60
Views
10
CrossRef citations to date
0
Altmetric
Original Research

Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft

, , , , , & show all
Pages 1611-1615 | Published online: 01 Sep 2017

Abstract

Aim

Our study was conducted to evaluate whether higher temperature leads to increased – or wider – scroll widths of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft.

Purpose

To investigate the effects of temperature and fluid media on the DMEK donor graft scroll widths.

Materials and methods

This research work was a laboratory investigation. Baseline cell count was taken via specular microscopy for the donor corneas at room temperature (20°C–25°C). The endothelium sides of the donor corneas were stained with Trypan Blue Solution 0.4% for 30 s, and the Descemet’s membranes were stripped. The DMEK donor grafts were placed into three different fluid media – Optisol®, Balanced Salt Solution (BSS), and BSS PLUS® (BSS Plus). The DMEK donor grafts were then transferred into cold temperature (4°C) for 60 min, after which the donor grafts’ scroll widths were examined and measured. The donor grafts were then warmed in the incubator and brought to physiological temperature (35°C–37°C), and their scroll widths were examined and measured again.

Results

In 30 measurements of ten tissues across three temperature and fluid conditions, the average scroll width measured 1.73 mm, ranging from 1.1 to 2.9 mm. In a mixed linear model, the scroll widths increased with temperature (P=0.02). There was no significant difference in scroll widths among the three solutions (P=0.84, mixed linear model).

Conclusion

We observed an increase in DMEK donor graft scroll widths with higher temperatures. The usage of BSS Plus as media solution could also lead to smaller DMEK donor graft scroll widths, compared with BSS, but our study does not establish this.

Introduction

In the treatment of endothelial dystrophy, endothelial keratoplasty (EK) has largely replaced penetrating keratoplasty (PK).Citation1,Citation3 EK offers advantages of small incisional surgery, compared with PK – these include faster visual recovery, preservation of ocular structural integrity, and decreased overall induced astigmatism.Citation2 By 2014, Descemet stripping endothelial keratoplasty (DSEK) had become the most common (50%) type of corneal transplantation technique performed in the United States.Citation1

More recently, the Descemet’s membrane endothelial keratoplasty (DMEK) procedure has gained attention as a treatment type of EK. This is due to better visual acuity results in the first year after the DMEK surgery, compared to that typically reported for DSEK.Citation4 In addition, DMEK is associated with lesser refractive changes and similar endothelial cell counts when compared to DSEK.Citation4

Despite these promising results, DSEK remains the most common EK procedure.Citation1 The slower uptake in DMEK’s popularity has been attributed to current problems with DMEK, including the surgical challenges associated with manipulating the graft in the eye and higher rates of post-operative graft detachments.Citation4 One of the challenges of graft manipulation includes the unfolding of the DMEK donor graft scroll in the anterior chamber. As a tight scroll can present a technical challenge during surgery, we herein seek to identify media and temperature conditions that could influence donor graft scroll widths.

Materials and methods

Ethical statement: Ten human donor tissue grafts were collected from the Keralink International Eye Bank, USA, for research purposes, with a written consent from each donor’s next of kin. As our study used cadaveric donor tissues, the study was considered exempt from Institutional Review Board (IRB) review, per the University of Miami, Human Subject Office.

This study was a laboratory investigation. All of the DMEK grafts were “pre-stripped” and “pre-cut” by the same eye-bank technician within 48 h prior to the date of this study. The grafts were processed via the SCUBA (submerged cornea using backgrounds away) Descemet’s peeling technique with a 1–2 mm central attachment remaining. Grafts were then punched to 8 mm via Coronet trephine and placed into a Bausch & Lomb viewing chamber filled with Optisol-GS. The inclusion criteria for the DMEK grafts were 1) donors over 50 years of age and 2) without prior history of ocular surgery. We excluded all grafts below 50 years of age as well as grafts which tore during the “pre-stripping” or “pre-cutting” process. On the day of the study, the baseline cell count was taken via specular microscopy (Konan Medical, CellChek D+) for the donor corneas at room temperature (20°C–25°C).

