51
Views
1
CrossRef citations to date
0
Altmetric
Original Research

No differences in central corneal thickness between open-angle and pseudoexfoliation glaucoma patients

&
Pages 733-738 | Published online: 19 Apr 2017

Abstract

Introduction

Measurements of intraocular pressure (IOP) with Goldmann applanation tonometry are affected by central corneal thickness (CCT), as thinner corneas underestimate and thicker corneas overestimate the true IOP value. The literature is controversial regarding CCT values in patients with primary open-angle glaucoma (POAG) and exfoliation glaucoma (XFG). The aim of this study was to evaluate CCT in patients with XFG and POAG.

Methods

CCT was evaluated with optical coherence tomography (OCT). All participants who were previously diagnosed with either POAG or XFG underwent ophthalmological examinations. Contact lens users and patients with corneal diseases were excluded.

Results

Totally, 145 patients were enrolled in this study. The mean CCT was 535±30.4 µm in patients with POAG and was 536±33.7 µm in patients with XFG. The result was not statistically significant (P=0.98). The mean age for all participants was 73.8±7.7 years. The study included totally 61 women and 84 men. The two groups were similar in their demographic data, and mean deviation was the only parameter that differed statistically when comparing POAG with XFG (P=0.02).

Conclusion

Our data indicate that patients with XFG do not have thinner corneas than those with POAG, and therefore, CCT can not explain why they progress differently.

Introduction

Glaucoma is the second leading cause of blindness worldwide.Citation1 It consists of a heterogeneous group of diseases, all characterized by optic-nerve damage causing irreversible visual field loss and vision impairment, which slowly can progress to blindness if not treated.Citation2 Open-angle glaucoma (OAG) is the most common form of glaucoma in the Western world.Citation1

The etiology of OAG is still unknown, but genetic and environmental risk factors are thought to be involved.Citation3,Citation4 The intraocular pressure (IOP) is considered to be the most important risk factor for developing glaucoma.Citation5 IOP is an important factor for monitoring glaucoma treatment and determining glaucoma severity,Citation6 and it is also the only treatable risk factor. Other risk factors are, for example, older age, thin central cornea, ethnicity, family history and pseudoexfoliation.Citation5,Citation7Citation9

There are different types of OAG, of which the most common type is primary open-angle glaucoma (POAG).Citation2 Exfoliative glaucoma (XFG) is a secondary form of OAG with faster progression and worse prognosis than POAG.Citation10,Citation11 XFG is characterized by accumulation of abnormal fibers in the anterior segment of the eye, causing disrupted drainage of aqueous humor and elevation of IOP.Citation11 The progression of XFG is correlated with the level of IOP, and patients with XFG more often require not only medical treatment but also laser and surgery to lower the IOP.Citation12 By lowering IOP in patients with OAG, further progression of this condition can be prevented or delayed.Citation13Citation15

The “gold standard” method to measure IOP is Goldmann applanation tonometry (GAT). It is well known that measurements of IOP with GAT are affected by central corneal thickness (CCT), as thinner corneas underestimate and thicker corneas overestimate the true IOP value.Citation16Citation18 Moreover, thinner CCT has been shown to be a predictor for the development of POAG in patients with ocular hypertension.Citation5 Patients with thinner corneas are more likely to have visual field progressionCitation19 and a worse visual field defect.Citation20

The CCT differs in different populationsCitation21 and in different types of glaucoma.Citation22 Genetic factors have been shown to be of major importance in CCT.Citation23 It has been shown that Afro-Americans have a thinner CCT than other populations.Citation21,Citation24,Citation25 However, the literature is controversial regarding the differences in corneal thickness in patients with POAG and XFG. Some studies have shown eyes with XFG to have thinner CCT compared to POAG and/or normal eyes,Citation21,Citation22,Citation26Citation29 while other studies have found thicker CCT in XFG compared to POAG and/or normal eyes.Citation30Citation34

The aim of this study was to evaluate central corneal thickness in patients with XFG and POAG.

