Effect of Temperature and Humidity on Formaldehyde Emissions in Temporary Housing Units

, , &
Pages 689-695 | Published online: 10 Oct 2011

ABSTRACT

The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S. Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. On the basis of a previous study, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high-performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using the natural log of the percent relative humidity (RH) and inverse of temperature (in K) as independent variables and the natural log of emission factors as the dependent variable. The coefficients for the inverse of temperature and log RH with log emission factor were found to be statistically significant for all of the samples at the 95% confidence level. This study should assist in retrospectively estimating indoor formaldehyde exposure of occupants of THUs.

IMPLICATIONS

Maddalena et al. reported differences between formalde-hyde concentrations in samples collected from the THUs during the morning and afternoon of the same day, highlighting the need to carry out further analysis on the effect of temperature and humidity on formaldehyde emissions. This study addresses the influence of temperature and humidity on formaldehyde emission factors from individual materials. The information provided can be incorporated into an exposure assessment study for the occupants of the FEMA trailers. However, because the experiments are carried out only on four samples from the THUs, they might not be representative of the entire fleet of THUs.

INTRODUCTION

This study is part of a larger effort to retrospectively estimate indoor formaldehyde exposures of the occupants of temporary housing units (THUs). The U.S. Federal Emergency Management Administration (FEMA) supplied over 100,000 emergency THUs to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. Concerns about the indoor environmental quality in the THUs emerged based on occupant health complaints and concerns. The U.S. Environmental Protection Agency (EPA)Citation1 reports that various studiesCitation2–4 have shown that acute exposure to formaldehyde can cause irritation in the eyes, nose, and throat. Human studiesCitation5,Citation6 have reported increased levels of respiratory illnesses because of chronic formaldehyde exposure. Numerous studiesCitation7,Citation8 showed that chronic exposure to form-aldehyde caused increased cancer incidence in rodents. Some human studiesCitation9,Citation10 have also reported higher rates of respiratory-site cancer occurrence among subjects regularly exposed to high formaldehyde levels. Formaldehyde is currently classified as a probable human carcinogen by EPA.Citation11 Measurements reportedCitation12,Citation13 showed that formalde-hyde concentrations observed in occupied and unoccupied THUs exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit (REL) of 0.016 parts per million (ppm),Citation14 often by a factor of 10 or greater. The NIOSH REL was based on the analytical limit of detection and not on health effects data.

In the THUs, sources contributing to elevated indoor formaldehyde concentrations were related to building materials and furnishings. Maddalena et al.Citation15,Citation16 measured the indoor concentration and whole trailer emission factors in four unoccupied THUs for a range of volatile organic compounds (VOCs) and aldehydes. The study also determined the material-specific emission factors of the compounds from individual surface materials collected directly from the THUs. It was observed that all THUs had a significant portion of the internal surface area constructed with ⅛-in. plywood with a vinyl or polyvinyl chloride skin or simulated wood finish. All units had sheet vinyl flooring, and two of the four trailers also had carpeted areas. All countertops were particle-board surfaced with high-pressure laminate. Various wood products were used for the subfloor and for the bench and bed platforms. Formaldehyde was observed to be the only aldehyde emitted from these materials at rates sufficient to be of health concern. A range of VOCs typically present when formal-dehyde is observedCitation17 are also emitted from materials. Like formaldehyde, which is a toxic air contaminant,Citation1,Citation18 many of the VOCs are known to have low odor thresholds, high potency as respiratory irritants, and in some cases carcinogenicity. On the basis of the previous study,Citation15,Citation16 the surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. As detailed by Hawthorne et al.Citation19 the mechanism of formaldehyde emissions depends on the production of formaldehyde in the bulk material, the transport through the bulk material, and the transfer of formaldehyde out of the bulk material and into the atmosphere. A few key studies have been carried out to measure the effect of temperature and relative humidity (RH) on formaldehyde emissions. Zhang et al.Citation20 conducted chamber experiments to understand the influence of temperature on the partition coefficient and diffusion coefficient and found that the partition coefficient decreases with an increase in temperature, and the diffusion coefficient increased with an increase in temperature. However, the equilibrium concentration of formal-dehyde increased with an increase in temperature. Andersen et al.Citation21 conducted field and chamber experiments on formaldehyde emissions from particle board. These chamber experiments showed that the emissions had a strong positive correlation with the prevailing temperature and humidity conditions. Van Netten et al.Citation22 conducted chamber experiments on various materials (ceiling tile, gypsum board, shiplap, plywood, terracotta brick) that release formaldehyde and reported that higher emissions were observed with increases in temperature, humidity, or both.

