94
Views
13
CrossRef citations to date
0
Altmetric
Original Research

Toric intraocular lenses for correction of astigmatism in keratoconus and after corneal surgery

&
Pages 1153-1159 | Published online: 21 Jun 2016

Abstract

Purpose

To describe the results of cataract extraction with toric intraocular lens (IOL) implantation in patients with preexisting astigmatism from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery).

Methods

Cataract patients with topographically stable, fairly regular (although sometimes very high) corneal astigmatism underwent phacoemulsification with implantation of a toric IOL (Zeiss AT TORBI 709, Alcon Acrysof IQ toric SN6AT, AMO Tecnis ZCT). Postoperative astigmatism and refractive outcomes, as well as visual acuities, vector reduction, and complications were recorded for all eyes.

Results

This study evaluated 17 eyes of 16 patients with a mean age of 60 years at the time of surgery. Mean follow-up in this study was 12 months. The corrected distance Snellen visual acuity (with spectacles or contact lenses) 12 months postoperatively was 20/32 or better in 82% of eyes. The mean corneal astigmatism was 6.7 diopters (D) preoperatively, and 1.5 D of refractive cylinder at 1-year follow-up. No vision-compromising intra- or postoperative complications occurred and decentration or off-axis alignment of toric IOLs were not observed.

Conclusion

Phacoemulsification with toric IOL implantation was a safe and effective procedure in the three mentioned corneal conditions. Patient selection, counseling, and IOL placement with optimal astigmatism correction are crucial.

Introduction

Toric intraocular lenses (IOLs) can be used at the time of cataract surgery to decrease postoperative astigmatism. Several studies have been published on toric lenses demonstrating significant reduction in spherical and astigmatic refractive errors with good efficacy, safety, and predictability in cataract patients.Citation1,Citation2 Additionally, in selected patients with corneal conditions, toric IOL implantation showed promising results.Citation3Citation6

However, the safety and effectiveness of toric IOLs have not been fully substantiated in patients with preexisting ocular conditions. Concerns still exist regarding potentially induced higher order aberrations due to complex coupling of the IOLs toricity with the corneal irregularity. Furthermore, irregular astigmatism seems to be a relative contraindication for toric IOL implantation.Citation7

We performed this study to evaluate the visual and refractive outcomes of toric IOL implantation in cataract patients with topographically stable, although sometimes very high, corneal astigmatism resulting from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery). Correcting the refractive error in these conditions is an off-label use of toric IOLs.

Materials and methods

In this retrospective study, patients were included who underwent routine cataract surgery and toric IOL implantation between April 2011 and December 2013. All surgeries were performed by one surgeon (BVD) at the Amphia Hospital Breda, the Netherlands. Patients gave informed consent in this retrospective study for the implantation of a toric IOL. According to national regulations, obtaining institutional review board approval for conducting a retrospective study such as the present study, is not mandatory. Patients were extensively informed and consented about the procedure (orally, with written information as needed by the patient), before operation. Surgery was performed in accordance with the usual, high, clinical standards. Follow-up was performed at regular post-operative intervals and all relevant parameters were recorded.

Preoperatively, all patients underwent a complete ophthalmic evaluation including subjective refraction, Snellen best-corrected distance visual acuity (BCVA), applanation tonometry, slit-lamp examination, funduscopy, and corneal topography (type 70900, Pentacam HR, Oculus Optikgeräte GmbH, Wetzlar, Germany). Optical biometry was measured with the IOLMaster (Carl Zeiss Meditec AG, Jena, Germany) and if this was not possible due to the density of the cataract, it was measured by A scan ultrasonography (Nidek US-500, Gamagori, Japan). Endothelial cell counts were evaluated by confocal microscopy (Confoscan 4, Nidek, Padova, Italy) for all patients.

