epidermidis strain RP62A (American Type Culture Collection [ATCC] 35984). Field emission scanning electron microscope and laser microscope examination revealed a featureless, smooth surface in all specimens (average roughness <10 nm). The amounts of S. epidermidis that adhered to the biomaterial were significantly lower for Oxinium and the cobalt-chromium-molybdenum alloy than for commercially pure titanium. These results suggest that Oxinium and cobalt-chromium-molybdenum alloy are less susceptible to bacterial adherence and are less inclined to infection than other materials of a similar degree of smoothness.

View correction statement:
Adherence ability of Staphylococcus epidermidis on prosthetic biomaterials: an in vitro study [Corrigendum]

Introduction

A wide variety of solid, artificial biomaterials are implanted in the human body for a range of different purposes and have made a significant contribution to medical progress. In the field of orthopedic surgery, biomaterials with particular mechanical characteristics are now being used more frequently and for a wide range of purposes, including prostheses and trauma plates/nails. However, one disadvantage with these biomaterials is that they provide a suitable site for bacterial colonization in implant-related infection.Citation1Citation3 When bacteria adhere to and proliferate on the biomaterial surface, they secrete mucopolysaccharides and form a biofilm. The biofilm that envelopes the bacteria protects them from the immune system and antibacterial agents, so implant-related infections are extremely difficult to treat. Although various methods of prevention have been devised, implant-related infections still occur today in 0.2%–17.3% of cases of prosthetic orthopedic surgery.Citation4Citation6 In addition to long-term antibiotic administration, many cases require surgery to remove and debride the implant and/or to implant a cement mold containing antibiotics to ameliorate the infection. Research into the problem of bacterial adhesion to biomaterials is therefore critically important from a clinical perspective.

Most implant-related infections are caused by the Staphylococcus species.Citation7Citation10Staphylococcus epidermidis, one of the most commonly isolated bacterial pathogens, is particularly capable of adhering to and aggregating on biomaterial surfaces, and it can form biofilms on many different biomaterials.Citation10,Citation11 The process of bacterial adherence is generally thought to be governed by van der Waals interactions, such that the bacteria reach the surface of the artificial material by overcoming energy barriers, through electrostatic repulsion, and then form colonies by way of reversible/irreversible adhesion.Citation12,Citation13 Research has shown that polysaccharide intercellular adhesin (PIA) plays an important role in bacterial adhesion as well as in biofilm formation.Citation14Citation17 However, the exact mechanism of adhesion has yet to be determined because of the complex combination of numerous other factors related to the bacteria, the in vivo environment, and the artificial material involved.

The solid biomaterials used for clinical purposes are strictly regulated through standards, such as the International Organization for Standardization (ISO) and the American Society for Testing and Materials (ASTM). Biomaterials can be made of just a few kinds of standardized materials, depending on their application, including titanium, stainless steel, cobalt-chromium-molybdenum alloy (Co-Cr-Mo) and ultra-high-molecular-weight polyethylene. Oxinium is an oxidized zirconium-niobium alloy, commercialized as a new biomaterial in Japan in 2008. It is created by permeating the zirconium-niobium alloy with oxygen at a high temperature so that only a 5 μm surface layer is changed to zirconium ceramic. As a result, Oxinium has the characteristic of low abrasion on sliding surfaces, like a ceramic, and is strong like a metal. It also contains almost no toxic metals.Citation18

Steinberg et al reported differences in bacterial adhesion to two different material surfaces, titanium and titanium alloy.Citation19 Recently, there have been a number of reports on the impact on bacterial adhesion of surface roughness, wettability, and other physical properties of the actual solid materials themselves.Citation20Citation28 However, most of this research has been on dental implants, on the basis of conditions found in the mouth.Citation25Citation28 There is little research into the adhesion of S. epidermidis to other medical materials used in clinical practice, and their results were mostly inconsistent. Olson et al investigated the adhesion of PIA-producing S. epidermidis on biomaterial surfaces and reported differences between the different types of material but did not discuss the causes or mechanisms involved.Citation17 Ha et al reported a more extensive adherence ability of biofilm-forming S. epidermidis on a titanium alloy (Ti-6Al-4V) than on stainless steel and suggested this was the effect of the inherent characteristics and roughness of titanium but detailed values of roughness or wettability were not discussed.Citation29

In this in vitro study, we compared and investigated the ability of S. epidermidis to adhere to surfaces made of solid materials that are actually used in clinical practice – Oxinium, Co-Cr-Mo, titanium alloy, commercially pure titanium, and stainless steel – and that have a similar degree of smoothness, in order to eliminate any discrepancies due to the effect of surface roughness. We have found no previous research that focuses on the adherence capabilities of different biomaterials, including Oxinium.