Methods

Study protocol

A comprehensive medical and ocular history was obtained from patients. Ophthalmological examination was performed before including these patients in the study. Visual acuity, IOP measurements, optic-nerve status, gonioscopy, Humphrey visual fields (HFA, 24-2) and presence or absence of exfoliation were recorded. Visual acuity was recorded using Snellen’s chart. IOP was measured using a Goldmann applanation tonometer. Three measurements were done and the average value was calculated. Then, the pupils were dilated and exfoliation was checked and recorded as present or absent. Afterward, the optic-nerve status was evaluated using a 90-D lens, and hence, stereo photographs were taken. Previous eye surgery was also registered.

Glaucoma was defined, following the European guidelines for glaucoma, as the presence of at least two repeatable Humphrey visual fields showing glaucoma damage in patients, using the software 24-2 and the optic nerve showing typical glaucoma damage.Citation35 Demographic data, such as gender, age, ocular history, visual field and number of antiglaucomatous medical methods, were also recorded. Inclusion criteria were patients who were previously diagnosed with POAG or XFG according to their medical records. Diagnosis was based on optic disc appearance and visual field damage. Subjects were excluded if they were contact lens users or had any corneal disease.

POAG was defined as the condition, as above, without the presence of exfoliation in dilated pupil. XFG was defined as open angle, concomitant with the presence of exfoliation material, a grayish-white material, observed at the anterior lens capsule and/or at the pupillary border with dilated pupil. Patients who were operated for cataract were diagnosed with exfoliation before cataract operation.

CCT was measured by optical coherence tomography (OCT, 3D OCT-2000 and 3D OCT-1000; Topcon Corporation, Tokyo, Japan) using the anterior segment imaging protocol. Only images of good quality were recorded (>60 signal strength). CCT was measured by two examiners, a senior consultant ophthalmologist (M.A.) and a medical student (J.K.). The measurements were done during the daytime, from 8 am to 5 pm. Both eyes were measured in all patients once. If patients had bilateral glaucoma, one eye was later randomly selected to be included in the statistical analysis.

Statistical methods

Statistical analysis was performed with SSPS (SPSS, Chicago, IL, USA). First, the data were tested for normality using the Kolmogrov–Smirnov test. Then, the data were tested for equality of variance using Levene’s test. Student’s t-test was used to compare CCT values and demographic data between patients with POAG and XFG. For comparison of gender between the two groups, a chi-squared test was used. Averages ± standard deviations (SDs) were used to report data. A P-value of 0.05 or less was considered to be statistically significant. Sample size was estimated to be 63 individuals in each group with a significance level of 0.05 and power of 90%.

Ethical considerations

Ethical approval was received from the Institutional Review Board (Ethical approval number: 717-13), Gothenburg University, Gothenburg, Sweden. The study followed the tenets of the Declaration of Helsinki. A written informed consent was obtained from all patients who participated in this study, and their medical records were controlled, before they were included into this study.

Results

Totally, 145 patients were included in this study between December 2013 and December 2016. Of them, 66 patients were diagnosed with POAG and 79 with XFG. All patients were born in Scandinavia. The mean age for all participants was 73.8±7.7 years, and the age range was 52–93 years. There were totally 61 women and 84 men included in this report. The demographic properties of two glaucoma groups are presented in .

Table 1 Demographic data of the study groups

The two groups were similar in their demographic data, and mean deviation (MD) was the only parameter that differed statistically when comparing POAG with XFG (P=0.02).

Regarding CCT, the data are found to be normally distributed (Kolmogrov–Smirnov; P=0.20), and the variances between the groups are shown to be equal (Levene’s test; P=0.36). The mean CCT was 535±30.4 µm in patients with POAG and was 536±33.7 µm in patients with XFG. The result was not statistically significant (t-test; P=0.98). The mean was adjusted for confounding factors. The adjusted mean was 469.40 µm in POAG patients and was 480.04 µm in XFG patients.

