75
Views
11
CrossRef citations to date
0
Altmetric
Original Research

Intraoperative complications of refractive small incision lenticule extraction in the early learning curve

, &
Pages 665-668 | Published online: 09 Apr 2018

Abstract

Purpose

To study the intraoperative complications of refractive small incision lenticule extraction (ReSMILE push-up technique), and to record the mean intraoperative duration time of all surgeries for the refractive surgeon in his early learning curve.

Setting

Ebsar Eye Center, Benha, Egypt.

Design

A prospective, single-center, cohort clinical study.

Methods

This prospective, single-center, cohort clinical study was done on patients with myopia and myopic astigmatism, who were enrolled for SMILE surgeries. All the SMILE operations were performed by a single refractive surgeon (AMH), by using only the ReSMILE push-up technique.

Results

A total of 190 eyes were operated upon, using the (ReSMILE push-up technique), with a mean follow-up period of 2 months. The intraoperative complications have been recorded for all patients. The mean operative duration of all cases was 4.45±1.45 minutes.

Conclusion

The ReSMILE: push-up technique seems to facilitate visualization of the edge of the lenticule of the SMILE surgery, especially for the refractive surgeon in his early learning curve.

Background

Although the femtosecond laser has been used for over a decade to cut laser-assisted in situ keratomileusis (LASIK) corneal flaps with high precision, the evolution of small incision lenticule extraction (SMILE) has resulted in a paradigm shift in refractive surgery.Citation1Citation3

SMILE comprises the creation of a lenticule of corneal stroma using femtosecond laser, which is then extracted through a 2 mm incision. SMILE avoids all the flap complications associated with LASIK, including incomplete, irregular or thin flaps, button holes and free caps. In addition, it has been shown to preserve the strong anterior corneal lamellae, resulting in better long-term biomechanical stability as well as less postoperative dry eye due to the preservation of corneal nerve endings and thus faster and more comfortable visual recovery.Citation4,Citation5 SMILE is, therefore, a safe, predictable and efficacious method of refractive correction.Citation4,Citation6Citation8

The aim of this paper was to study the intraoperative complications of refractive small incision lenticule extraction (ReSMILE push-up technique) and to record the mean intraoperative duration time of all surgeries.Citation9 The ReSMILE push-up technique facilitates a crucial step of the surgery, which is dissection of the lenticule. We aimed at measuring the mean duration time of the ReSMILE push-up technique for the refractive surgeon in his early learning curve of SMILE.

Materials and methods

This prospective, single-center, cohort clinical study was done on patients with myopia and myopic astigmatism, who were enrolled for SMILE between January 1, 2017, and March 27, 2017, in Ebsar Eye Center, Benha, Qalyubia, Egypt. Our study was approved by the Research Ethics Committee of Benha Faculty of Medicine, Benha University.

Inclusion criteria were as follows: patients ≥18 years of age with no refractive change for at least 12 months, stable tear film and contact lens discontinuation for at least 2 weeks prior to surgery. Exclusion criteria included pachymetry readings <500 μm, corneal ectasias, eg, keratoconus, corneal opacities, ocular surface disease and severe dry eye syndrome.

All patients underwent uncorrected and best-corrected distance visual acuity, manifest and cycloplegic refraction, applanation tonometry, slit lamp examination, dilated fundus examination and Scheimpflug corneal tomography (OCULUS Pentacam®; OCULUS Inc., Wetzlar, Germany).

All the SMILE operations were performed by a single refractive surgeon (AMH), by using only the ReSMILE push-up technique. The nature of the procedure was explained to the patients, and written informed consent was obtained in accordance with the tenets of the Declaration of Helsinki.

After administration of topical anesthesia (benoxinate hydrochloride 0.4% eye drops), the eye was sterilized, draped and a speculum was inserted. Centration was achieved by asking the patient to fix on a flashing green target. Docking with the curved interface cone and suction fixation was applied. The femtosecond laser creates the deep surface of the lenticule in a spiral in fashion, the lenticule border, the superficial surface in a spiral out fashion and the small incision in that order. Suction was released, and the eye is undocked.