Materials and methods

Specimen preparation

We prepared circular specimens (12 mm in diameter, 6 mm thick) from Oxinium (ASTM F2384), Co-Cr-Mo (ASTM F75, high carbon), Ti-6Al-4V (ASTM F136), commercially pure titanium (CP-Ti) (ASTM F67), and stainless steel (ASTM F138). All the specimens were obtained from Smith & Nephew Orthopaedics Inc. (Memphis, TN, USA). The five kinds of test specimens were polished using a centrifugal barrel finishing process. This process involved the use of proprietary polishing compounds (trade secrets) for Oxinium, while a polishing cloth and diamond slurry (Maruto Instrument Co. Ltd., Tokyo, Japan; 1 μm particle diameter) was used for the other four materials.

Surface analysis

Micrographs of the surface of the specimen disks were obtained using a field emission scanning electron microscope (SEM) (JSM 6610LV; JEOL Ltd, Tokyo, Japan). The micrographs were taken at two randomly chosen areas on each specimen (one in a central position and one at 1–1.5 mm in from the outer edge). The surface morphology and roughness of the specimens were measured by means of a three-dimensional (3D) measuring laser microscope (OLS4000, Shimadzu Corp, Tokyo, Japan) with a cutoff value (λc) of 80 µm at room temperature. Three readings were made of each surface on three random samples, and the average roughness (Ra) and mean roughness profile depth (Rz) were used to characterize the roughness of the specimens. The initial contact angles of the surface of each specimen to deionized water (Milli-Q®; EMD Millipore, Billerica, MA, USA) were measured by the drop method, using an automated contact angle measurement device (DSA30; Krüss GmbH, Hamburg, Germany) at room temperature. On each of four randomly selected specimens, three drops of deionized water (2 μL) were analyzed (twelve measurements in total per product), and the left and the right contact angles of each drop were averaged.

Experimental design

The S. epidermidis strain RP62A (American Type Culture Collection [ATCC]35984; American Type Culture Collection, Manassas, VA, USA) was cultured in Trypticase™ Soy Broth (TSB) (BD Biosciences, Franklin Lakes, NJ, USA) at 37°C for 6 hours to create a bacterial suspension of 7.5 × 107 colony-forming units (CFU)/mL (logarithmic growth: optical density [OD] 600=0.2; pH 7.0). In this research, we only used a PIA-producing strain that was determined by reverse transcription polymerase chain reaction (RT-PCR) to be positive for the ica-A gene.Citation30 Before the experimental procedure, all test specimens were sterilized by way of ultrasonic cleaning and steam autoclaving (121°C). Then, 2 μL of the bacterial suspension was dropped on the specimen, which was then placed at room temperature for 60 minutes. The specimens were then rinsed twice with phosphate-buffered saline (PBS) (Sigma-Aldrich Corp, St Louis, MO, USA), pH 7.0, to remove any unbound cells. The surface of three samples of each biomaterial were fixed with ethanol, stained with crystal violet, and imaged using a digital optical microscope (VHX-100; Keyence, Osaka, Japan). Other samples to be used to measure bacterial adhesion were transferred into sterile conical tubes (Falcon®; BD Biosciences, Franklin Lakes, NJ, USA) containing 5 mL of fresh TSB medium. The tubes were vortexed at full speed for 1 minute and then placed in an ultrasonic bath and sonicated for 15 minutes at 120 W, to release the attached cells from the biomaterial. After an additional vortex step, the specimen was taken out, and the bacterial separation from the surface of each specimen, on which no remaining attached bacteria were observed, was confirmed by digital optical microscope. The remaining suspensions were serially diluted with PBS and cultured at 37°C for 48 hours with a Compact Dry TC culture kit (Nissui Pharmaceutical Co, Ltd, Tokyo, Japan). The CFUs were counted to determine the number of viable adherent bacteria, and the bacterial density (CFU/mL) was calculated. The above procedure was performed twelve times for each material. As well as using uniform conditions for the bacteria, the five kinds of specimens were treated at the same time, and the experiments themselves were repeated using a uniform procedure to eliminate the effect of environmental factors.

