Introduction

Hemorrhage is a serious complication following percutaneous biopsy requiring detecting and immediate treatment of active bleeding. This study aimed to explore the potential benefits of ultrasound (US)-guided microwave ablation (MWA) to treat acute hemorrhage in risky locations.

Materials and methods

We present seven patients (four males and three females) aged 19–69 years with solid-organ arterial hemorrhage treated by US-guided MWA and followed up with contrast-enhanced US (CEUS).

Results

All seven cases successfully underwent MWA for hemostasis, and their vital signs subsequently stabilized. During the follow-up from 13 to 36 days, the ablation area decreased slowly in five patients and was still stable in two cases. There were no complications observed in this study after MWA treatment. We also reviewed a total of 12 publications in the past 10 years.

Conclusion

This study suggested that US-guided MWA may be an effective and safe strategy for acute hemorrhage in the emergency setting. To confirm this method and benefit more patients, more prospective studies with larger samples and longer follow-ups are recommended.

Background

Percutaneous biopsy is the main diagnostic method of tissue tumors. Although more and larger size biopsy specimens have enabled more reliable pathology results, it has increased the risk of hemorrhage from arterial sources,Citation1,Citation2 which requires detecting and immediate action against massive active bleeding. Traditional hemostasis methods, such as surgical practice with clamping, suturing,Citation3,Citation4 or removing the bleeding parts of the organs, have been performed, which occasionally fail due to central artery rupture, suture-induced tissue infarction, and pseudoaneurysm formationCitation5 and thus add to the total expenditure. Another common technology is transcatheter angiographic embolization (TAE),Citation6 although the radiation may be hazardous and cause severe complicationsCitation7 and might not be easily accessible and available. Compared to these approaches, thermal ablation – particularly microwave ablation (MWA) – would ablate bleeding vessels under color Doppler flow imaging (CDFI) or contrast-enhanced ultrasound (CEUS), reaching the target tissue and causing faster and larger-scale irreversible tissue coagulation and necrosis in the treated region. MWA has been mainly used in the treatment of active hemorrhage of livers, and its feasibility has been confirmed in both animal studies and clinical practice.Citation8Citation10 However, few publications have reported MWA for bleeding in greater risk locations such as the thyroid, spleen, and thoracic wall. This study aimed to summarize the potential benefits of US-guided MWA to treat acute hemorrhage and to preliminarily evaluate its therapeutic effect.

Case series

We prospectively included seven patients (four males and three females) aged 19–69 years, whose main complication was solid-organ hemorrhage caused by biopsy, interventional operation, or trauma from December 2013 to September 2016. This clinical trial was registered in ClinicalTrials.gov ID: NCT3026452, and the procedure was approved by the ethics committee of The First Affiliated Hospital of Zhejiang University. All patients signed written informed consents and were informed of the risk and advantages of MWA for hemostasis. The baseline of these cases in the study is summarized in . Eligible patients met the following criteria: (1) ultrasound (US) clearly found arterial bleeding, bleeding spots with velocity >100 cm/s; (2) US detected hematoma, along with continuous fall of hemoglobin (Hb) and blood pressure levels; (3) the bleeding position was deep, and the 5-min surface pressure for hemostasis was invalid if bleeding velocity was <100 cm/s. Among these seven cases, hemorrhages appeared in two cases caused by spleen biopsy (), liver biopsy (), or percutaneous transhepatic cholangial drainage (PTCD). In two cases, hemorrhages had been induced by thyroid biopsy (), and one resulted from trauma in the thoracic wall (). The mean of Hb, heart rate (HR), and velocity in these cases was 111.7 ± 35.0 g/L, 98.9 ± 16.3 beats/min, and 88 ± 18.5 cm/s, respectively. Furthermore, CEUS successfully detected the hemorrhages, and free fluid was available in all cases, which contributed to the location of the bleeding with US and hematoma.

Table 1 The basic characteristics of patient with hemorrhage

Figure 1 (A) Crescent-shaped hematoma around the spleen as detected by sonography (arrowheads). (B) Enhanced hemorrhage of puncture tract on contrast-enhanced ultrasound (CEUS). (C) Ultrasound (US)-guided microwave electrode was set into the hemorrhage region (arrowhead). (D) After ablation, enhancement was not detected in the ablation zone (arrowheads).

Figure 1 (A) Crescent-shaped hematoma around the spleen as detected by sonography (arrowheads). (B) Enhanced hemorrhage of puncture tract on contrast-enhanced ultrasound (CEUS). (C) Ultrasound (US)-guided microwave electrode was set into the hemorrhage region (arrowhead). (D) After ablation, enhancement was not detected in the ablation zone (arrowheads).