All SMILE operations were done using the VisuMax FS laser system (Carl Zeiss Meditec, Jena, Germany). We used the following femtosecond laser parameters: from 100 to 140 μm cap thickness, 7.5 mm anterior-plane cut diameter, 6.5 mm optical zone of lenticule and 160 nJ of energy with lenticule side-cut angles at 135°. A 3.0 mm entrance wound was created centered at 10:30 O’clock in all cases. The spot distance and tracking spacing were 4.5/4.5 μm for the posterior lenticule plane, 2.5/2.5 μm for the lenticule side-cut, 4.5/4.5 μm for the anterior lenticule plane and 2.5/2.5 μm for the entrance wound side-cut.

During the ReSMILE push-up technique, an instrument with a Y-shaped tip, the Bahr–Maltzman hook (0.8 mm delicate tip, 10 mm angle to tip and 118 mm overall length; ASICO, Westmont, IL, USA, product code: AE-2219), was inserted through the small incision catching the edge of the lenticule between the 2 ends of its tip. The caught edge of the lenticule is then pushed up from its bed, making it much easier to recognize inside the pocket ().Citation9 A spatula, the SMILE Double Ended Dissector with Spoon Tip (Duckworth and Kent, Hertfordshire, UK, Product Number: 6-836), is then passed below the pushed-up lenticule edge, dissecting a linear area resembling a tunnel below the middle of the deep surface of the lenticule, then passed above the pushed-up lenticule edge to dissect the lenticule from the cap and finally passed below the lenticule to dissect the remainder of the deep surface of the lenticule and fold it to one side. A non-toothed serrated micro-forceps, the smile lenticular removal forceps (Duckworth and Kent, Product Number: 2-836), is finally used to extract the lenticule.

Figure 1 Edge of lenticule caught by Y-shaped instrument.

Figure 1 Edge of lenticule caught by Y-shaped instrument.

Results

One hundred ninety eyes were operated on, using the ReSMILE push-up technique, with a mean follow-up period of 2 months. Thirty-five eyes presented with surgical complications (18.42%) (). They included: 1) Lost vacuum that occurred in 6 eyes (3.15%); in 4 eyes, the procedure was converted to Femtolasik, and in the other 2 eyes the treatment was continued as a SMILE using the same curved interface cone pack; 2) Treatment decentration in 2 eyes (1.05%) (), in whom the operations were aborted; 3) Wound bleeding occurred in 7 eyes (3.68%); 4) Bubbles in the interface occurred in 3 eyes (1.57%); 5) Incomplete bubble separation occurred in 1 eye (0.52%) (), which occurred due to Meibomian secretions adherence to the cone surface, in this case, the operation was aborted; 6) Epithelial defects occurred in 5 eyes (2.63%); 7) Incision tear occurred in 21 eyes (11.05%) (); and 8) Only 1 eye had cap rupture (0.52%) (). Lenticule adherence to the cap did not occur in any of our cases. The mean operative duration of all cases was 4.45±1.45 minutes.

Figure 2 ReSMILE intraoperative complications.

Notes: (A) Lenticule decentration. (B) Black island during the creation of the lenticule. (C) SMILE wound tear. (D) Cap rupture during dissection. Arrow shows the cap rupture during dissection.
Abbreviation: SMILE, small incision lenticule extraction.
Figure 2 ReSMILE intraoperative complications.

Table 1 Distribution of intraoperative SMILE complications

Discussion

Laser refractive surgery has been performed for many years, and there have been tremendous advancements in terms of technique and technology, making it increasingly precise and highly predictable.Citation10 Since the advent of SMILE, it has gained a reputation for being superior to LASIK regarding comfort and safety profile among surgeons and patients alike. This is largely due to avoidance of creation of a flap, thus avoidance of all flap-related complications of LASIK led SMILE to occupy an increasing share of our schedules as refractive surgeons.Citation11