In a literature review, MyersCitation23 reported that considerable variations existed between different kinds of boards in their response to varying environmental conditions. MyersCitation23 reports that the temperature coefficients (where log concentration was the dependent variable) for various types of composite wood materials fall within an approximate 2-fold range, as shown in . Further, humidity coefficients for various types of composite wood materials fall within the range of 0.005–0.038 (log RH−1) for log RH.

Table 1. Temperature and humidity coefficient ranges reported in literature

The study also emphasized that significant variations existed among various types of wood in their response to changing temperature and humidity conditions. MyersCitation23 assumed an exponential relationship between the concentration and the inverse of temperature (in K) on the basis of the Arrhenius equation. On the basis of previous studies, he assumes a linear relationship between concentration and RH.Citation24

EXPERIMENTAL METHODS

Materials

Surface materials were cut from THUs for analysis to determine material-specific formaldehyde emission factors. Samples selected for analysis were previously tested for emissions under 23 ± 1 °C in a controlled environmental chamber with a 0.06-m3 hr−1 inlet flow of carbon-filtered preconditioned air at 50% ± 5% RH. These materials included a subfloor (416 μg m−2 hr−1) and cabinet wall (488 μg m−2 hr−1) from trailer 1 manufactured in March 2006, a benchseat (233 μg m−2 hr−1) from trailer 2 manufactured in October 2006, and a cabinet wall (419 μg m−2 hr−1) from trailer 3 manufactured in October 2005. The samples were wrapped in two layers of aluminum foil and then stored in envelopes until the time of testing. The subfloor sample is made from particle board, and the benchseat, cabinet, and cabinet wall samples are all made from plywood.

Humidity Equilibration

Wood is a hygroscopic material; that is, it tends to adsorb or desorb moisture on the basis of the environmental conditions. Humidity equilibration experiments were carried out to determine the time taken by samples to attain equilibrium under conditions of altered humidity. The subfloor (6 × 6 × 3/8 in.) from trailer 1 and the cabinet wall (6 × 6 × ⅛ in.) from trailer 3 were selected for these experiments. All experiments were carried out in four chambers of 10.75-L capacity each. The air exchange rate was maintained at a constant value during all of the experiments. Each material was cut in half along the vertical axis, and the two samples were placed in chambers held at identical temperature and RHs of 50% and 85%. There were four stainless steel chambers installed in a Forma Scientific incubator for temperature control. House air was supplied to each chamber at a rate of 1 L/min. The air was passed through a carbon filter and a high-efficiency particulate air particle filter before being split to each chamber. Further, the purified air to each chamber was split again into a dry line and a wet line (bubbled through deionized water). RH adjustments were made by changing the flow between the wet or dry line that was supplied to each chamber. A Vaisala RH probe and temperature transmitter (P/N HMD30YB) was installed in each chamber to measure the RH changes. LabTech Notebook software was used to continuously log the data over the course of the experiment. The temperature and RH at which the experiments were carried out are listed in . A schematic diagram of the experimental setup is provided in . The samples were weighed using a semimicroanalytical balance Ohaus model DV314C at the start of the experiment and weighed once daily until the weight of the sample reached a constant value. The temperatures in both chambers were altered when the samples attained equilibrium under the temperature and humidity conditions maintained previously.