Statistical analysis

The means and standard deviations of the topographic parameters of the specimens (n=6), contact angles (n=12), and viable adherent bacteria densities (n=12) were analyzed for the different materials using SPSS 10.0 statistical software (SPSS Inc., Chicago, IL, USA). The statistical analysis was performed using one-way analysis of variance (ANOVA), multiple comparison tests, and the Tukey–Kramer and Bonferroni–Dunn multiple comparison tests for the post hoc analysis. The value of statistical significance was set at P<0.05.

Results

Field emission SEM images of the prepared surfaces of the disks are shown in . Although there were some fine polishing microtraces and marks of diameter 10 to 200 μm homogeneously distributed over the sample, all the specimens were observed to be generally featureless, with a smooth surface topography. The numerous micropore- or coral-like structures of the Oxinium, seen at the standard detector SEM, indicated the difference in configuration between zirconium ceramic and zirconium-niobium alloy. The mean surface roughness parameters for each type of specimen are shown in . Co-Cr-Mo (mean Ra =2.3 nm) and stainless steel (mean Ra =1.4 nm) had significantly smoother surfaces than the Oxinium (mean Ra =7.5 nm), Ti-6Al-4V (mean Ra =4.8 nm), and CP-Ti (mean Ra =5.4 nm). However, all the specimens had comparatively smooth surfaces and recorded a low average roughness (Ra <10 nm). One-way ANOVA indicated significant differences in the water contact angles between the various materials. Post hoc analysis revealed the highest water contact angle was for Co-Cr-Mo, followed by stainless steel, CP-Ti, and Ti-6Al-4V Oxinium yielded the lowest water contact angle (). Digital microscopic observations revealed bacteria of an aggregated and colonized appearance (small colonies) adhering to the surface of all the specimens (). shows the results of the adhesion of S. epidermidis to the various specimens. The viable adhered cell count (×105/mL) was an average of 9.3 ± 3.0 for Oxinium, 9.1 ± 5.0 for Co-Cr-Mo, 13.5 ± 3.1 for Ti-6Al-4V, 16.7 ± 8.1 for CP-Ti, and 14.3 ± 2.9 for stainless steel. Therefore, the amounts of S. epidermidis that adhered to the Oxinium and Co-Cr-Mo specimens were significantly lower than the amounts that adhered to CP-Ti (P,0.01).

Table 1 Surface roughness

Table 2 Contact angles of deionized water (degree)

Figure 1 SEM micrographs.

Notes: The images show Oxinium (A), Co-Cr-Mo (B), Ti-6Al-4V (C), CP-Ti (D), and stainless steel (E). although a few polishing microtraces and marks were observed, all specimens had a generally featureless and smooth surface. Original magnification × 1000 (scale bar = 10 μ m).

Abbreviations: Co-Cr-Mo, cobalt-chromium-molybdenum alloy; CP-Ti, commercially pure titanium; SEM, scanning electron microscope; Ti-6Al-4V, titanium alloy.

Figure 1 SEM micrographs.Notes: The images show Oxinium (A), Co-Cr-Mo (B), Ti-6Al-4V (C), CP-Ti (D), and stainless steel (E). although a few polishing microtraces and marks were observed, all specimens had a generally featureless and smooth surface. Original magnification × 1000 (scale bar = 10 μ m).Abbreviations: Co-Cr-Mo, cobalt-chromium-molybdenum alloy; CP-Ti, commercially pure titanium; SEM, scanning electron microscope; Ti-6Al-4V, titanium alloy.

Figure 2 Digital optical micrographs.

Notes: Bacteria stained with 0.5% crystal violet were observed on the surface of: Oxinium (A), Co-Cr-Mo (B), Ti-6Al-4V (C), CP-Ti (D), and stainless steel (E). Original magnification ×450 (scale bar =100 μm).

Abbreviations: Co-Cr-Mo, cobalt-chromium-molybdenum alloy; CP-Ti, commercially pure titanium; Ti-6Al-4V, titanium alloy.

Figure 2 Digital optical micrographs.Notes: Bacteria stained with 0.5% crystal violet were observed on the surface of: Oxinium (A), Co-Cr-Mo (B), Ti-6Al-4V (C), CP-Ti (D), and stainless steel (E). Original magnification ×450 (scale bar =100 μm).Abbreviations: Co-Cr-Mo, cobalt-chromium-molybdenum alloy; CP-Ti, commercially pure titanium; Ti-6Al-4V, titanium alloy.