As we became more familiar with the technique of SMILE, we came to notice that the most challenging step of the surgery was identification of the edge of the lenticule during dissection. We also noticed that most of the intraoperative complications of the surgery resulted from the surgeon’s inability to recognize the edge of the lenticule during his early learning curve. This forces the surgeon to keep trying to dissect under or above the lenticule for a long duration. These trials may lead to complications such as wound tear and cap or lenticule rupture, as well as longer operative duration time. Proper recognition of the edge of the lenticule should render the operation easy due to fast recognition of the lenticule with its under and upper surfaces, thus shortening the mean operative duration and minimizing intraoperative complications.Citation12

The ReSMILE push-up is a newly proposed technique () carried out using an instrument with a Y-shaped tip to “push-up” the edge of the lenticule from its bed prior to dissection, and hence, it becomes more easily recognizable.Citation9 The Y-shaped tip of the instrument is advantageous because it catches the edge of the lenticule easily between its 2 limbs (). The surgeon is now better guided to both planes of dissection superficial and deep to the lenticule by passing the dissecting spatula above or below the “pushed-up” edge of the lenticule that can be easily seen (after pushing-up) under the coaxial light of the microscope. This gives the surgeon more confidence regarding where his spatula is heading and prevents him tumbling inside the pocket trying to find the planes of dissection (possibly causing wound tears), dissecting the deep surface first (causing lenticule adherence to the cap) or dissecting into an entirely new plane (and having to abort the operation) and hence reducing the risk of intraoperative complications and mean operative duration time as well.

In this study, the “ReSMILE push-up technique” has resulted in a mean operative duration time of 4 minutes during the early learning curve for the refractive surgeon who is unfamiliar with both SMILE and ReSMILE techniques, implying a potential positive impact, in terms of patient comfort, improving the overall health care process and reducing the incidence of postoperative corneal haze as well.

Conclusion

Although SMILE is a promising refractive surgery for the correction of myopia and myopic astigmatism with predictable refractive and visual outcomes, complications can occur. Most of these complications are related to the learning curve of refractive surgeon that can be minimized by choosing the familiar technique among the different SMILE techniques. Based on our study we concluded that the ReSMILE push-up technique is safer for the refractive surgeons in their early learning curve. However, more research studies are required to evaluate this new ReSMILE push-up technique and to compare it to the SMILE conventional technique published in the literature.

Acknowledgments

The authors did not receive any financial support from any public or private sources and have no financial or proprietary interest in a product, method, or material described herein.

Disclosure

The authors report no conflicts of interest in this work.

References

  • SladeSGThe use of the femtosecond laser in the customization of corneal flaps in laser in situ keratomileusisCurr Opin Ophthalmol200718431431717568208
  • KimPSuttonGLRootmanDSApplications of the femtosecond laser in corneal refractive surgeryCurr Opin Ophthalmol2001224238244
  • ReinsteinDZArcherTJGobbeMSmall incision lenticule extraction (SMILE) history, fundamentals of a new refractive surgery technique and clinical outcomesEye Vis (Lond)20141326605350
  • ShahRShahSSenguptaSResults of small incision lenticule extraction: all-in-one femtosecond laser refractive surgeryJ Cataract Refract Surg201137112713721183108
  • WangYWuZTangXTwo millimeter micro incision lenticule extraction surgery with minimal invasion: a preliminary clinical reportZhonghua Yan Ke Za Zhi201450967168025533558
  • VestergaardAIvarsenARAspSHjortdalJØSmall-incision lenticule extraction for moderate to high myopia: predictability, safety, and patient satisfactionJ Cataract Refract Surg201238112003201022981612
  • SekundoWKunertKSBlumMSmall incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective studyBr J Ophthalmol201195333533920601657
  • MoshirfarMMcCaugheyMVReinsteinDZShahRSantiago-CabanLFenzlCRSmall-incision lenticule extractionJ Cataract Refract Surg201541365266525804585
  • HamedAFekryARefractive small-incision lenticule extraction: push-up and push-down techniquesJ Cataract Refract Surg201642121713171528007101
  • AlioJRefractive surgery today: is there innovation or stagnation?Eye Vision20141426605351
  • AngMTanDMehtaJSSmall incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority trialTrials2012137522647480
  • Ramirez-MirandaARamirez-LuquinTNavasAGraue-HernandezEORefractive lenticule extraction complicationsCornea201534suppl 10S65S6726226476