Data from four patients were excluded due to difficulties in recording of the measurements (n=3) and failure of the equipment (n=1).

Discussion

Central corneal thickness is a well-known factor affecting IOP readings with GAT. It was earlier shown by Goldmann and SchmidCitation36 and Ehlers et alCitation37 that IOP readings with GAT could give falsely elevated or decreased IOP readings depending on the corneal thickness. Ehlers et alCitation37 reported that accurate measurements only were given at a central corneal thickness of 520 µm. They found that for each 10 µm it varies from 520 µm, a correction of 0.7 mm Hg is needed. Other reports have later revealed average correction to be lower, namely 0.18–0.23 mmHg,Citation38 0.19 mmHgCitation39 and 0.5 mmHg per 10 µm.Citation40

CCT values among normal individuals without glaucoma vary and are normally found to be 540±30 µm.Citation40Citation42 The literature is controversial regarding CCT in patients with POAG and XFG and how they correlate with each other and with normal individuals without glaucoma. In our report, no statistical significant differences in CCT could be detected between these glaucoma types. These results are in concordance with other reports. Studies by Tolesa and Gessesse,Citation30 Ventura et al,Citation31 Shah et alCitation32 and Ozkok et alCitation33 did not find any significant difference in corneal thickness between XFG and POAG. Tolesa and GessesseCitation30 found, in their multiethnic report, thicker CCT in patients with POAG (520±38.95 µm) compared to XFG (507±35), but these results were not significant. In the report by Ventura et al,Citation31 the mean CCT was 515±35 µm in eyes with POAG and was 507±25 µm in XFG. Shah et alCitation32 reported mean CCT to be 530.7 µm in XFG and 550.1 µm in POAG, and Ozkok et alCitation33 546±34.9 µm vs 550±25 µm. In this study, we found the mean CCT to be 536±33.7 µm in XFG eyes and 535±30.4 µm in POAG eyes. Previous reports cited in this articleCitation6,Citation18,Citation21,Citation22,Citation26Citation33,Citation43 have reported mean CCT in patients with XFG to be between 493–546 µm and 507–556 µm. Our results accord with previous studies.

Reports by Kitsos et al,Citation26 Bechmann et al,Citation28 Gorezis et alCitation22 and KniestedtCitation29 found CCT to be significantly lower in XFG compared to POAG. They had included only 32, 24, 50 and 12 XFG patients, respectively. No evidence was found in the literature about published studies comparing XFG to POAG with the same number of XFG patients than the ones included in this report. Furthermore, according to our estimation of sample size, 63 individuals in each group with significance of 0.05 and power of 90% were needed. Often, estimation of sample size has not been included in previous studies, which may contribute to explain why some studies found a difference and some not in CCT between POAG and XFG. Another possible explanation about the small number of XFG included in previous studies may be that XFG is quite common in Scandinavian countries. It might be difficult to recruit enough number of participants in studies performed in other countries, and therefore, leading to too small sample size of exfoliation patients.

Disagreement between studies could be explained by different techniques used to measure CCT. Currently, CCT can be measured by ultrasound pachymetry (USP), optical low-coherence reflectometry (OLCR), anterior segment optical coherence tomography and Scheimpflug camera. Comparison in CCT between XFG and POAG has mostly been done using USP.Citation26,Citation30,Citation32,Citation33 Bechmann et alCitation28 used OCT, Ventura et alCitation31 used OLCR and Gorezis et alCitation22 used a pecular microscope. USP is currently the gold standard for measuring corneal thickness, but it has some limitations. The examiner must place the probe at the exact same position at the center of the cornea, otherwise a different CCT value will be obtained.Citation44 It also requires topical anesthesia before measurement can be accomplished, which can affect cornea and the results.Citation45 OCT has the advantages of being a noninvasive, noncontact technique, and therefore, no topical anesthesia is needed to perform the measurement. It is also less affected by the examiner’s knowledge and experience, and has high degree of repeatability and reproducibility.Citation46 Additionally, incorrect placement of a probe cannot bias OCT results.Citation47