Figure 2 (A and B) Active bleeding originated from the puncture tract with a velocity of 1.13 m/s (arrowheads). (C) A 1.3 cm crescent-shaped free fluid was detected by sonography around the liver (arrowheads). (D) After microwave ablation, contrast-enhanced sonography did not show any microbubble extravasation inside the liver (arrowheads).

Figure 2 (A and B) Active bleeding originated from the puncture tract with a velocity of 1.13 m/s (arrowheads). (C) A 1.3 cm crescent-shaped free fluid was detected by sonography around the liver (arrowheads). (D) After microwave ablation, contrast-enhanced sonography did not show any microbubble extravasation inside the liver (arrowheads).

Figure 3 (A) Active bleeding lesion was detected along with small bleeding vessels leaking to the thyroid surface (arrowhead). (B) Contrast-enhanced sonography showed an irregular hematoma measuring 2.6×1.6 cm around the right thyroid (arrowheads). (C and D) Irregular hematoma was detected around the right thyroid, and ablation region showed no enhancement on contrast-enhanced sonography (arrowheads).

Figure 3 (A) Active bleeding lesion was detected along with small bleeding vessels leaking to the thyroid surface (arrowhead). (B) Contrast-enhanced sonography showed an irregular hematoma measuring 2.6×1.6 cm around the right thyroid (arrowheads). (C and D) Irregular hematoma was detected around the right thyroid, and ablation region showed no enhancement on contrast-enhanced sonography (arrowheads).

Figure 4 (A and B) Active bleeding originated from a branch of thoracic wall artery (arrowheads). (C) Ultrasound (US)-guided microwave ablation (MWA) (arrowhead). (D) Visible microbubbles extravasation was not observed in this section of hemostasis.

Figure 4 (A and B) Active bleeding originated from a branch of thoracic wall artery (arrowheads). (C) Ultrasound (US)-guided microwave ablation (MWA) (arrowhead). (D) Visible microbubbles extravasation was not observed in this section of hemostasis.

All patients received conservative therapies such as real-time monitoring under US, local pressing with US probe, or US-guided injection of hemostatic drugs into hemorrhage regions. However, improvement was not observed. One patient, whose Hb declined continuously following spleen biopsy, was in shock, and her vital signs were unstable. Two other patients with thyroid biopsies to obtain pathologic diagnosis experienced uncontrollable bleeding even after pressing the puncture point for 30 min.

Under sonographic guidance, we selected CDFI patterns to observe active bleeding and to estimate its velocity by pulse wave (PW). When active bleeding velocity was faster than 100 cm/s, MWA was considered. CEUS was performed to locate the target area before MWA. Then a 15-gauge microwave electrode was inserted into the bleeding sites, which were ablated by the output power of 50–100 W with 2,450 MHz for 6–8 min using ECO (ECO Medical, Nanjing, China). During the procedure, the electrode was retracted by 1.5–2 cm to ablate small leaking vessels during ablation. The results depended on the microwave frequency and whether treated tissues were coagulated. The hemostatic effect gradually increased with increasing power until carbonized tissues prevented heat conduction.

To estimate the effects of MWA for hemostasis, CEUS was performed immediately using SonoVue (Bracco SpA, Milan, Italy) after interventional therapy. Successful hemostatic criteria were as follows: first, the hyperechoic area would overlay the entire lesions, and enhancement was not observed in the ablation zones under CEUS. Extravasation of the contrast agent was also not detected around the target organs or tissue spaces. Finally, all vital signs including decreased HR that was within the normal range and elevated blood pressure subsequently stabilized. Hemostasis failure was considered when CEUS showed microbubble extravasation in the trauma regions after ablation, or when the electrocardiogram (ECG) monitor showed unstable blood pressure and HR. When hemostasis was unsuccessful after the first treatment, a second ablation was performed immediately. When interventional hemostasis therapy had not been available after three attempts, open surgery was required immediately.

Results

presents the detailed procedures and outcomes of US-guided ablation for each case. During the procedures, increased temperature made the bleeding coagulated, and the bleeding speed reduced. Then tissues around the electrodes were coagulated slowly, and there was no abnormally fast blood flow around the bleeding spot, indicating that hemostasis was successfully available. After MWA, enhancement was not detected in the ablation zone (, , , and ).

Table 2 The detailed description in the procedures of microwave ablation (MWA) for hemostasis

Patients’ blood pressure rose gradually to the normal after MWA and became stable. During the follow-up of 13 to 36 days, the ablation area decreased slowly in five patients and was still stable in two cases. There were no complications observed in this study after MWA treatment.

In addition, we reviewed a total of 12 publications from PubMed, Scopus, and Web of Science before April 2017 documenting thermal ablation for hemostasis following biopsy or surgical resection ().Citation11Citation22 In the literature review, nine studies reported the efficacy of MWA/radiofrequency ablation (RFA)/percutaneous ethanol injection (PEI) on 22 patients (aged 29–83 years, five males and 17 females) with solid-organ bleeding from uterine, liver, and spleen. They suggested 90.9% efficiency rate without major complications.