Figure 3 Viable adhered cell count of Staphylococcus epidermidis (×105/ml).

Notes: Mean and standard deviation are shown. **P<0.01.

Abbreviations: Co-Cr-Mo, cobalt-chromium-molybdenum alloy; CP-Ti, commercially pure titanium; Ti-6Al-4V, titanium alloy.

Figure 3 Viable adhered cell count of Staphylococcus epidermidis (×105/ml).Notes: Mean and standard deviation are shown. **P<0.01.Abbreviations: Co-Cr-Mo, cobalt-chromium-molybdenum alloy; CP-Ti, commercially pure titanium; Ti-6Al-4V, titanium alloy.

Discussion

In this in vitro study, we compared the capabilities of PIA-positive S. epidermidis, the preeminent cause of implant-related infection, to adhere to five types of biomaterials, investigating substratum surface properties, such as surface roughness and wettability. By defining which characteristics are important in adherence to biomaterials, it may be possible to formulate prosthetic devices that are less susceptible to bacterial adherence and less prone to infection.

The results of this study indicated that the total amount of viable bacteria that adhered to CP-Ti (16.7 ± 8.1 × 105/mL) was significantly higher than in the case of Oxinium (9.3 ± 3.0 × 105/mL) and Co-Cr-Mo (9.1 ± 5.0 × 105/mL). It is possible that the more biocompatible CP-Ti provided a more favorable surface for bacterial adherence,Citation29 whereas, it is also considered the Oxinium and Co-Cr-Mo surfaces prevented bacterial adhesion. Research has highlighted a particularly strong relationship between early bacterial adhesion and surface roughness;Citation25Citation28 however, more recent studies have reported that in vivo, surface roughness below a threshold amount (Ra =200 nm) does not affect bacterial adhesion.Citation31,Citation32 Although the extremely smooth surface of the Co-Cr-Mo (mean Ra =2.3 nm) used in this study could prevent bacterial adhesion compared with the CP-Ti (mean Ra =5.4 nm), it is difficult to say whether the difference in the mean roughness between the two materials (about 3 nm Ra) significantly affected the quantity of bacterial adhesion. In fact, the stainless steel, which had the lowest surface roughness (mean Ra =1.4 nm), showed a similar or higher degree of adhered S. epidermidis compared with Oxinium and Co-Cr-Mo (P>0.05). It can be assumed that a surface roughness of less than 10 nm Ra has only a limited influence on S. epidermidis adherence.

Surface wettability (water contact angle) is another crucial element influencing bacterial adhesion.Citation21,Citation23,Citation26 Boks et al reported that bond strengthening for four strains of S. epidermidis on a hydrophobic surface was fast and limited to a minor increase, while strengthening of the bonds on a hydrophilic surface increases significantly with contact time.Citation33 As water molecules adjacent to a hydrophobic surface are not able to form hydrogen bonds with that surface (hydrophobic effect), bacterial adhesion to a hydrophobic specimen is brought about by an entropically favorable release of water molecules. The results of this research indicated that the amount of bacteria that adhered to the more hydrophobic Co-Cr-Mo surface was significantly less than that for the rather hydrophilic CP-Ti surface. Therefore, it is possible that the difference in bacterial adhesion is derived from the surface hydrophobicity However, Tegoulia and Cooper found that a hydrophilic surface provides a stable interfacial water layer and prevents direct contact between bacteria and the surface.Citation34 Oxinium, the most hydrophilic surface, exhibited fewer adhered bacteria than CP-Ti, in the present study. These observations indicate that bacterial adhesion is a multifactorial phenomenon, and surface roughness or wettability is not the only or main material surface characteristic influencing Staphylococcal adherence. However, it may suffice to say that the relatively smooth, hydrophobic surface of the Co-Cr-Mo in our study affected bacterial adhesion. Needless to say, additional physicochemical characteristics might have some influence on these results. Further study is needed to refine these results.

Several in vitro and in vivo studies found low bacterial adhesion on zirconia ceramics, which is compositionally similar but not equal to Oxinium.Citation35,Citation36 Poortinga et al indicated that the change in substratum potential, is due to charge transfer between the substratum and the bacteria during adhesion.Citation37 With Oxinium having a ceramic surface, it is possible that the electron transfer or electrical potential may have been different from that of the other four metallic biomaterials and prevented bacterial attachment.

