Prevalence of antibacterial resistant bacterial contaminants from mobile phones of hospital inpatients

, , , , , & show all
Article: 25451 | Received 13 Jul 2014, Accepted 10 Sep 2014, Published online: 13 Oct 2014

Abstract

Mobile phones contaminated with bacteria may act as fomites. Antibiotic resistant bacterial contamination of mobile phones of inpatients was studied. One hundred and six samples were collected from mobile phones of patients admitted in various hospitals in Jazan province of Saudi Arabia. Eighty-nine (83.9%) out of 106 mobile phones were found to be contaminated with bacteria. Fifty-two (49.0%) coagulase-negative Staphylococcus, 12 (11.3%) Staphylococcus aureus, 7 (6.6%) Enterobacter cloacae, 3 (2.83%) Pseudomonas stutzeri, 3 (2.83%) Sphingomonas paucimobilis, 2 (1.8%) Enterococcus faecalis and 10 (9.4%) aerobic spore bearers were isolated. All the isolated bacteria were found to be resistant to various antibiotics. Hence, regular disinfection of mobile phones of hospital inpatients is advised.

Health care–associated infections have increased significantly during the last decade. These infections remain a major cause of morbidity and mortality, which in turn lead to an increase in the cost of health care and also to new health care hazards for the community (Citation1). Earle H Spaulding has categorized patient care items and instruments as critical, semi-critical and non-critical according to the degree of risk involved in use of the items (Citation2). Non-critical items are further divided in to non-critical patient care items and non-critical environmental surfaces (Citation3). Bedpans, blood pressure cuffs, crutches and computers are classified under non-critical patient care items. Bed rails, some food utensils, bedside tables, patient furniture and floors come under non-critical environmental surfaces. Surfaces of medical equipment such as x-ray machines, haemodialysis machines, stethoscopes and blood pressure cuffs can become contaminated with pathogens and lead to the spread of nosocomial infections (Citation2).

Health care workers and patients admitted in various hospitals use mobile phones for communication. As per the classification of Earle H Spaulding (Citation2), a mobile phone comes under non-critical items because it will not contact mucous membranes and/or non-intact skin. Mobile phones of health care workers provide a reservoir of bacteria known to cause nosocomial infection but the contamination of mobile phones of inpatients and their cross contamination is currently unknown (Citation4) and to date, there is no report on antimicrobial resistant bacterial contamination of mobile phones of inpatients. Hence, the present study was carried out to determine contamination of antimicrobial resistant bacteria on mobile phones of patients admitted in various hospitals.

Materials and methods

One hundred and six samples were collected from mobile phones of patients admitted in various hospitals in Jazan province Saudi Arabia. Each sterile swab was moistened with sterile saline and then the swab was rotated on the key of mobile phones and sides of mobile phones. After collection, swabs were immediately inoculated into brain heart infusion broth and incubated aerobically at 37°C for 24 hours (Citation4). After 24 hours of incubation in brain heart infusion broth, growth was noted and further sub-cultured on MacConkey agar, blood agar and chocolate agar and incubated at 37°C for 24 hours. All agar plates were observed for growth, colony morphology and Gram reaction. Depending on colony characters and Gram reactions, all isolates were subjected to identification and antibiotic sensitivity test using VITEK2 (Biomerieux, France) with advanced expert system. Condensed plastic reagent cards (microquantities of antibiotics and media present in wells) are used in VITEK2 system. The VITEK2 system automatically checks for bacterial growth during an incubation period. VITEK 2 follows Clinical and Laboratory Standards Institute (CLSI) guidelines (Citation5). For identification of bacteria, both Gram positive (GP ID card) and Gram negative (GN ID card) cards (Biomerieux, France) were used and for antibiotic susceptibility test both Gram positive and Gram negative susceptibility test cards (AST-P580; AST-N117; Biomerieux, France) were used.

Results

Eighty-nine (83.9%) out of 106 mobile phones of patients admitted in various hospital were contaminated with bacteria. Fifty-two (49.0%) coagulase-negative Staphylococcus, 12 (11.3%) Staphylococcus aureus, 7 (6.6%) Enterobacter cloacae, 3 (2.83%) Pseudomonas stutzeri, 3 (2.83%) Sphingomonas paucimobilis, 2 (1.8%) Enterococcus faecalis and 10 (9.4%) aerobic spore bearers were found ().

Table 1 Various types of bacteria isolated from mobile phones of patients

Results of antibiotic resistance of Gram positive and Gram negative bacterial isolates are listed in Table and 3 , respectively.

Table 2 Antibiotic resistance of various Gram positive bacterial isolates from mobile phones of patients

Table 3 Antibiotic resistance of various Gram negative bacterial isolates from mobile phones of patients

Coagulase-negative Staphylococcus strains were resistant to benzylpenicillin (100%), rifampicin (100%), fusidic acid (96%), fosfomycin (79.2%), tobramycin (70.8%), erythromycin (62.5%), gentamicin (53.8%), clindamycin (40.5%), levofloxacin (32.7%), moxifloxacin (18%) and teicoplanin (13%). S aureus strains were resistant to benzylpenicillin (100%) and erythromycin (83.3%).

E. cloacae complex strains were resistant to ampicillin (100%), piperacillin/tazobactam (100%), cefuroxime axetil (100%), cefoxitin (100%) and cefuroxime (85.7%). P. stutzeri strains were resistant to cefalothin (66.6%), cefotaxime (66.6%), cefuroxime axetil (66.6%), cefoxitin (66.6%), cefpodoxime (66.6%), nitrofurantoin (66.6%) and trimethoprim/sulfamethoxazole (33.3%). S. paucimobilis strains were resistant to ampicillin (33.3%), cefalothin (33.3%), cefotaxime (33.3%), cefuroxime axetil (33.3%), gentamicin (33.3%) and nitrofurantoin (33.3%).