Inclusion and exclusion criteria

Inclusion criteria for toric IOL implantation were visually significant cataract, fairly regular corneal astigmatism of 1.25 D or more, a bow tie-like pattern on corneal topography and corneal-based astigmatism correctable with spectacles. Refraction had to be stable during multiple tomography examinations (total corneal refractive power map). Stable and nonprogressive astigmatism over a 6-month period was defined as no >1.00 D variation in the maximum topographic keratometry (K) value. After corneal surgery, this definition was used on the precondition of complete suture removal.

Exclusion criteria included endothelial cell count <1,500/mm2, irregular astigmatism unable to be corrected with spectacles and ocular comorbidities that could have an impact on capsular bag stability, affect visual acuity, or the quality of vision. The severity of keratoconus was classified as mild, moderate, or severe according to the average K readings and based on the classification of Krumeich et al.Citation8 Patients with severe keratoconus (average K readings >55 D) were excluded from this study.

Surgical technique

Surgery was performed using sub-Tenon’s anesthesia, except for one patient who preferred general anesthesia. Before the sub-Tenon’s block, the 3, 6, and 9 o’clock corneal markings were made with Nuijts–Lane Toric Reference Marker (AE-2791TBL, ASICO, Westmont, IL, USA) under topical anesthesia. Patients were instructed to sit upright and look forward to avoid supine cyclotorsion. Intraoperatively, the location of the corneal incision and axis of IOL placement was marked using Mendez degree gauge (AE-2765N, ASICO) and a Nuijts–Solomon Toric Axis Marker (AE-2740N, ASICO). A superotemporal near-clear corneal incision was created in the keratoconus and postpterygium patients; corneoscleral incisions were made in postkeratoplasty patients. This was followed by injection of an ophthalmic viscosurgical device, capsulorhexis, pha-coemulsification, bimanual irrigation/aspiration of cortical material, filling of the capsular bag with viscoelastic material, toric IOL implantation and thorough irrigation and aspiration, ensuring complete removal of residual viscoelastic behind the IOL as the standard procedure. During surgery, a dispersive ophthalmic viscosurgical device (hydroxypropyl methylcellulose 2%, Viscomet, Sun Pharmaceuticals Industries Ltd, Mumbai, India) was used to protect the endothelium. The toric IOL was aligned with the corneal marks and a final check was made when the incisions were hydrated. Postoperatively, a standard regimen of topical nonsteroidal and steroid anti-inflammatory drops was used.

Toric IOLs and power calculation

Toric IOLs were used from three different manufacturers: AT TORBI 709 (Carl Zeiss Meditec AG), Tecnis Toric ZCT IOL (Abbott Medical Optics, Inc, Santa Ana, CA, USA), and Acrysof SN6AT toric IOL (Alcon Laboratories, Inc., Fort Worth, TX, USA). All the three types are single-piece toric IOLs. Because of its cylinder power range (+12.00 D to +1.00 D), Zeiss AT TORBI 709 was used for cataract patients with high amounts of corneal astigmatism. In the beginning, Acrysof SN6AT was placed in cataract patients with moderate amounts of astigmatism because it was the most readily available toric IOL. In the later years, AMO Tecnis ZCT toric IOL became our standard IOL for cataract patients with moderate astigmatism.

Patient assessment and postoperative follow-up

Preoperative biometry and topographic keratometry, the expected amount of surgically induced astigmatism, and the site of incision were used to determine the appropriate toric IOL model, alignment axis, and spherical equivalent (SE) power. The Haigis formula was used as the main method for spherical IOL power calculation and compared with the SRK/T, Hoffer-Q, and Holladay 1 formulas.Citation9Citation13 Toric IOL power calculation and orientation placement were performed using the software provided by the manufacturer of the IOLs.Citation14Citation16

Analysis

Patients were seen 1 day, 1 week, and 1, 3, 6, and 12 months after cataract surgery whenever possible. All eyes were examined at each postoperative visit, including visual acuity, refraction, applanation tonometry, and slit-lamp examination. Postoperatively, the orientation axis of the toric IOL was determined by using the biomicroscope and full mydriasis of the pupil.

