Latency and Loss of Pulse Oximetry Signal with the Use of Digital Probes during Prehospital Rapid-Sequence Intubation

, MD, , MD, , BS, & , BS
Pages 18-22 | Received 25 Feb 2010, Accepted 02 May 2010, Published online: 16 Feb 2011
 

Abstract

Background. Prehospital personnel rely on timely and accurate pulse oximetry data when performing critical skills, such as rapid-sequence intubation (RSI). However, loss of signal may be a frequent occurrence in patients with poor peripheral perfusion. In addition, a delay or latency period in the timeliness of pulse oximetry data may exist with probes placed on the fingers. Objective. To define the incidence of pulse oximetry signal loss or a latent period during prehospital RSI. Methods. Patients with severe traumatic brain injury (TBI) (Glasgow Coma Scale score [[GCS]] 3–8) undergoing prehospital RSI by air medical crews were enrolled. Data from hand-held oximetry–capnometry units were analyzed for either the loss of a pulse oximetry tracing (≥ 30 seconds) during the RSI procedure or the presence of a latent period, defined by the saturation of peripheral oxygen (SpO2) nadir occurring after intubation in patients undergoing desaturation (SpO2 ≤ 93%%) during the procedure. Results. A total of 98 of 124 patients (79%%, 95%% confidence interval [[CI]] 71–85%%) had pulse oximetry failure during critical points in the RSI procedure. In the 49 patients with a desaturation during RSI, a latent period was observed in 27 patients (55%%, 95%% CI 41–68%%). Conclusions. A high incidence of pulse oximetry failure was observed with the use of a digital pulse oximetry probe during prehospital RSI. In addition, a latent period appears to exist in the majority of patients undergoing desaturation.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 85.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.