The endothelium sides of the donor corneas were stained with Trypan Blue Solution 0.4%, for 30 s, and the “pre-cut” DMEK donor grafts were carefully stripped with the McPherson tying forceps via a one-touch technique. The DMEK donor grafts were randomly assigned to three different groups of fluid media – three donor grafts were placed in petri-dishes containing Optisol® (Chiron Ophthalmics, Irvine, CA, USA), four were placed in petri-dishes containing Balanced Salt Solution (BSS; Alcon Laboratories, Fort Worth, TX, USA), and the remaining three were placed in petri-dishes containing BSS PLUS® (BSS Plus; Alcon Laboratories). The donor grafts were placed in the fluid media immediately following stripping. The DMEK donor grafts were then transferred to a laboratory refrigerator (Jewett JBB1204A22; Thermo-Scientific, Waltham, MA, USA), which could constantly maintain a cold temperature of 4°C. The grafts remained in this cold environment for 60 min. This time-frame was chosen in order to fully equilibrate the temperature of the media solution holding our grafts, to 4°C.

At the end of the 60 min, the donor grafts’ scroll widths were examined and measured using ImageJ software (https://imagej.nih.gov), and using the measuring ruler placed underneath the petri-dish as a reference point (). The widest point of the scroll widths were measured. The donor grafts were then warmed in the laboratory incubator (Friocell 55; MMM Group, Munchen, Germany) and brought to physiological temperature (35°C–37°C). The influence of temperature and solution was assessed statistically with mixed linear models (SPSS Statistics version 22; IBM Corporation, Armonk, NY, USA) to account for multiple measurements made on the same corneas. One sample of each donor corneas was assigned to each of the three temperatures to balance effects of age, sex, and baseline endothelial cell count.

Figure 1 DMEK graft scroll width measurement. The DMEK donor graft is photographed free-floating in the petri-dish filled with media solution. The measuring ruler is used as a reference point.

Abbreviation: DMEK, Descemet’s membrane endothelial keratoplasty.
Figure 1 DMEK graft scroll width measurement. The DMEK donor graft is photographed free-floating in the petri-dish filled with media solution. The measuring ruler is used as a reference point.

Results

In 30 measurements of ten tissues () across three temperature and fluid conditions, the average scroll width measured 1.73 mm. The scroll widths ranged from 1.1 to 2.9 mm ().

Table 1 Donor graft characteristics

Table 2 Room temperature and scroll width

Table 3 Cold temperature and scroll width

Table 4 Warm temperature and scroll width

In a mixed linear model, scroll width size increased with temperature (P=0.023). Age, sex, and baseline endothelial cell count were balanced with respect to temperature and, therefore, do not confound this result; however, in a multiple linear regression model, none were statistically significantly related to scroll width (all P≥0.13). In our small sample, we had limited ability to assess the importance of using two corneas from the same donor (n=3); however, the intraclass correlation between the two eyes was 0.31 – that is, inclusion of right and left corneas from the same donor (n=3) did not appear to contribute substantively to a more similar scroll width size.

There average scroll widths were 1.80, 1.57, and 1.86 for Optisol, BSS plus, and BSS, respectively. There was no significant difference in scroll width among the three solutions (P=0.64, mixed linear model).