Visual outcomes are presented in the form of BCVA with spectacles or contact lenses. Refractive data are provided in the form of sphere, positive cylinder, and cylinder axis. For analysis purposes, visual acuities were converted from Snellen acuity to logMAR.Citation17

Based on the results, we calculated the safety index (ratio of postoperative BCVA over preoperative BCVA). The efficacy index (ratio of postoperative uncorrected visual acuity over preoperative BCVA) could not be examined due to lack of standardized postoperative uncorrected visual acuity data in this retrospective study.

A full description of refractive error was done with the three-dimensional vector that takes into account magnitude and axis of astigmatism as well as the spherical component. Therefore, spherocylindrical refraction results (S [sphere], C [cylinder], α [axis]) were converted to power vector coordinates M, J0, and J45 by the following formulas: M=S+C/2(1) J0=(C/2)*cos(2α)(2) J45=(C/2)*sin(2α),(3) where M is equal to the SE of the given refractive error; J0 is the Jackson cross-cylinder, axes at 90° and 180°; J45 is the Jackson cross-cylinder, axes at 45° and 135°.Citation18Citation20

Results

We retrospectively studied 17 eyes of 16 patients, four (25%) females and 12 (75%) males. Mean patient age at the time of surgery was 60±11 years. shows the demographic data prior to surgery, types, and parameters of implanted lenses. The AMO ZCT toric IOL was implanted in six patients (six eyes), Zeiss AT TORBI 709 in four patients (five eyes), and six patients (six eyes) received the Alcon Acrysof IQ toric SN6AT toric IOL.

Table 1 Baseline parameters

Complications

No vision-compromising intraoperative complications occurred. One patient suffered from postoperative macula-on retinal detachment, which could be surgically repaired without loss of vision. Decentration or off-axis alignment of the toric IOL was not observed, and no graft had rejection episodes.

Visual acuity

Visual outcomes are presented in BCVA (or contact lens visual acuity in one patient). shows the BCVA before toric IOL implantation and after a mean follow-up period of 12 months postoperatively. The mean BCVA was 0.59±0.44 logMAR preoperative and 0.13±0.13 logMAR 1 year postoperative. The corrected distance Snellen visual acuity 12 months postoperatively was 20/32 (0.6) or better in 14 eyes (82%) and 20/25 (0.8) or better in ten eyes (59%).

Figure 1 Preoperative versus 12-month postoperative BCVA.

Abbreviation: BCVA, best-corrected visual acuity.
Figure 1 Preoperative versus 12-month postoperative BCVA.

Refraction

The mean refractive SE decreased from −3.10±3.95 D preoperatively to 0.22±1.53 D postoperatively.

Safety

The safety results for toric IOL implantation are presented in . There was loss of one line in one patient, likely due to a macular pucker with metamorphopsia. All other eyes gained two lines or more. The mean safety index was 4.88±8.02.

Figure 2 Changes in BCVA (Snellen chart) after 12 months of toric intraocular lens implantation.

Note: *Comorbidity: macular pucker with metamorphopsia (postoperative BCVA 0.6).
Abbreviation: BCVA, best-corrected visual acuity.
Figure 2 Changes in BCVA (Snellen chart) after 12 months of toric intraocular lens implantation.

Predictability

shows the distribution of manifest preoperative corneal astigmatism and the refractive cylinder at a mean of 12 months postsurgery. The mean refractive cylinder decreased from 6.3±4.7 D preoperatively to 1.5±1.5 D at 1 year after toric IOL implantation.

Figure 3 Preoperative corneal astigmatism versus 12-month postoperative refractive cylinder distribution in diopters (D).

Figure 3 Preoperative corneal astigmatism versus 12-month postoperative refractive cylinder distribution in diopters (D).