Table 3 Summary of 12 published literatures about hemostasis in animal and clinical experiments

Discussion

Solid-organ hemorrhage deriving from trauma is a serious condition requiring immediate diagnosis and treatment. In our hospital, US-guided tissue biopsy, which involves various solid organs such as thyroid, breast, prostate, liver and spleen, was performed in ~3,000 cases every year. The number of thermal ablation treatments for solid-organ tumors increased to 720 last year. With such a huge amount of interventional operations, the occurrence of various complications like hemorrhage is inevitable, amounting tô0.7% (0.4% slight bleeding using surface pressure for hemostasis and 0.3% severe bleeding by MWA against solid-organ hemorrhage).

Baseline sonography is not sensitive to guide the insertion of ablation needles in the treatment of abdominal solid organ injury. Sonography is a reliable screening tool for detecting active bleeding in combination with CDFI pattern, particularly with the presence of continuous free fluid in the abdominal cavity or hematoma in the tissue space. In particular, CEUS could show real-time and contrast-related images via microbubbles produced, and CEUS was clearer in detecting hemorrhagic spots and assessing the degree of damage.Citation23Citation25 Several studies showed that CEUS is a potential tool that is nearly as sensitive as contrast-enhanced-computed tomography (ceCT) for the detection of traumatic abdominal organ injuries.Citation26,Citation27 Moreover, the proposed method has no radiation hazard and is a safer contrast agent compared to ceCT.

Previous studies showed that RFA decreased blood loss in hepatectomy both in animal and clinical experiences.Citation28 The temperature in RFA increased slowly, and heat was easily taken away by vessels. Thus, it could not reach the target temperature, and the limited coagulation zone size was an important issue in RFA.Citation11 Compared with RFA, MWA depended less on tissue impedance and has a larger zone of active heating.Citation19,Citation29 MWA enabled the microwave antenna in the targeting tissue to locally obtain an average temperature of 65°C–100°C in seconds, resulting in its coagulation necrosis, which made it possible to quickly achieve hemostasis and lower the cost without any radiation hazard and major complications from TAE.Citation7 Additionally, contrast agent in angiography may increase the metabolic burden of liver and kidney while contrast agent in CEUS not due to its pulmonary pathway for discharge. Some studies also demonstrated that modified MWA has a larger ablative range and higher top temperatures than the previous one because of their longer wavelength, deeper penetration depth, and lower energy attenuation.Citation30,Citation31 Thus, MWA was useful for controlling life-threatening hemorrhages even when active bleeding occurred in a larger diameter vessel.

The main limitation of this study was its small sample size and the short-term follow-up, which may have impact on the delayed bleeding if possible. The existing heat-sink in MWA may limit tissue heating and tissue ablation.

Conclusion

US-guided percutaneous MWA may be an effective and safe strategy for hemostasis in patients with hemorrhage in the emergency setting. To verify this method and benefit more patients, more prospective studies with larger samples and longer follow-ups are needed.

Acknowledgments

This study was supported by the opening foundation of the State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital of Medical College, Zhejiang University, grant No 2015KF06. This study was also supported by the Foundation of Zhejiang Health Committee, grant No 2017KY346.

Disclosure

The authors report no conflicts of interest in this work.

