References
- Subram Anian V. A., Mccabe J. C., Geller C. M. Minimally invasive direct coronary artery bypass grafting : two-year clinical experience. Ann Thorac Surg, 1997, 64 : 1648-1655.
- Moshkovitz Y., Paz Y., Shabtai E. et al. Predictors of early and overall outcome in coronary artery bypass without cardiopulmonary bypass. Eur J Cardio-lhoracic Surg, 1997, 12 : 31-39.
- Moshkovitz Y., Sternik L., Paz M. A. et al. Primary coronary artery bypass grafting without cardiopulmonary bypass in impaired left ventricular function. Ann Thorac Surg, 1997, 63 : S44-S47.
- Bergsland J., Hasnan S., Lewin A. N., Bhayana J., Lajos T. Z., Salerno T. A. Coronary artery bypass grafting without cardiopulmonary bypass — an attractive alternative in high risk patients. Eur J Cardio-thoracic Surg, 1997, 11 : 876-880.
- Jansen E. L., Grundeman P. F., Beck H. M., Heijmen R. H., Borst C. Experimental off-pump grafting of a circumflex branch via sternotomy using a suction device. Ann Thorac Surg, 1997, 63 : S93-S96.
- Jansen E. L., Grundeman P. F., Borst C. et al. Less invasive off-pump CABG using a suction device for immobilization : the ‘octopus’ method. Eur J Cardio-thoracic Surg, 1997, 12 : 406-412.
- Grundeman P. F., Borst C., Vanherwaarden J. A., Beck H. M., Jansen E. L. Hemodynamic changes during displacement of the beating heart by the Utrecht Octopus method. Ann Thorac Surg, 1997, 63 : S88-S92.
- Edwards F. H., Clark R. E., Schwartz M. Coronary artery bypass grafting : the Society of Thoracic Surgeons National Database experience. Ann Thorac Surg, 1994. 57 : 12-19.
- Jansen E. W., Borst C., Lahpor J. R. et al. Coronary artery bypass grafting without cardiopulmonary bypass using the octopus method : results in the first one hundred patients. J Thorac Cardiovasc Surg, 1998, 116 : 60-67.
- Spooner T. H, Hart J. C., Pym J. A two-year, three institution experience with the Medtronic Octopus : systematic off-pump surgery. Ann Thorac Surg, 1999, 68 : 1478-1481.
- Beard J. D., Scott D. J. A., Evans J. M., Skidmore R., Horrocks M. A Doppler flowmeter for use in vascular surgery. Proc Biol Eng Soc, 1988, 4:6-12.
- Louagie Y. A. G., Haxhe J. P., Jamart J., Buche M., Schoevaerdts J. C. Intraoperative assessment of coronary artery bypass grafts using a pulsed Doppler flowmeter. Ann Thorac Surg, 1994, 58: 742-749.
- Del Rizzo D. F., Boyd W. D., Novick R. J., Mckenzie F. N., Desai J., Menkis A. H. Safety and cost-effectiveness of MID-CABG in high-risk CABG patients. Ann Thorac Surg, 1998, 66 : 1002-1007.
- Perrault L. P., Menasche P., Peynet J. et al. On-pump, beating-heart coronary artery operations in high-risk patients : an acceptable trade-off? Ann Thorac Surg, 1997, 64 : 1368-1373.
- Sweeney M. S., Frazier O. H. Device-supported myocardial revascularization : safe help for sick hearts. Ann Thorac Surg, 1992, 54: 1065-1070.
- Gundry S. R., Romano M. A., Shattuck O. H., Razzouk A. J., Bailey L. L. Seven-year follow-up of coronary artery bypasses performed with and without cardiopulmonary bypass. J Thorac Cardiovasc Surg, 1998, 115 : 1273-1278.
- Poirier N. C., Carrier M., LespÉrance J., CÔtÉ G., Pellerin M., Perrault L. P., Pelletier L. C. Quantitative angiographic assessment of coronary anastomoses performed without cardiopulmonary bypass. J Thorac Cardiovasc Surg, 1999, 117 : 292-297.
- Subramanian V. A. Less invasive arterial CABG on a beating heart. Ann Thorac Surg, 1997, 63 : S68-S71.
- D’Ancona G., Karamanoukian H. L., Salerno T. A., Schmid S., Bergsland J. Graft revision after transit time flow measurement (TTFM) in off-pump coronary artery bypass grafting (CABG) [Abstract, 13th annual meeting of the EACTS]. Eur J Cardio-tho-rac Surg, 1999, 452.
- Louagie Y. Buche M., Eucher P., Schoevaerdts J.-C. Intraoperative flow measurements in gastroepiploic grafts using pulsed Doppler. Eur J Cardio-thorac Surg, 1999, 15 : 240-246.