Table 2. Humidity equilibration experiments

Figure 1. Schematic diagram of experimental setup humidity equilibration experiments.

Figure 1. Schematic diagram of experimental setup humidity equilibration experiments.

Formaldehyde Emissions under Various Temperature and Humidity Conditions

Two samples were cut from each material according to the dimensions specified in and prepared for emission studies. Stainless steel backing plates were cleaned twice with methanol, air-dried, and baked overnight at 50 °C in an oven. The backing plates were taped to the back of the samples using Scotch 3M metal repair tape. Four pieces of tape were used to seal the edges of the material and to hold the backing plate in place.

Table 3. Overview of experiments and measured steady-state concentrations of formaldehyde in chamber experiments

The two samples from each material were placed in chambers held at identical temperature and RHs of 50% and 85%. The experiments were carried out at the various temperature and RH conditions specified in . The samples were placed in the chamber for an average of 1 hr before the air sampling was started. The air sampling for analysis was conducted daily for each chamber until the formaldehyde concentration was found to reach a steady value. Each sample was retained in the chamber under specified conditions of temperature and humidity until it equilibrated with the surrounding atmosphere. Blank samples were taken in empty chambers and with tape to measure background formaldehyde concentrations.

Formaldehyde Sampling and Analysis

The air samples were drawn directly from each small emission chamber. Samples were collected using a vacuum pump (model DOAP104-AA; Gast) with sample flow rates regulated by electronic mass flow controllers. Aldehyde samples were collected on commercially available silica gel cartridges coated with 2,4-dinitrophenylhydrazine (XPoSure aldehyde sampler; Waters Corporation). Sample cartridges were capped, sealed in an aluminum envelope, and stored in the freezer until extraction. Cartridges were eluted with 2 mL of lowcarbonyl-grade, high-purity acetonitrile into 2-mL volumetric flasks, and the eluent was brought to a final volume of 2 mL before analysis. Extracts were analyzed by high-performance liquid chromatography (HPLC) (1200 series; Agilent Technologies) using a C18 reverse-phase column with a 65%:35% water:acetonitrile mobile phase at 0.35 mL/min and ultraviolet detection at 360 nm. Multipoint calibrations were prepared using commercially available hydrazone derivatives of formaldehyde.

Quality Assurance

All samples were quantified with multipoint calibration curves prepared from pure chemicals. Analytical blanks were included in all analyses. Blanks for the emission experiments included backing plate and tape. Chamber blanks representing only the background in the chamber were also collected. Standards were purchased from Supelco. Dintrophenylhydrazone derivatives of formalde-hyde (P/N 47177), acetaldehyde (P/N 47340-U), and acetone (P/N 47341) were dissolved in acetonitrile and used to create a calibration curve for the HPLC analysis method. A midrange standard was run with each batch of samples to confirm the calibration and retention times of each analyte.

DATA ANALYSIS AND RESULTS

Emission Rate

The emission factors were normalized to the surface area of the samples. The steady-state form of the mass balance equation for calculating area-specific emission factors (EF; μg m−2 hr−1) in a well-mixed system is

(1)
where f (m3 hr−1) is the ventilation rate, A (m2) is the exposed surface area of the sample, C (μg m−3) is the measured steady-state concentration in the chamber, and C 0 (μg m−3) is the background concentration in the chamber.

RESULTS AND DISCUSSION

and show the results from the humidity equilibration experiments for the cabinet wall and subfloor samples. The goal of these experiments was to estimate the time for the samples to equilibrate with the environmental conditions. It is seen in and that the moisture gain by both samples was significantly high during the 50% RH, 15 °C and 85% RH, 15 °C conditions. The samples were first exposed to 50% RH, 15 °C and 85% RH, 15 °C conditions when the sampling began. The sudden exposure to high humidity after they were stored for a few months wrapped in aluminum foil resulted in higher levels of moisture uptake under these conditions. As shown by and , the samples take approximately 40 hr to equilibrate. However, under the 85% RH, 15 °C conditions, the samples take approximately 240 hr to reach equilibrium.

