Abstract
Purpose
To assess the relationship between non-invasive tear break-up time (NITBUT) and maximum blink interval (MBI) values among young adults.
Method
The study was conducted at Mzuzu University and involved 98 subjects (55 females and 43 males) aged between 18 and 40 years. All subjects were screened under the slit lamp, and were also asked questions to determine their eligibility to participate in the study. NITBUT measurements were taken by checking the discontinuity of the mires on the keratometer. MBI measurements were taken by observing the time period the subject could keep their eyes open without blinking.
Results
There was a positive correlation (r=0.64, r2=0.418, P<0.001) between NITBUT and MBI values. The relationship between NITBUT and MBI values was similar in both males and females. Furthermore, the study showed that age, as well as gender, is not correlated to NITBUT and MBI values.
Conclusion
There is a positive significant correlation (r=0.64, r2=0.418, P<0.001) between NITBUT and MBI values. There was no significant difference between the NITBUT and MBI values between males and females. The study has also discovered that there is no correlation between NITBUT and MBI with age and gender.
Introduction
The National Dry Eye Workshop of 2007 defined dry eye as a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear film instability with potential damage to the ocular surface. It is accompanied by increased osmolality of the tear film and inflammation of the ocular surface.Citation1
Tear instability is considered a key factor in the mechanism of dry eye.
About 7–35% of the world’s population is said to have dry eye syndrome.Citation1 The large variability in the prevalence of dry eye is mainly due to differences in diagnostic tests and climatic differences. Despite its high prevalence, dry eye remains under-recognized in the clinic, due to insufficient data on some diagnostic techniques such as maximum blink interval (MBI) and non-invasive tear break-up time (NITBUT). MBI and NITBUT are non-invasive tear film stability tests which are clinically applicable, with minimal and cheap instrumentation required.Citation2
Dry eye patients experience symptoms such as burning sensation, dryness, tearing, and visual disturbances.Citation3–Citation5 The symptoms of dry eye can have adverse impacts on health, as well as reduce a person’s productivity. This is because dry eye can be problematic during activities such as reading, working on a computer, driving, and watching the television.Citation4 Furthermore, dry eye has been known to reduce corneal sensitivity, as well as predispose the cornea to infections, keratitis, and inflammation.Citation6–Citation8
The clinical diagnosis of dry eye is achieved by a battery of tests, which may include tear osmolality, Schimmer test, phenol red thread test, TBUT (tear break-up time), as well as the use of dry eye questionnaires. Needless to say, there is no single golden test for dry eye diagnosis, but rather a combination of tests is used in making a diagnosis.Citation9 The choice of the combination of tests depends on the availability of equipment, and differs from practitioner to practitioner.
Since tear film stability is considered the most important factor in the mechanism of dry eye, employing tests that will assess the tear film in the diagnosis of dry eye is considered precise and effective.Citation10 The aim of the study was to assess the relationship between NITBUT and MBI values, both of which are used to assess the tear film and are used in the diagnosis of dry eye. The results realized from the research can help in the diagnosis and possible management of dry eye by providing eye care professionals with readily available techniques.
Methodology
The study was conducted at Mzuzu University, located in Mzuzu city in the northern region of Malawi. The study targeted Mzuzu University students between 18 and 40 years of age. Based on a formula by Yamane,Citation11 a sample of 98 students was selected from the total population by using a stratified random sampling technique. The population was divided into stratum by faculty, and the student percentage distribution as per faculty was used to calculate the number of participants from each faculty. Subjects within each faculty were selected using a simple random sampling method to ensure accurate representation of the total population.
As an exclusion criteria, subjects were checked for conjunctivitis, a history of ocular surgery, lid abnormalities, current contact lens use, current use of eye drops, and contraceptive pills use.
The study was approved by the Faculty of Health Sciences Research Committee and the Mzuzu University Research Directorate. Permission to conduct the study at Mzuzu University was granted through the university registrar’s office.
All subjects were informed of the non-invasive nature of the procedures involved, as well as the benefits of the study, before signing a written consent form to participate in the study. The researcher maintained the anonymity of the participants; as such, the identity of the participants and their information remained confidential during and after the study. The participants were also informed that their participation was voluntary, and that they were free to withdraw at any point during the study.