Discussion

The DMEK surgical procedure was formally introduced as a surgical technique from 2002 to 2006.Citation6Citation8 This was a consequence of the evolution of the posterior lamellar keratoplasty (PLK) techniques, wherein the key concept is to replace the corneal endothelium with a suture-less posterior lamellar graft via a small incision.Citation9Citation14

DMEK permits the transplantation of the Descemet’s membrane and endothelium, without the additional posterior stroma as with other PLK (including DSEK) procedures. This, in turn, translates into better visual acuity results in the first year after surgery than reported for DSEK.Citation4 The DMEK procedure was also found to have less postoperative refractive changes and similar endothelial cell counts when compared to DSEK.Citation4 In addition, DMEK had a significantly reduced rejection risk profile within 2 years after surgery, compared with DSEK and PK.Citation5

However, despite these advantages, DSEK is still the most common endothelial keratoplasty procedure.Citation1 The main challenge for the novice DMEK surgeon is the manipulation and the unfolding of the DMEK graft in the eye.Citation4 Guerra et al have noted that the DMEK donor grafts from young donors (<30 years) are more difficult to unfold, and younger donor tissues tend to scroll more tightly.Citation4 Grafts from donors younger than 55 years are usually thinner and show pronounced scrolling; this is because the posterior nonbanded layer of Descemet’s membrane gradually thickens with age.Citation15 For this reason, donor selection should exclude donors under 50 years because of tissue elasticity,Citation16 in order to avoid a tight scroll intraoperatively.

Keeping in mind this propensity of younger donor tissue for scrolling tightly, we used tissue from donors over 50 years of age (age range 51–69) for our study.

In regard to the finding of temperatures affecting scroll width size – we observed increased scroll widths with increased temperature (P=0.023). A “wider” scroll may translate into an easier and shorter surgery, as a tighter scroll demands more manipulation in order to “un-scroll” in the anterior chamber. This is of significant interest to the DMEK surgeon, especially the novice DMEK surgeon.

The storage media for the donor grafts had become a point of interest in the area of EK when Lee et al demonstrated that presoaking DSEK donor lenticules in BSS Plus reduces rates of DSEK graft detachment.Citation17 More recently, with increased interest in the preloaded DMEK graft,Citation18,Citation19 the question remains as to which is the optimal solution to store the DMEK donor grafts in the preloaded systems. Although BSS Plus had the smallest average scroll width, our study did not demonstrate a significant difference among the solutions (P=0.64). As aforementioned, a tight scroll poses a challenge intraoperatively, as it becomes more difficult to unfold. Our results suggest that, perhaps, the surgeon could consider avoiding BSS Plus when selecting a media agent to “pre-soak” the DMEK donor graft.

The main difference between BSS Plus and BSS is the presence of additional bicarbonate, phosphate, glucose, and glutathione. The pH of BSS Plus is 7.4, compared to 7.6 in BSS. The osmolality (mOsm) of BSS Plus is 305, compared to 298 for BSS. It is possible that the difference in pH or osmolality affects the scrolling behavior of the donor graft. Further studies would be warranted to elucidate the effects of pH and osmolality on scroll behavior.

The assignment of cornea samples to temperatures in our study was designed to eliminate the influence of donor characteristics on scroll width. Of the ten donor grafts, six of the donor grafts were pairs from three donors – that is, we obtained the right and left corneas from three donors. Our small study has very limited ability to assess the correlation of scroll widths between the two corneas of the same donor; however, we found that the right and left corneas from the same donor had a modest correlation of 0.31.

The main weakness of this study is the small sample size. However, the P-value finding (0.023) of the observation of increased scroll widths with increased temperature signifies that, despite the small sample size, the P-value supports the significance of this correlation between temperature and scroll width.

The DMEK technique continues to evolve, and this surgical technique offers the potential to give the fastest and most complete visual recovery for endothelial disorders.Citation20 The main finding of our study could potentially advance the DMEK technique – the increase in temperature effectively leads to a wider scroll width and, thus, would allow the DMEK surgeon to unfold the graft more easily.

Acknowledgments

This study was funded in part by the NIH Core Center Grant P30EY014801. KeraLink International provided donor tissue grafts and use of their facility for this study.

Disclosure

This scientific study was initiated by the principal investigators (Koo and Eghrari). The authors report no conflicts of interest in this work.

References