Figure 2. Results from humidity equilibration experiments: (a) cabinet wall sample and (b) subfloor sample.

Figure 2. Results from humidity equilibration experiments: (a) cabinet wall sample and (b) subfloor sample.

To analyze the effect of temperature and humidity on aldehyde emissions, a total of six experiments were carried out for each sample. The experiments lasted until the steady-state concentration of formaldehyde remained constant. The results are tabulated in , where it can be seen that the concentration of formal-dehyde increases between 1.9–3.5 times for a 10 °C rise in temperature depending on the sample type. Humidity does not influence the emissions as strongly as temperature. However, a 35% increase in humidity can increase the emissions by 1.8–2.6 times depending on the material. The effect of humidity on emission is more pronounced at higher temperatures.

Temperature and RH have a strong positive correlation with the emission factors for all of the samples. The correlation coefficient (R 2) between temperature and emission factors for all samples was found to be greater than 0.83, and the R 2 between RH and emission factor for all samples was found to be greater than 0.98. Temperature and RH were not correlated (−0.05 < R2 < 0.03).

A linear regression model was built setting the natural log of emission factors as the dependent variable. Natural log of percent RH and inverse of temperature were used as the independent variables. The coefficients of inverse temperature and log RH with log emission factor were found to be statistically significant for all of the samples at the 95% confidence level, as shown in . show the Arrhenius plots of modeled and measured emission factors versus temperature and humidity. The inverse temperature coefficient for the benchseat, cabinet, cabinet wall, and subfloor were −6740, −8500, −7030, and −9940 K, respectively. The log RH coefficients for the benchseat, cabinet, cabinet wall, and subfloor were 1.55, 1.47, 1.42, and 1.17 log RH−1, respectively. The regression model also yielded excellent fits with the experimental data as shown in .

Table 4. Linear regression modeling results

Figure 3. Arrhenius plot of modeled and predicted emission factors as a function of temperature and RH: (a) benchseat sample, (b) cabinet sample, (c) cabinet wall sample, and (d) subfloor sample.

Figure 3. Arrhenius plot of modeled and predicted emission factors as a function of temperature and RH: (a) benchseat sample, (b) cabinet sample, (c) cabinet wall sample, and (d) subfloor sample.

Previous studies assumed a linear relationship between concentration and RH.Citation24 Hence, this study assumes a linear relationship between emission rate and RH. However, a direct comparison of the humidity coefficients generated in the study presented here with previous work is not possible. WuCitation25 applied the wood water adsorption dynamics developed by NelsonCitation26 to wood composite products. The sorption isotherm exhibits a fairly linear trend between approximately 20 and 90% RH. On the basis of the analysis by Wu,Citation24 the results generated in this study could be applied over the 20–90% RH range. MyersCitation23 assumed an exponential relationship between the concentration and the inverse of temperature, and this study assumes an exponential relationship between the emission rate and the inverse of temperature. The ventilation rates and exposed area for each sample are fairly constant across all experimental conditions. The emission factors are related to the concentration by an almost constant factor for each sample. Hence, the log of emission factors and log of concentration vary in a similar linear fashion with change in temperature. Hence, an order of magnitude and sign comparison can be made between the temperature coefficients generated in the regression analysis and the values reported in the literature. MyersCitation23 states that the temperature coefficients reported for various types of composite wood materials fall in the range of −11,120 to −5620 K. The temperature coefficients estimated in this study for particle board falls within this range. Additionally, MyersCitation23 reports temperature coefficients for plywood in the range of −9600 to −7430 K. The temperature coefficient estimated for the particle board sample (−9940 K, subfloor) and plywood (−8500 K, cabinet) falls within this reported range whereas the temperature coefficients for the benchseat and cabinet wall plywood samples (−6740 and −7030 K, respectively) fall close to this reported range. Previous studies report that higher emission rates are observed with increase in ventilation rates; however, the current experiments were carried out at a constant ventilation rate of 5.7 hr-1. The study is limited to observing the effects of temperature and RH on formaldehyde emission factors, when the ventilation rates are held constant and the formaldehyde concentrations in the chamber are constantly changing.