Several limitations must be noted in interpreting the data. The present study focused in particular on the first adherence process, before the generation of a biofilm, with quantification of the bacterial adhesion to various implants after a short period of 60 minutes. This time period corresponds to the localized adhesion of bacteria and is commonly used in microbiologic experiments that are solely focused on the bacterial adhesion process.Citation38 Since contamination during an operation is thought to be the main cause of implant-related infection, early adhesion ability is considered to be clinically important.

Other clinical strains of bacteria associated with implant-related infection do not necessarily show similar adhesion properties. Moreover, the pathogenesis of prosthetic device infections is a complex process involving interactions between the pathogen, the biomaterial, and the host. An in vitro study cannot account for host defense and other in vivo factors, such as temperature, flow condition, and nutrition. However, it was possible to make a simple comparison of bacterial adhesion capability on five kinds of material surfaces actually used in clinical practice. The results of our in vitro research suggest a lower adhesion of S. epidermidis to Oxinium and Co-Cr-Mo than to CP-Ti at a negligible roughness level. In subsequent research, we need to assess the detailed mechanisms of bacterial adhesion under more sophisticated conditions, involving other strains of bacteria. However, this study allowed greater control of the experimental variables and produced fewer artifacts in the results.

Conclusion

We compared the adherence capability of S. epidermidis on the surfaces of five types of solid biomaterial. The amounts of bacteria that adhered to the biomaterial were significantly lower for Oxinium and Co-Cr-Mo than for CP-Ti.

Acknowledgments

The authors gratefully acknowledge Smith and Nephew Richards Ltd (Cirencester, UK) for kindly contributing the test components. This work was partially supported by the Japan Society for the Promotion of Science (JSPS) KAKENHI, grant number 24592236.

Disclosure

The authors report no conflicts of interest in this work.