Vector analysis

shows the scatter plot of the astigmatic vectors (J0, J45) before and after toric IOL implantation. The more central location of postoperative data around 0 represents the reduction of preoperative astigmatism by the implantation of the toric implantable IOL. The value (0,0) represents an eye free of astigmatism. Mean M dropped from 3.1±3.9 to 0.1±1.5. J0 dropped from 0.9±0.9 to −0.1±0.3. J45 changed from 0.7±0.6 to −0.1±0.5.

Figure 4 Scatter plot of the astigmatic vectors (J0 and J45) before and after toric intraocular lens implantation.

Figure 4 Scatter plot of the astigmatic vectors (J0 and J45) before and after toric intraocular lens implantation.

Patient satisfaction

Overall, patient satisfaction was fairly good for most patients. Although phacoemulsification and toric IOLs implantation did not provide total refractive correction, most patients were pleased with the improvement they experienced. In our group of patients, slight residual refraction error was well tolerated and wearing spectacles or contact lenses usually was not a problem. Two patients were less satisfied because of comorbidity from a macular pucker (n=1) and the additional need for a scleral contact lens because of the residual anisometropia (n=1). By using the scleral contact lens, the patient achieved a postoperative BCVA of 20/30 (0.7).

Initially, one patient was less satisfied because of the conversion from myopia to slight hypermetropia (SE + 1.0 D, target was emmetropia). This patient went back to isometropia after cataract surgery of the other eye and was happy wearing multifocal spectacles.

Discussion

In our series, phacoemulsification with toric IOL implantation for visually significant cataract was a safe and effective procedure in the three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery). Our results are in agreement with previously published case reports and series on toric IOL implantation for correcting postkeratoplasty astigmatism and keratoconus in cataract patients.Citation3,Citation6,Citation21Citation27

To our knowledge, no previous studies reported the outcomes of toric IOL implantation in patients having phacoemulsification after previous pterygium surgery. Furthermore, most of the available literature reports results from only the Acrysof toric IOL since this is one of the most commonly used toric IOL in cataract surgery. We, however, were able to show the safety and effectiveness of toric IOLs from three different manufacturers.

In our series, one male patient suffered from macula-on retinal detachment about 5 weeks postoperatively. Fortunately, the detachment was recognized early and repaired before loss of vision occurred. This complication was one typically associated with cataract surgery and high myopia.Citation28 Our myopic keratoconus patient had an axial length of 27.99 mm and therefore was prone to retinal detachment.

In this study, toric IOL implantation was only considered in patients with stable corneal pathology and fairly regular astigmatism. Extensive preoperative corneal topography, including total corneal power analysis and several consecutive examinations over a longer time period, is crucial. If endothelial graft failure should occur, the existing refractive situation after insertion of a toric IOL may be maintained by proceeding with endothelial keratoplasty.

For patients who wish to continue to wear a contact lens after surgery, there is uncertainty as to the optimum target for postoperative refraction for optimal postoperative contact lens fit. If a patient wants to return to a rigid (bi)toric or scleral contact lens after toric IOL implantation, the astigmatism of the IOL will become manifest. A bitoric rigid gas permeable design may then be necessary. Alternatively, the toric IOL may be exchanged for a spherical IOL design.Citation29 Therefore, it should be emphasized that toric IOL implantation is a suitable option only in patients with astigmatism who can be satisfactorily corrected with spectacles and have realistic expectations.

In most cases, the treatment provided was not expected to fully correct the patient’s eyesight to emmetropia. It is advisable to remain on the conservative (myopic) side with choice of target SE. Slight residual astigmatism may also be beneficial because of increased depth of focus. Our patients were counseled regarding the limitations of the toric IOL in fully correcting the astigmatism. The operating surgeon should be aware of the tendency toward hyperopic outcomes in any cataract surgery in steep keratoconic corneas. Biometry in eyes with severe keratoconus will typically overestimate the corneal power and underestimate the IOL power, with a tendency to postoperative hyperopic biometry prediction error.Citation8,Citation30 Therefore, we only included patients with mild and moderate amounts of keratoconus.