CONCLUSIONS

Chamber experiments were carried out to gauge the effect of temperature and humidity on formaldehyde emission factors. The experiments established that 10 °C variation in temperature increased the formaldehyde emissions 1.9–3.5 times, and a 35% increase in RH can increase the emissions by a factor of 1.8–2.6. Linear regression models were built in which the natural log of emission factors was the dependent variable and the natural log of RH and inverse of temperature served as the independent variables. The coefficient of inverse temperature was found to be in agreement with values previously reported in literature. Most of the available literature on temperature and RH effects on formaldehyde emissions was reported before 1990. A comparison of temperature coefficients calculated from this study with previously reported values also establishes that there has not been any significant change in the way composite wood surface materials respond to increases in temperature. The experiments were limited to a few samples from the THUs. However, the effects of temperature and humidity reported in this study could be incorporated into an exposure analysis for occupants of THUs.

ACKNOWLEDGMENTS

This work was supported by interagency agreement 08FED894632 by the National Center for Environmental Health of the Centers for Disease Control and Prevention and the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs of the U.S. Department of Energy under contract DE-AC02-05CH11231. The authors thank William Fisk and Mohamad Sleiman for their reviews of this paper.

REFERENCES

  • 1999 . Toxicological Profile for Formaldehyde , Atlanta , GA : Agency for Toxic Substances and Disease Registry; U.S. Department of Health and Human Services; Public Health Service .
  • Andersen , I. and Molhave , L. 1983 . “ Controlled Human Studies with Formalde-hyde ” . In Formaldehyde Toxicity , Edited by: Gibson , J.E. 154 – 165 . DC : Hemisphere Washington .
  • Bender , J.R. , Mullin , L.S. , Graepel , G.J. and Wilson , W.E. 1983 . Eye Irritation Response of Humans to Formaldehyde . Am. Ind. Hyg. Assoc. J. , 44 : 463 – 465 .
  • Main , D.M. and Hogan , T.J. 1983 . Health Effects of Low-Level Exposure to Form-aldehyde . J. Occup. Med. , 25 : 896 – 900 .
  • Holness , D.L. and Nethercott , J.R. 1989 . Health Status of Funeral Workers Exposed to Formaldehyde . Arch. Environ. Health , 44 : 222 – 228 .
  • Alexandersson , R. and Hedenstierna , G. 1989 . Pulmonary Function in Wood Workers Exposed to Formaldehyde: A Prospective Study . Arch. Environ. Health , 44 : 5 – 11 .
  • Kerns , W.D. , Pavkov , K.L. , Donofrio , D.J. , Gralla , E.J. and Swenberg , J.A. 1983 . Carcinogenicity of Formaldehyde in Rats and Mice after Long-Term Exposure . Cancer Res. , 43 : 4382 – 4391 .
  • Albert , R.E. , Sellakumar , A.R. , Laskin , S. , Kirschner , M. , Nelson , N. and Snyder , C.A. 1982 . Nasal Cancer in the Rat Induced by Gaseous Formalde-hyde and Hydrogen Chloride . J. Natl. Cancer Inst. , 68 : 597 – 603 .
  • Olsen , J.H. , Jensen , S.P. , Hink , M. , Faurbo , K. , Breum , N.O. and Jensen , O.M. 2006 . Occupational Formaldehyde Exposure and Increased Nasal Cancer Risk in Man . Intl. J. Cancer , 34 : 639 – 644 .
  • Freeman , L.E.B. , Blair , A. , Lubin , J.H. , Stewart , P.A. , Hayes , R.B. , Hoover , R.N. and Hauptmann , M. 2009 . Mortality from Lymphohematopoietic Malignancies among Workers in Formaldehyde Industries . J. Natl. Cancer Inst. , 101 : 751 – 761 .
