References
- Vietnamese National Institute of Ophthalmology. Document presented to the NGO meeting of May 1993, based on the 1990 blindness survey. On file at the Fred Hollows Foundation, Sydney, Australia.
- Hoffer ICJ. Biometry of 7500 cataractous eyes. Am J Ophthalmol 1980;90:360–8.
- Sanders DR, Retzlaff JA, Kraff MC,Gimbel HV, Raanan MG. Comparison of the SRIC/T formula and other theoretical and regression formulas. J Cataract Refract Surg 1990;16:341–6.
- La Nauze J, Ho H. IOL power prediction at the Vietnamese National Institute of Ophthalmology, 1996. On file at the Fred Hollows Foundation, Sydney, Australia.
- Ong S, Ruit S. Axial length and intraocular lens power - A study of 634 Nepalese > 50 years. The Tilganga Eye Centre, 1995. On file at the Fred Hollows Foundation, Sydney, Australia.
- Psilas K, Kalogeropoulos C, Aspiotis M, Nikolaou V. The effect of cataract type on the intraocular lens power calculation using the SRK Formula. Eur J Implant Refract Surg 1992;4:255–9.
- Connell B, Brian G, Bond M. A case control study of biometry in healthy and cataractous Eritrean eyes. Ophthalm Epidemiol 1997;4(3):151–5.
- Hoffer ICJ. Axial dimension of the human cataractous lens. ArchOphthalmol 1993;111:914–8.
- Prior C, O'Day J, Ramsay R.J, Stephens R. IOL prediction: an evaluation of preoperatively determined intraocular lens power accuracy. Aust J Ophthalmol 1988;16:111–7.
- Singh K, Sommer A, Jensen AD, Payne JW. Intraocular lens power calculations, a practical evaluation in normal subjects at the Wilmer Institute. Arch Ophthalmol 1987;105:1046–50.
- Holladay JT, Hoffer K. A-scan biometry and IOL implant power calculations. Focal Points Am Acad Ophthalmol I995;XIII(I0):I0.
- Schelenz J, Kammann J. Comparison of contact and immersion techniques for axial length measurement and implant power calculation. J Cataract Refract Surg 1989; 15:425–8.
- Shammas HJF. A comparison of immersion and contact techniques for axial length measurement. Am Intra-Ocular Implant Soc J 1984;10:444–7.
- Coleman DJ, Lizzi FL, Franzen LA, Abramson DH: A determination of the velocity of ultrasound in cataractous lenses. Bibl Ophthalmol 1975;83:246–51.
- Jansson F. Measurement of intraocular distances by ultrasound and comparison between optical and ultrasonic determinations of depth of anterior chamber. Acta Ophthalmol 1963;41:25–61.
- Olsen TJ. Sources of error in intraocular lens power calculation. J Cataract Refract Surg 1992;18:125–9.
- Naeser K, Naeser A, Boberg-Ans J, Bargum R. Axial length following implantation of posterior chamber lenses. J Cataract Refract Surg 1989;15:673–5.
- Olsen T. On the calculation of power from curvature of the cornea. Br J Ophthalmol 1986; 70:152–4.
- Bishara SA, Goya V, Rand WJ. Cataract and ocular parameters: sexual comparison. Ann Ophthalmol 1988;20:73–4.
- Richards SC, Brodstein DE, Olson RJ, et al. Differences between men and women related to intraocular lens implantation. Ophthalm Surg 1986;17:82–7.
- Wilson A, Woo G. A review of the prevalence and causes of myopia. Singapore Med J 1989;30:479–84.
- Lin LL, Chen C, Hung P, Ko L. Nation-wide survey of myopia among schoolchildren in Taiwan, 1986. Acta Ophthalmol Supp (Copenh) 1988;185:29–33.
- Au Eong KG, Tay TH, Lim MK. Race, culture and myopia in 110,236 young Singaporean males. Singapore Med J 1993;34: 29–32.