It is not surprising that, in the present study, there was a large reduction in the mean refractive SE. The decrease in the magnitude of astigmatism reflects that the toric IOLs effectively addressed that component. The decrease from −3.10±3.95 D preoperatively to a postoperative SE of 0.22±1.53 D reflects successful reduction in astigmatism with some cases of mild overcorrection. This stresses the importance of a myopic target with the postoperative hyperopic prediction error as described earlier.

The technique we used to mark the axis of IOL alignment preoperatively and confirm alignment by using the biomicroscope postoperatively is not flawless. However, we did not find significant rotational misalignment at last follow-up, which is in agreement with previously published reports showing good rotational stability for the three types of toric IOLs.Citation2,Citation31Citation33

Mean safety index was 4.88±8.02. When analyzing this high value, especially the amount of standard deviation, it is important to take into account the fact that the improvement in BCVA derives not only from the correction of refractive astigmatism, but also from the removal of cataract. The BCVA of one patient increased from distinguishing hand movements at a distance of 10 feet to a postoperative BCVA of 20/63. Due to this specific case, the standard deviation increased.

Our vector analysis was based on the three-dimensional vector that takes into account magnitude and axis of astigmatism, as well as the spherical component. Because astigmatism analysis is multidimensional, it is not possible to capture the nuances in a single graphical display. There are other, possibly superior, methods of reporting on the manifest refractive astigmatism before and after a procedure. Given the complexity of analyzing astigmatism, there are inevitable differences between these approaches; so far, absolute agreement on a standard has not been reached.Citation34

We acknowledge that there are limitations to this retrospective study. There is a degree of heterogeneity in our cohort of patients and the cohort is small, which makes basic statistical comparison inappropriate. However, we believe that we were able to show meaningful long-term visual and refractive results with overall good patient satisfaction. As always, careful patient selection and thorough and complete patient information are paramount.

Acknowledgments

Presented at the World Cornea Congress VII (WCCVII), San Diego, CA, April 2015.

Disclosure

The authors did not receive any financial support from any public or private sources. The authors have no financial or proprietary interest in a product, method, or material described herein. The authors report no conflicts of interest in this work.