  • Integrated Risk Information System (IRIS) on Formaldehyde; National Center for Environmental Assessment; Office of Research and Development: Washington, DC, 1999 http://www.epa.gov/IRIS/subst/0419.htm (http://www.epa.gov/IRIS/subst/0419.htm) (Accessed: 1 July 2010 ).
  • Final Report on Formaldehyde Levels in FEMA-Supplied Trailers, Park Models, and Mobile Homes; Centers for Disease Control and Prevention: Atlanta, GA, 2008 http://www.cdc.gov/nceh/ehhe/trailerstudy (http://www.cdc.gov/nceh/ehhe/trailerstudy) (Accessed: 1 October 2009 ).
  • Toxic Trailers: Tests Reveal High Formaldehyde Levels in FEMA Trailers; Sierra Club: San Francisco, CA, 2008 http://www.sierraclub.org (http://www.sierraclub.org) (Accessed: 1 October 2009 ).
  • NIOSH Pocket Guide to Chemical Hazards and Other Databases . NIOSH 2004-103 . 2003 . Department of Health and Human Services; Center for Disease Control and Prevention; National Institute for Occupational Safety and Health: Cincinnati, OH
  • Maddalena , R. , Russell , M. , Sullivan , D.P. and Apte , M.G. Aldehyde and Other Volatile Organic Chemical Emissions in Four FEMA Temporary Housing Units . Report LBNL-254E . 2008 . Lawrence Berkeley National Laboratory: Berkeley, CA
  • Maddalena , R. , Russell , M. , Sullivan , D.P. and Apte , M.G. 2009 . Formaldehyde and Other Volatile Organic Chemical Emissions in Four FEMA Temporary Housing Units . Environ. Sci. Technol. , 43 : 5626 – 5632 .
  • Hodgson , A.T. Common Indoor Sources of Volatile Organic Compounds: Emission Rates and Techniques for Reducing Consumer Exposures . Final Report; Contract No. 95-302 . 1999 . California Air Resources Board: Sacramento, CA
  • 1980 . Formaldehyde—an Assessment of its Health Effects, Committee on Toxicology , Washington , DC : Board on Toxicology and Environmental Health Hazards; National Research Council; National Academy of Sciences .
  • Hawthorne , A.R. and Matthews , T.G. 1987 . Models for Estimating Organic Emissions from Building Materials: Formaldehyde Example . Atmos. Environ. , 21 : 419 – 424 .
  • Zhang , Z. , Luo , X. , Wang , X. , Qian , K. and Zhao , R. 2007 . Influence of Temperature on Formaldehyde Emission Parameters of Dry Building Materials . Atmos. Environ. , 41 : 3203 – 3216 .
  • Anderson , I. , Lundqvist , G.R. and Molhave , L. 1975 . Indoor Air Pollution Due to Chipboard Used as a Construction Material . Atmos. Environ. , 9 : 1121 – 1127 .
  • Van Netten , C. , Shirtliffe , C. and Svec , J. 1989 . Temperature and Humidity Dependence of Formaldehyde Release from Selected Building Materials . Bull. Environ. Contam. Toxicol. , 42 : 558 – 565 .
  • Myers , G.E. 1985 . The Effects of Temperature and Humidity on Formalde-hyde Emission from UF-Bonded Boards: A Literature Critique . Forest Prod. J. , 35 : 20 – 31 .
  • Berge , A. and Mellegaard , B. 1980 . Formaldehyde Release from Particleboard-Evaluation of a Mathematical Model . Eur. J. Wood & Wood Prod. , 38 : 251 – 255 .
  • Wu , Q. 1999 . Application of Nelson's Sorption Isotherm to Wood Composites and Overlays . Wood Fibre Sci. , 31 : 187 – 191 .
  • Nelson , R.M. 1983 . A Model for Sorption of Water Vapor by Cellulosic Materials . Wood Fibre Sci. , 15 : 8 – 22 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.