Previous reports have shown that OCT gives lower CCT readings compared to ultrasound.Citation47Citation49 The opposite, overestimation with OCT compared to USP has also been reported.Citation50,Citation51 Wells et alCitation48 compared optical pachymetry, OCT and ultrasound, and found that these devices are not interchangeable in clinical practice. Garcia-Medina et alCitation49 compared Fourier-Domain OCT with USP in 80 patients with POAG and found a significant difference between the mean CCT. However, they indicated that this difference should not be clinically significant in IOP estimation. There is also a report by Adibelli et al,Citation51 showing a significant difference between OCT and USP in 26 POAG patients, where mean CCT was higher with OCT compared to USP. Comparison by Ayala and StrandåsCitation50 between OCT and USP did not show any difference between these two devices. However, this might be a reason for different outcomes when measuring CCT worldwide. As reported by Wells et al,Citation48 CCT can vary up to 30 µm when using different instruments.

There is a lack of information in the literature about how interchangeable the devices are concerning XFG patients. Maybe, the exfoliation material at the endothelium disturbs the measurement with OCT, creating a false thicker cornea and, therefore, we did not find any difference between these two glaucoma types. Further studies are needed to investigate the issue. However, in our study patients suffering from POAG and XFG were measured with the same technique (OCT) minimizing the risk of bias. Regarding demographic data, our two groups were very similar. Only mean deviation differed statistically. This is in concordance with The Early Manifest Glaucoma Trial, showing a faster progression rates in MD in patients with XFG than in POAG.Citation52

The study has several limitations. The examiners were not blinded to condition the patient had, and therefore there are some risks for bias. The fact that two different examiners performed the measurements can induce certain bias to the study. However, a recent study by the same author has shown that there are no differences between the examiners measuring with OCT.Citation50 There is also risk of selection bias as the recruitment of the patients was performed at an eye clinic. Variation in measurements due to lack of patients’ cooperation may also be a limitation. During measurements with OCT, the patient should be able to focus her or his gaze on something during the measurement. This was difficult only for a few patients because of the inability to understand instructions owing to very poor hearing or dementia. However, the same difficulties would be present in the both glaucoma types included. Another possible bias in the study was that patients were recruited directly from the clinic, and patients were in different stages of their illnesses as same as using different amount of eye drops.

Conclusion

Our data indicate that patients with XFG do not have thinner corneas than those with POAG, and therefore CCT can not explain why they progress differently.

Acknowledgments

The authors thank the Skaraborg Hospital Research Center for support.

Disclosure

The authors report no conflicts of interest in this work.