References

  • HoffmannPCAuelSHützWWResults of higher power toric intraocular lens implantationJ Cataract Refract Surg20113781411141821703818
  • MiyakeTKamiyaKAmanoRIidaYTsunehiroSShimizuKLong-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatismJ Cataract Refract Surg201440101654166025149554
  • VisserNGastSTBauerNJNuijtsRMCataract surgery with toric intraocular lens implantation in keratoconus: a case reportCornea201130672072321562460
  • LuckJCustomized ultra-high-power toric intraocular lens implantation for pellucid marginal degeneration and cataractJ Cataract Refract Surg20103671235123820610106
  • KerseyJPO’DonnellAIllingworthCDCataract surgery with toric intraocular lenses can optimize uncorrected postoperative visual acuity in patients with marked corneal astigmatismCornea200726213313517251799
  • StewartCMMcAlisterJCComparison of grafted and non-grafted patients with corneal astigmatism undergoing cataract extraction with a toric intraocular lens implantClin Experiment Ophthalmol201038874775720497428
  • KuglerLJSztipanovitsDWangMContraindications to implantation of toric IOLsRefrac Eyecare20111532628
  • KrumeichJHDanielJKnülleALive-epikeratophakia for keratoconusJ Cataract Refract Surg19982444564639584238
  • HaigisWLegeBMillerNSchneiderBComparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisGraefes Arch Clin Exp Ophthalmol2000238976577311045345
  • PetermeierKGekelerFMessiasASpitzerMSHaigisWSzurmanPIntraocular lens power calculation and optimized constants for highly myopic eyesJ Cataract Refract Surg20093591575158119683155
  • RetzlaffJASandersDRKraffMCDevelopment of SRK/T intraocular lens implant power calculation formulaJ Cataract Refract Surg19901633333402355321
  • HofferKJThe Hoffer Q formula: a comparison of theoretic and regression formulasJ Cataract Refract Surg19931967007128271165
  • HolladayJTPragerTCChandlerTYMusgroveKHLewisJWRuizRSA three-part system for refining intraocular lens power calculationsJ Cataract Refract Surg198814117243339543
  • AcrySof®Toric IOL Web Based Calculators Available from: http://www.acrysoftoriccalculator.com/
  • Abbott Laboratories IncAMO IOL Calculator Platform Available from: http://amoeasy.com/calc
  • Carl Zeiss Meditec IOLMaster OnlineToric IOL Calculator Available from: http://www.zeiss.com/iolmaster-online
  • HolladayJTProper method for calculating average visual acuityJ Refract Surg19971343883919268940
  • ThibosLNHornerDPower vector analysis of the optical outcome of refractive surgeryJ Cataract Refract Surg2001271808511165859
  • MertensELToric phakic implantable collamer lens for correction of astigmatism: 1-year outcomesClin Ophthalmol2011536937521468348
  • ThibosLNWheelerWHornerDPower vectors: an application of Fourier analysis to the description and statistical analysis of refractive errorOptom Vis Sci19977463673759255814
  • NavasASuárezROne-year follow-up of toric intraocular lens implantation in forme fruste keratoconusJ Cataract Refract Surg200935112024202719878840
  • De SanctisUEandiCGrignoloFPhacoemulsification and customized toric intraocular lens implantation in eyes with cataract and high astigmatism after penetrating keratoplastyJ Cataract Refract Surg201137478178521420606
  • BuchwaldHJLangGKCataract surgery with implantation of toric silicone lenses for severe astigmatism after keratoplastyKlin Monbl Augenheilkd2004221648949415236110
  • FrohnADickHBThielHJImplantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatismJ Cataract Refract Surg199925121675167810609215
  • LockingtonDWangEFPatelDVMooreSPMcGheeCNEffectiveness of cataract phacoemulsification with toric intraocular lenses in addressing astigmatism after keratoplastyJ Cataract Refract Surg201440122044204925283612
  • HashemiHHeidarianSSeyedianMAYektaAKhabazkhoobMEvaluation of the results of using toric IOL in the cataract surgery of keratoconus patientsEye Contact Lens201541635435825946379
  • WadeMSteinertRFGargSFaridMGasterRResults of toric intraocular lenses for post-penetrating keratoplasty astigmatismOphthalmology2014121377177724321143
  • RussellMGaskinBRussellDPolkinghornePJPseudophakic retinal detachment after phacoemulsification cataract surgery: ten-year retrospective reviewJ Cataract Refract Surg200632344244516631054
  • WatsonMPAnandSBhogalMCataract surgery outcome in eyes with keratoconusBr J Ophthalmol201498336136423966369
  • AlpinsNOnjJKStamatelatosGRefractive surprise after toric intraocular lens implantation: graph analysisJ Cataract Refract Surg201440228329424461500
  • BascaranLMendicuteJMacias-MurelagaBArbelaitzNMartinez-SoroaIEfficacy and stability of AT TORBI 709 M toric IOLJ Refract Surg201329319419923446016
  • FerreiraTBAlmeidaAComparison of the visual outcomes and OPD-scan results of AMO Tecnis toric and Alcon Acrysof IQ toric intraocular lensesJ Refract Surg201228855155522785061
  • HirnschallNMaedelSWeberMFindlORotational stability of a single-piece toric acrylic intraocular lens: a pilot studyAm J Ophthalmol2014157240541124332372
  • ReinsteinDZArcherTJRandlemanJBJRS standard for reporting astigmatism outcomes of refractive surgeryJ Refract Surg2014301065465925291747