Procedures
To measure for NITBUT, the subject was positioned on a well calibrated keratometer and three NITBUT readings were taken (using a stop watch) on the subjects’ right eye only, by noting the first sign of distortion of the mires after a complete blink.Citation12 The average of the three readings was considered the subjects’ NITBUT. This was done to reduce measuring errors incurred during such procedures. If the subject blinked before the distortion of the mires was noted, the procedure was stopped and the subject was allowed to blink several times before redoing the test.
To measure for MBI, the participant sat under normal conditions and was asked to blink and keep their eyes open for the longest time possible.Citation13 A stop watch was used to note the time from the last blink to when the subject could no longer keep their eyes open. The average of three consecutive readings was considered the subjects’ MBI. The subjects were not made aware that the MBI reading was being taken.
In order to minimize potential bias due to the subjective nature of the tests, the data were collected by three different investigators. An average of three measurements from each investigator was considered the final reading of the test.
Results
The statistical analysis was performed using SPSS 16.0. The correlations between the NITBUT and MBI values were analyzed using Pearson’s r correlation test. Bar graphs were used to graphically illustrate descriptive statistics.
The study employed a sample size of 98 participants, which included 55 females and 43 males. The participants’ age ranged from 18 to 40 years. MBI values ranged from 9 to 33 s, with mean of 21 s (SD=5.99 s). NITBUT values ranged from 6 to 23 s, with a mean of 16 s (SD=3.55 s).
Relationship between NITBUT and MBI values
There was a significant positive correlation (r=0.6, r2=0.418, P<0.001) between NITBUT and MBI values, as illustrated in . There was no significant difference in the NITBUT and MBI values between genders (t(96)=0.4, P=0.629). That is, there was a positive correlation between NITBUT and MBI values among males (r=0.6, n=43) and females (r=0.6, n=55).
Distribution of NITBUT and MBI values according to age
The results of our study show that there was no correlation between MBI values and age (P=0.805), as well as NIT-BUT and age (P=0.641), as illustrated in and , respectively.
Distribution of MBI values according to gender
An independent sample t-test was conducted to compare the mean of MBI values between males and females. The average of MBI values among males and females was equal. Males had a mean MBI value of 21 s (SD=6.01 s), and females registered a mean MBI value of 21 s (SD=6.01 s); t(96)=0.4, P=0.629.
Distribution of NITBUT values according to gender
The average NITBUT values observed among female and male subjects were equal. Male subjects had an average NITBUT value of 16 s (SD=3.02 s), and female subjects had an average NITBUT value of 16 s (SD=3.29 s). shows the distribution NITBUT values according to gender.
Discussion
Relationship between NITBUT and MBI values
Our study found that there is a significant correlation (r=0.6, r2=0.418, P<0.001) between NITBUT and MBI values, which is in agreement with Glasson et al,Citation14 who found a significant correlation between the two variables at the University of New South Wales. The results of our study are also similar to a study by Liu et al,Citation15 although they used invasive TBUT. Liu et alCitation15 presented a significant correlation between TBUT and MBI values.
This study indicates that the relationship between NIT-BUT and MBI values in Malawi, Africa, is the same as in other parts of the world, with different climatic conditions. This is in contrast with Patel et al,Citation16 who suggested that TBUT findings may vary across different climatic conditions as well as geographical settings. Therefore, with regard to different climatic conditions in different environments, the relationship between NITBUT and MBI values is the same as evidenced by similar findings of studies conducted in different continents with different climatic conditions.
Distribution of NITBUT and MBI values according to age
Our study results showed that there was no correlation between age and MBI values, and also between age and NITBUT values. This is in agreement with Amaechi and Osunwoke,Citation17 who reported that there is no correlation between age and the tear film stability. However, other authorsCitation2,Citation18 reported a negative correlation between age and NITBUT. The differences in correlations between the tear film stability and age may be due to differences in the age groups used among different studies.
For instance, this study, and the study by Amaechi and Osunwoke,Citation17 employed a narrow range of age. Our study included subjects ranging from 18 to 40 years, and Amaechi and OsunwokeCitation17 recruited subjects ranging from 20 to 30 years, while Ozdemir and TemizdemirCitation18 included subjects with a wide age range (20–80 years).
Our study reports no correlation between age and NIT-BUT/MBI, and this could be because the study had employed a narrow age range (18–40 years), hence there would be little aging effects of dry eye seen.