References

  • GristinaAGBiomaterial-centered infection: microbial adhesion versus tissue integrationScience19872374822158815953629258
  • StewartPSCostertonJWAntibiotic resistance of bacteria in biofilmsLancet2001358927613513811463434
  • MangramAJHoranTCPearsonMLSilverLCJarvisWRGuideline for prevention of surgical site infection, 1999. Centers for Disease Control and Prevention (CDC) Hospital Infection Control Practices Advisory CommitteeAm J Infect Control19992729713210196487
  • PhillipsCBBarrettJALosinaEIncidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after elective total hip replacementJ Bone Joint Surg Am200385-A1202612533567
  • SpangehlMJMasriBAO’ConnellJXDuncanCPProspective analysis of preoperative and intraoperative investigations for the diagnosis of infection at the sites of two hundred and two revision total hip arthroplastiesJ Bone Joint Surg Am199981567268310360695
  • WymengaABvan HornJRTheeuwesAMuytjensHLSlooffTJPerioperative factors associated with septic arthritis after arthroplasty. Prospective multicenter study of 362 knee and 2,651 hip operationsActa Orthop Scand19926366656711471519
  • ChuVHCrosslinDRFriedmanJYStaphylococcus aureus bacteremia in patients with prosthetic devices: costs and outcomesAm J Med200511812141616378797
  • TsukayamaDTEstradaRGustiloRBInfection after total hip arthroplasty. A study of the treatment of one hundred and six infectionsJ Bone Joint Surg Am19967845125238609130
  • ZimmerliWOchsnerPEManagement of infection associated with prosthetic jointsInfection20033129910812682815
  • MackDDaviesAPHarrisLGRohdeHHorstkotteMAKnoblochJKMicrobial interactions in Staphylococcus epidermidis biofilmsAnal Bioanal Chem2007387239940816955256
  • FluckigerUUlrichMSteinhuberABiofilm formation, icaADBC transcription, and polysaccharide intercellular adhesin synthesis by staphylococci in a device-related infection modelInfect Immun20057331811181915731082
  • HoriKMatsumotoSBacterial adhesion: From mechanism to controlBiochem Eng J2010483424434
  • AnYHFriedmanRJConcise review of mechanisms of bacterial adhesion to biomaterial surfacesJ Biomed Mater Res19984333383489730073
  • HeilmannCSchweitzerOGerkeCVanittanakomNMackDGötzFMolecular basis of intercellular adhesion in the biofilm-forming Staphylococcus epidermidisMol Microbiol1996205108310918809760
  • O’GaraJPica and beyond: biofilm mechanisms and regulation in Staphylococcus epidermidis and Staphylococcus aureusFEMS Microbiol Lett2007270217918817419768
  • GötzFStaphylococcus and biofilmsMol Microbiol20024361367137811952892
  • OlsonMEGarvinKLFeyPDRuppMEAdherence of Staphylococcus epidermidis to biomaterials is augmented by PIAClin Orthop Relat Res2006451212416906069
  • HunterGDickinsonJHerbBGrahamRCreation of oxidized zirconium orthopaedic implantsJ ASTM Int200527
  • SteinbergDSelaMNKlingerAKohaviDAdhesion of periodontal bacteria to titanium, and titanium alloy powdersClin Oral Implants Res19989267729663033
  • KatsikogianniMMissirlisYFConcise review of mechanisms of bacterial adhesion to biomaterials and of techniques used in estimating bacteria-material interactionsEur Cell Mater20048375715593018
  • BusscherHJvan der MeiHCPhysico-chemical interactions in initial microbial adhesion and relevance for biofilm formationAdv Dent Res199711124329524439
  • GottenbosBVan Der MeiHCBusscherHJGrijpmaDWFeijenJInitial adhesion and surface growth of Pseudomonas aeruginosa on negatively and positively charged poly(methacrylates)J Mater Sci Mater Med1999101285385515347964
  • BalazsDJTriandafilluKChevolotYSurface modification of PVC endotracheal tubes by oxygen glow discharge to reduce bacterial adhesionSurf Interface Anal2003353301309
  • HenriquesMAzeredoJOliveiraRAdhesion of Candida albicans and Candida dubliniensis to acrylic and hydroxyapatiteColloids Surf B Biointerfaces2004333–4235241
  • ScheuermanTRCamperAKHamiltonMAEffects of substratum topography on bacterial adhesionJ Colloid Interface Sci1998208123339820746
  • TeughelsWVan AsscheNSliepenIQuirynenMEffect of material characteristics and/or surface topography on biofilm developmentClin Oral Implants Res200617Suppl 2S68S81
  • SubramaniKJungREMolenbergAHammerleCHBiofilm on dental implants: a review of the literatureInt J Oral Maxillofac Implants200924461662619885401
  • QuirynenMvan der MeiHCBollenCMAn in vivo study of the influence of the surface roughness of implants on the microbiology of supra- and subgingival plaqueJ Dent Res1993729130413098395545
  • HaKYChungYGRyooSJAdherence and biofilm formation of Staphylococcus epidermidis and Mycobacterium tuberculosis on various spinal implantsSpine2005301384315626979
  • KajiyamaSTsurumotoTOsakiMYanagiharaKShindoHQuantitative analysis of Staphylococcus epidermidis biofilm on the surface of biomaterialJ Orthop Sci200914676977519997825
  • QuirynenMBollenCMThe influence of surface roughness and surface-free energy on supra- and subgingival plaque formation in man. A review of the literatureJ Clin Periodontol19952211147706534
  • BollenCMLambrechtsPQuirynenMComparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literatureDent Mater199713425826911696906
  • BoksNPBusscherHJvan der MeiHCNordeWBond-strengthening in staphylococcal adhesion to hydrophilic and hydrophobic surfaces using atomic force microscopyLangmuir20082422129901299418942800
  • TegouliaVACooperSLStaphylococcus aureus adhesion to self-assembled monolayers: effect of surface chemistry and fibrinogen presenceColloids Surf B: Biointerfaces2002243–4217228
  • Al-AhmadAWiedmann-Al-AhmadMFaustJBiofilm formation and composition on different implant materials in vivoJ Biomed Mater Res Part B Appl Biomater201095110110920725954
  • ScaranoAPiattelliMCaputiSFaveroGAPiattelliABacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human studyJ Periodontol200475229229615068118
  • PoortingaATBosRBusscherHJMeasurement of charge transfer during bacterial adhesion to an indium tin oxide surface in a parallel plate flow chamberJ Microbiol Methods199938318318910541431
  • MorandPCBilleEMorelleSType IV pilus retraction in pathogenic Neisseria is regulated by the PilC proteinsEMBO J20042392009201715103324