References

  • QuigleyHABromanATThe number of people with glaucoma worldwide in 2010 and 2020Br J Ophthalmol200690326226716488940
  • WeinrebRNKhawPTPrimary open-angle glaucomaLancet200436394221711172015158634
  • YilmazSGPalamarMOnayHLOXL1 gene analysis in Turkish patients with exfoliation glaucomaInt Ophthalmol201636562963526758070
  • PasqualeLRKangJHWiggsJLProspects for gene-environment interactions in exfoliation syndromeJ Glaucoma2014238 Suppl 1S64S6725275911
  • GordonMOBeiserJABrandtJDThe Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucomaArch Ophthalmol20021206714720 discussion 829–83012049575
  • HerndonLWWeizerJSStinnettSSCentral corneal thickness as a risk factor for advanced glaucoma damageArch Ophthalmol20041221172114718289
  • AllinghamRRLoftsdottirMGottfredsdottirMSPseudoexfoliation syndrome in Icelandic familiesBr J Ophthalmol200185670270711371492
  • LeAMukeshBNMcCartyCATaylorHRRisk factors associated with the incidence of open-angle glaucoma: the visual impairment projectInvest Ophthalmol Vis Sci20034493783378912939292
  • WolfsRCKlaverCCRamrattanRSvan DuijnCMHofmanAde JongPTGenetic risk of primary open-angle glaucoma. Population-based familial aggregation studyArch Ophthalmol199811612164016459869795
  • HymanLHeijlALeskeMCBengtssonBYangZEarly Manifest Glaucoma Trial GroupNatural history of intraocular pressure in the early manifest glaucoma trial: a 6-year follow-upArch Ophthalmol2010128560160720457982
  • RitchRSchlötzer-SchrehardtUExfoliation syndromeSurv Ophthalmol200145426531511166342
  • KonstasAGStewartWCStromanGASineCSClinical presentation and initial treatment patterns in patients with exfoliation glaucoma versus primary open-angle glaucomaOphthalmic Surg Lasers19972821111179054481
  • HeijlALeskeMCBengtssonBHymanLBengtssonBHusseinMEarly Manifest Glaucoma Trial GroupReduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma TrialArch Ophthalmol2002120101268127912365904
  • KassMAHeuerDKHigginbothamEJThe Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucomaArch Ophthalmol20021206701713 discussion 829–83012049574
  • LeskeMCHeijlAHymanLBengtssonBDongLYangZEMGT GroupPredictors of long-term progression in the early manifest glaucoma trialOphthalmology2007114111965197217628686
  • StodtmeisterRApplanation tonometry and correction according to corneal thicknessActa Ophthalmol Scand19987633193249686845
  • LeeMAhnJEffects of central corneal stromal thickness and epithelial thickness on intraocular pressure using Goldmann applanation and non-contact tonometersPLoS One2016113e015186826998838
  • YagciREksiogluUMidilliogluIYalvacIAltiparmakEDumanSCentral corneal thickness in primary open angle glaucoma, pseudoexfoliative glaucoma, ocular hypertension, and normal populationEur J Ophthalmol200515332432815944999
  • KimJWChenPPCentral corneal pachymetry and visual field progression in patients with open-angle glaucomaOphthalmology2004111112126213215522381
  • IesterMTelaniSFrezzottiPItalian Glaucoma RegisterDifferences in central corneal thickness between the paired eyes and the severity of the glaucomatous damageEye (Lond)201226111424143022975658
  • AghaianEChoeJELinSStamperRLCentral corneal thickness of Caucasians, Chinese, Hispanics, Filipinos, African Americans, and Japanese in a glaucoma clinicOphthalmology2004111122211221915582076
  • GorezisSChristosGStefaniotouMMoustaklisKSkyrlasAKitsosGComparative results of central corneal thickness measurements in primary open-angle glaucoma, pseudoexfoliation glaucoma, and ocular hypertensionOphthalmic Surg Lasers Imaging2008391172118254346
  • TohTLiewSHMacKinnonJRCentral corneal thickness is highly heritable: the twin eye studiesInvest Ophthalmol Vis Sci200546103718372216186354
  • La RosaFAGrossRLOrengo-NaniaSCentral corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populationsArch Ophthalmol20011191232711146722
  • ShimmyoMRossAJMoyAMostafaviRIntraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African AmericansAm J Ophthalmol2003136460361314516799
  • KitsosGGartziosCAsproudisIBagliECentral corneal thickness in subjects with glaucoma and in normal individuals (with or without pseudoexfoliation syndrome)Clin Ophthalmol2009353754219898625