Distribution of NITBUT and MBI values according to gender
The study results showed that there is no differences between NITBUT and MBI values with respect to gender. A similar trend of NITBUT and MBI values was observed in both males and females in studies by Mishra et al,Citation19 Yee et al,Citation2 and Ozdemir and Temizdemir.Citation18 This signifies that there is no tear film difference with respect to gender.
However, results of this study differ from a study by Maissa and Guillon,Citation20 who noted that there are lower NITBUT values among females under the age of 45 years as compared to males. They further reported that, beyond the age of 45 years, the average NITBUT values for both genders were equal.
Conclusion
This study had investigated the relationship between NITBUT and MBI values among young adults at Mzuzu University. The study results showed a positive significant correlation (r=0.6, r2=0.418, P<0.001) between NITBUT and MBI values. It has also been discovered that the relationship between NITBUT and MBI values is equal among males and females. The study has also discovered that there is no correlation of NITBUT and MBI values with age and gender.
Disclosure
The authors report no conflicts of interest in this work.
References
- Dry Eye WorkshopThe definition and classification of dry eye disease: report of the Definition and Classification Subcommittee of the International Dry Eye WorkShop (2007)Ocul Surf20075759217508116
- Sharanjeet-KaurHoCYMutalibHAGhazaliARThe relationship between tear ferning patterns and non-invasive tear break-up time in normal Asian populationJ Optom2016917518126652245
- GaytonJLEtiology, prevalence, and treatment of dry eye diseaseClin Ophthalmol2009340541219688028
- MiljanovićBDanaRSullivanDASchaumbergDAImpact of dry eye syndrome on vision-related quality of lifeAm J Ophthalmol200714340941517317388
- LeQZhouXGeLWuLHongJXuJImpact of dry eye syndrome on vision-related quality of life in a non-clinic-based general populationBMC Ophthalmol2012122222799274
- NgALToKKChoiCCPredisposing factors, microbial characteristics, and clinical outcome of microbial keratitis in a tertiary centre in Hong Kong: a 10-year experienceJ Ophthalmol2015201576943626167295
- XuKPYagiYTsubotaKDecrease in corneal sensitivity and change in tear function in dry eyeCornea1996152352398713924
- HauswirthSGWhen dry eye compromises corneal integrityReview of Optometry website2017 Available from: https://www.reviewofop-tometry.com/article/ro1117-when-dry-eye-compromises-corneal-integrity#footnotesAccessed April 8, 2018
- HendersonRMaddenLDry-eye managementOptom Pract201314137146
- SweeneyDFMillarTJRajuSRTear film stability: a reviewExp Eye Res2013117283823973716
- YamaneTStatistics: an introductory analysis2nd edNew YorkHarper and Row1967
- TerryRWilliamsLToitRDiagnosis & management of dry eye in contact lens wearAustraliaThe International Association of Contact Lens Educators1997 Available from: https://www.iacle.org/index.php?option=com_content&view=article&id=322Accessed July 13, 2018
- NakamoriKOdawaraMNakajimaTMizutaniTTsubotaKBlinking is controlled primarily by ocular surface conditionsAm J Ophthalmol199712424309222228
- GlassonMJStapletonFKeayLSweeneyDWillcoxMDDifferences in clinical parameters and tear film of tolerant and intolerant contact lens wearersInvest Ophthalmol Vis Sci2003445116512414638706
- LiuHBegleyCGChalmersRWilsonGSrinivasSPWilkinsonJPTemporal progression and spatial repeatability of tear breakupOptom Vis Sci20068372373017041317
- PatelSVirhiaSKFarrellPStability of the precorneal tear film in Chinese, African, Indian, and caucasian eyesOptom Vis Sci1995729119158749340
- AmaechiOUOsunwokeCMThe relation between invasive and noninvasive tear break-up time in young adultsJ Niger Optom Assoc2004112932
- OzdemirMTemizdemirHAge- and gender-related tear function changes in normal populationEye201024798319229268
- MishraPSrivastavaDMisraRMalikVKTrivediVAssessment of tear secretions in healthy Indian volunteersIndian J Physiol Pharmacol20145813714025509963
- MaissaCGuillonMTearfilm dynamics and lipid layer characteristics – effect of age and genderCont Lens Anterior Eye20103317618220202891