Discussion

Bacterial contamination of mobile phones of hospital inpatients was reported in the United Kingdom (UK). Brady (Citation4) found 86 (84.3%) out of 102 mobile phones of patients admitted in hospital to be contaminated with bacteria (Citation2) whereas in the present study, 89 (83.9%) out of 106 mobile phones of patients admitted in various hospitals were found to be contaminated with bacteria.

All isolated bacteria in the present study were identified up to species level such as coagulase-negative Staphylococcus, S. aureus, E. cloacae, P. stutzeri, S. paucimobilis, E. faecalis and aerobic spore bearers whereas Brady (Citation4) reported coagulase-negative staphylococci, S. aureus, Corynebacterium (jeikeium, pseudodiphtheriticum, urealyticum), Streptococcus species (constellatus, parasanguinis), S. paucimobilis, Enterococcus faecium, Rhizobium species, Acinetobacter ursingii, E. cloacae, Moraxella species, Micrococcus species, Burkholderia cepacia, Dermacoccus species, Kocuria species, Lactococcus species, Gemella species, Bacillus species, unidentified Gram positive bacillus, unidentified alpha-haemolytic streptococcus and Candida albicans from mobile phones of hospital inpatients (Citation2).

No risk has been reported for the transmission of pathogens to patients through non-critical items (Citation6) such as mobile phones which do not contact mucous membranes and /or non-intact skin (Citation2). However, isolated organisms such as coagulase-negative staphylococci have emerged as a major pathogen in implant users and severely debilitated patients in hospitals; S. aureus is a known pathogen, P. stutzeri is an opportunistic pathogen (Citation1) and S. paucimobilis were reported to cause nosocomial infection (Citation7). Since E. faecalis and E. cloacae are part of human intestinal microbial flora (Citation8), isolation of E. faecalis and E. cloacae from mobile phones may indicate that such mobile phones may be contaminated with intestinal flora. Several studies have also reported antibiotic resistant hospital strains such as Staphylococcus epidermidis, S. aureus, Enterococcus, and Pseudomonas species, etc. which are common health care–associated pathogens (Citation2).

In the present study, MRSA were not isolated among isolates of S. aureus and ESBL were not isolated among isolates of E. cloacae, P. stutzeri and S. paucimobilis. All bacterial isolates from mobile phones are aerobes or facultative anaerobes. The possibility of other microorganisms like obligate anaerobes and fungi being found on contaminated mobile phones has not been excluded.

Educating patients about infection control and stressing individual responsibility of infection control is an important aspect of controlling nosocomial infections (Citation9). Contaminated mobile phones may act as fomites because most people carry mobile phones along with them to places such as hospitals, toilets and kitchens where microorganisms thrive (Citation10).

This study indicates that unreported antibiotic resistant bacterial contaminants of mobile phones of patients may be a matter of great concern. Hence, it is recommended that all patients admitted in hospitals be educated about guidelines of using mobile phones, regular disinfection of their mobile phones, hand hygiene and be advised not to share mobile phones with other people so that role of contaminated mobile phones in the spread of nosocomial infections can be prevented to some extent.

Conflict of interest and funding

Authors declare that they have no conflict of interest.

Acknowledgements

Dr. Hussein M Ageely MD, MACG. Dean, Faculty of Medicine and College Applied Medical Sciences, for his help and cooperation in conducting the research.

References

  • Slack RCB. Greenwood D, Slack RCB, Peutherer JF. Hospital infection. Medical microbiology. 2003; Churchill Livingstone. 662–69. 16th ed.
  • Rutala WA. Waber DJ, and the health care infection control practices advisory committee. Guidelines for disinfection and sterilization in health care facilities. 2008. Available from: http://www.cdc.gov/hicpac/pdf/guidelines/Disinfection_Nov_2008.pdf.
  • Sehulster L, Chinn RYW. Healthcare Infection Control Practices Advisory Committee. Guidelines for environmental infection control in health-care facilities. MMWR. 2003; 52: 1–44. [PubMed Abstract].
  • Brady RR, Hunt AC, Visvanathan A, Rodrigues MA, Graham C, Rae C, etal. Mobile phone technology and hospitalized patients: a cross-sectional surveillance study of bacterial colonization, and patient opinions and behaviours. Clin Microbiol Infect. 2011; 17: 830–35.
  • Reiler B, Weinstein M, Jorgensen JH, Ferraro MJ. Antimicrobial susceptibility testing: a review of general principals and contemporary practices. Clin Infect Dis. 2009; 49: 1749–55.
  • Weber DJ, Rutala WA. Wenzel RP. Environmental issues and nosocomial infections. Prevention and control of nosocomial infections. 1997; Baltimore, MD: Williams and Wilkins. 491–514.
  • Ryan MP, Adley CC. Sphingomonas paucimobilis: a persistent Gram-negative nosocomial infectious organism. J Hosp Infect. 2010; 75: 153–57.
  • Hee-Kyung P, Sung-Sub S, Su-Yung K, Jae-Hong P, Su-Eun P, Hak-Jung K, etal. Molecular analysis of colonized bacteria in a human new born gut. J Microbiol. 2005; 43: 345–53.
  • Bolyard EA, Tablan OC, Williams WW, Pearson ML, Shapiro CN, Deitchman SD. Guideline for infection control in health care personnel, CDC personnel health guidelines. AJIC. 1998; 26: 289–351.
  • Bhoonderowa A, Gookool S, Biranjioa-Hurdoyal SD. The importance of mobile phones in the possible transmission of bacterial infections in the community. J Community Health. 2014; 39(5): 965–7. [PubMed Abstract].