References

  • RabeeaASiddiquiABRizwan KhanMTSunderSWaqarKBleeding complications post ultrasound guided renal biopsy – a single centre experience from PakistanAnn Med Surg2017218588
  • SandrasegaranKThayalanNThavanesanRRisk factors for bleeding after liver biopsyAbdom Radiol2016414643649
  • BartonJKPopokDPBlackJFThermal analysis of blood undergoing laser photocoagulationIEEE J Sel Top Quantum Electron200176936943
  • NguyenVPKimJHaKLOhJKangHWFeasibility study on photoacoustic guidance for high-intensity focused ultrasound-induced hemostasisJ Biomed Opt2014191010501025354118
  • ZhangGSunYYuJMicrowave coagulation therapy and drug injection to treat splenic injuryJ Surg Res2014186122623323992856
  • ZentaiCGrottkeOSpahnDRRossaintRNonsurgical techniques to control massive bleedingAnesthesiol Clin2013311415323351533
  • LetoublonCMorraIChenYMonninVVoirinDArvieuxCHepatic arterial embolization in the management of blunt hepatic trauma: indications and complicationsJ Trauma20117051032103621610421
  • SongHPYuMZhangJHemostasis of active bleeding from the liver with percutaneous microwave coagulation therapy under contrast-enhanced ultrasonographic guidance: an experimental studyJ Ultrasound Med200827686787418499846
  • ValentinoMSerraCZironiGDe LucaCPavlicaPBaroxxiLBlunt abdominal trauma: emergency contrast-enhanced sonography for detection of solid organ injuriesAm J Roentgenol201218613611367
  • YanarHErtekinCTavilogluKKabayBBakkalogluHGulogluRNonoperative treatment of multiple intra-abdominal solid organ injury after blunt abdominal traumaJ Trauma200864494394818404060
  • YekuoLShashaWFengHMultipolar radiofrequency ablation in controlling hemorrhage from blunt liver traumaAm J Emerg Med200927219720119371528
  • SunYZhangGDongLStudy of percutaneous coagulation therapy of 915 MHz microwave for the renal artery injury guided by contrast ultrasound in vivo dogsChin J Clin2013221464436447 Available from: http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=zhlcyszz201314053#Accessed February 28, 2018 Chinese
  • BinXNingmingZWeitianCExperimental study of ultrasound-guided cold circulation microwave ablation in treating splenic traumaChn J Ultra Med20143016971 Available from: http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=zgcsyxzz201401022Accessed February 28, 2018 Chinese
  • AytekinCYildirimUMOzyerUHarmanHBoyvatFEmergency renal ablation for life-threatening hemorrhage from multiple capsular branches during renal artery stentingCardiovasc Intervent Radiol20103366366619957179
  • ChapaHOAntonettiAGSandateJSilverLEmergent thermal balloon ablation for acute uterine hemorrhage: a report of 2 casesJ Reprod Med20105551151321291039
  • NakayamaKRahmanMTRahmanMMicrowave endometrial ablation is a highly efficacious way to emergently control life-threatening uterine hemorrhageArch Gynecol Obstet201128351065106820464408
  • MaroulisISpyropoulosCKalogeropoulouCKaraviasDUse of radiofrequency ablation for controlling liver hemorrhage in the emergency setting; report of two cases and review of the literatureTurk J Trauma Emerg Surg2013192167172
  • WeigtJKandulskiAMalfertheinerPEndoscopic intraductal radiofrequency ablation of remnant intrapapillary mucinous neoplasm with acute hemorrhage after incomplete surgical resectionEndoscopy201446S 01E489E49025314212
  • ZhouLKuangMXuZXieXLuMContrast-enhanced sonographically guided thermal ablation for treatment of solid-organ hemorrhage preliminary clinical resultsJ Ultrasound Med20153490791525911724
  • OguraTTakagiWUenoSTakeuchiTFukunishiSHiguchiKEndoscopic hemostasis for tumor bleeding using intraductal radiofrequency ablationEndoscopy201648S 01E328E32927741528
  • WaiOKNgLFYuPSChanJCPost biopsy liver hemorrhage successfully controlled by ultrasound-guided percutaneous microwave ablationJ Clin Imaging Sci201663427833776
  • PopeMCBallardDHStickerALAhujaCD’AgostinoHBEthanol ablation in postbiopsy liver hemorrhage following two failed embolizationsClin Imaging201640115616026454615
  • TangJLvFLiWContrast-enhanced sonographic guidance for local injection of a hemostatic agent for management of blunt hepatic hemorrhage: a canine studyAm J Roentgenol20081913W107W11118716077
  • ValentinoMSerraCPavlicaPBarozziLContrast-enhanced ultrasound for blunt abdominal traumaSemin Ultrasound CT MR200728213014017432767
  • ZhangGDongLTaiYContrast-enhanced sonographically guided percutaneous 915-mhz microwave ablation therapy compared to local hemostatic drug injection in a renal artery injury modelJ Ultrasound Med201433461162124658940
  • ThoreliusLEmergency real-time contrast-enhanced ultrasonography for detection of solid organ injuriesEur Radiol200717 Suppl 66F107F11118376464
  • ValentinoMSerraCPavlicaPBlunt abdominal trauma: diagnostic performance of contrast-enhanced US in children – initial experienceRadiology2008246390390918195385
  • PengYMorrisDLRadiofrequency ablation-assisted liver resection: review of the literature and our experienceHPB (Oxford)20068424825418333135
  • KontosMFelekourasEDrakosERadiofrequency tissue ablation in an experimental model of grade IV renal trauma: a preliminary reportSurg Endosc200519224925315529190
  • SunYChengZDongLZhangGWangYLiangPComparison of temperature curve and ablation zone between 915- and 2450-MHz cooled-shaft microwave antenna: results in ex vivo porcine liversEur J Radiol201281355355721354733
  • WangYSunYFengLGaoYNiXLiangPInternally cooled antenna for microwave ablation: results in ex vivo and in vivo porcine liversEur J Radiol200867235736117768024