  • YazganSCelikUAlagözNTaşMCorneal biomechanical comparison of pseudoexfoliation syndrome, pseudoexfoliative glaucoma and healthy subjectsCurr Eye Res201540547047524955822
  • BechmannMThielMJRoesenBUllrichSUlbigMWLudwigKCentral corneal thickness determined with optical coherence tomography in various types of glaucomaBr J Ophthalmol200084111233123711049946
  • KniestedtCLinSChoeJCorrelation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data: prospective analysis of biophysical parameters in tertiary glaucoma practice populationsJ Glaucoma2006152919716633220
  • TolesaKGessesseGWCentral corneal thickness in newly diagnosed glaucoma patients in South West Ethiopia: a cross-sectional studyBMC Ophthalmol201616115227580950
  • VenturaACBöhnkeMMojonDSCentral corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertensionBr J Ophthalmol200185779279511423450
  • ShahSChatterjeeAMathaiMRelationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinicOphthalmology1999106112154216010571352
  • OzkokATamcelikNOzdamarASariciAMCicikECorneal viscoelastic differences between pseudoexfoliative glaucoma and primary open-angle glaucomaJ Glaucoma201322974074524299728
  • HepsenIFYağciRKeskinUCorneal curvature and central corneal thickness in eyes with pseudoexfoliation syndromeCan J Ophthalmol200742567768017891195
  • European Glaucoma SocietyTerminology and Guidelines for Glaucoma3rd edSavona, ItalyDogma2008
  • GoldmannHSchmidTApplanation tonometryOphthalmologica19571344221242 German [with English abstract]13484216
  • EhlersNBramsenTSperlingSApplanation tonometry and central corneal thicknessActa Ophthalmol (Copenh)197553134431172910
  • WhitacreMMSteinRAHassaneinKThe effect of corneal thickness on applanation tonometryAm J Ophthalmol199311555925968488910
  • WolfsRCKlaverCCVingerlingJRGrobbeeDEHofmanAde JongPTDistribution of central corneal thickness and its association with intraocular pressure: The Rotterdam StudyAm J Ophthalmol199712367677729535620
  • DoughtyMJZamanMLHuman corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approachSurv Ophthalmol200044536740810734239
  • RahmanMLBunceCHealeyPRCommingling analyses of central corneal thickness and adjusted intraocular pressure in an older Australian populationInvest Ophthalmol Vis Sci20105152512251820071671
  • EysteinssonTJonassonFSasakiHReykjavik Eye Study GroupCentral corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye StudyActa Ophthalmol Scand2002801111511906297
  • InoueKOkugawaKOshikaTAmanoSMorphological study of corneal endothelium and corneal thickness in pseudoexfoliation syndromeJpn J Ophthalmol200347323523912782156
  • KuertenDPlangeNKochECKoutsonasAWalterPFuestMCentral corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCTGraefes Arch Clin Exp Ophthalmol201525371105110925896108
  • MukhopadhyayDRNorthRVHamilton-MaxwellKEEffect of a proparacaine 0.50%-sodium fluorescein 0.25% mix and contact ultrasound pachymetry on central and midperipheral corneal thickness measured by noncontact optical pachymetryJ Cataract Refract Surg201137590791321420274
  • MuscatSMcKayNParksSKempEKeatingDRepeatability and reproducibility of corneal thickness measurements by optical coherence tomographyInvest Ophthalmol Vis Sci20024361791179512036980
  • BechmannMThielMJNeubauerASCentral corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetryCornea2001201505411189004
  • WellsMWuNKokkinakisJSuttonGCorrelation of central corneal thickness measurements using Topcon TRK-1P, Zeiss Visante AS-OCT and DGH Pachmate 55 handheld ultrasonic pachymeterClin Exp Optom201396438538723336739
  • Garcia-MedinaJJGarcia-MedinaMGarcia-MaturanaCZanon-MorenoVPons-VazquezSPinazo-DuranMDComparative study of central corneal thickness using Fourier-domain optical coherence tomography versus ultrasound pachymetry in primary open-angle glaucomaCornea201332191322495027
  • AyalaMStrandåsRAccuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patientsBMC Ophthalmol20151512426420690
  • AdibelliFMOğuzHGöncüTYilmazOFYuksekyaylaFA comparison of central corneal thicknesses measured with two different methods in cases of primary open-angle glaucomaSemin Ophthalmol201613
  • HeijlABengtssonBHymanLLeskeMCEarly Manifest Glaucoma Trial GroupNatural history of open-angle glaucomaOphthalmology2009116122271227619854514