- SziLAGYi D., France L., Smith K. et al. Clinical .use of an elastic Dacron prosthesis. Arch Surg, 1958, 77: 538–551.
- Abu Rahma A., De Luca J. Multiple non-anastomotic aneurysms in an external velour ringed Dacron femoro-popliteal vascular prosthesis. Ann Vasc Surg, 1995, 9: 493–495.
- Arvatinis D., Georgopoulos S., Derwisis K., Argitis V., Xanthopoulos D. Late non-anastomotic false aneurysm formation in femoro-popliteal polyethylene teraphthalate grafts. Int Angiol, 2001, 20: 348–350.
- Blumenberg K., Gelfand M. Failure of knitted Dacron as an arterial prosthesis. Surgery, 1977, 81: 493–496.
- Chafke N., Riepe G., Dieval F. et al. Longitudinal ruptures of polyester knitted vascular prostheses. J Vasc Surg, 2001, 33: 1015–1021.
- Friedman M., Zelikowsi A., Mor C., Reiss R. True aneurysm in a prosthetic aorto-femoral Dacron graft. J Cardiovasc Surg, 1989, 30: 136–137.
- Irace L., Stumpo R., Costa P. et al. Rupture of Dacron aorto-femoral graft. Case report. J Cardiovasc Surg, 1999, 40: 879–881.
- Khaira H., Vohra H. True aneurysm in a femoro-popliteal Dacron graft. A case report and literature review. Cardiovasc Surg, 2002, 10: 644–646.
- Knox W. Aneurysms occurring in a femoral artery Dacron prosthesis five and one-half year after insertion. Ann Surg, 1962, 156: 827–830.
- May J., Stephen M. Multiple aneurysms in a Dacron velour graft. Arch Surg, 1978, 113: 320–321.
- Muto Y., Miyazaki T., Eguchi H. et al. Aneurysm in a double velour knitted Dacron graft. J Cardiovasc Surg, 1987, 28: 723726.
- Nucho R., Gryboski W. Aneurysm of a double velour aortic graft. Arch Surg, 1984, 119: 1182–1184.
- Nunn D. Structural failure of Dacron arterial grafts. Semin Vasc Surg, 1999, 12: 83–91.
- Nunn D., Pourdeyghimi B. Intrinsic Dacron graft failure 19 years post-implantation. Cardiovasc Surg, 1997, 5: 333–338.
- Opsommer J., Fastrez J. Spontaneous rupture of a Dacron prosthesis. Acta Chir Belg, 2002, 102: 141–144.
- Orii M., Shirasugi N., Yamazaki M., Akiyama Y. Pseudoaneurysm caused by disruption of an externally supported knitted Dacron graft for femoro-popliteal bypass. Tokai J Exp Clin Med, 1995, 20: 241–244.
- Ottinger L., Darling C., Wirthlin L., Linton R. Failure of ultra light weight knitted Dacron grafts in arterial reconstruction. Arch Surg, 1976, 111: 146–149.
- Ratto G., Truini M., Sacco A., Canepa G., Radini A., Motta G. Multiple aneurysmal dilatations in a knitted Dacron velour graft. J Cardiovasc Surg, 1985, 26: 589–591.
- Trippestad A. Late rupture of knitted Dacron double velour arterial prostheses. Acta Chir Scand, 1985, 151: 391–395.
- Vrancken Peeters M., Voorwinde A., Mackaay A., Butzelaar R. Late rupture of femoro-popliteal Dacron grafts: a rare complication. Eur J Vasc Endovasc Surg, 1996, 11: 243–246.
- Watanabe T., Kusata A., Kuma H. et al. Failure of Dacron arterial prostheses caused by structural defects. J Cardiovasc Surg, 1983, 24: 95–100.
- Wilson S., Krig R., Mueller G., Wilson L. Late disruption of Dacron aortic grafts. Ann Vasc Surg, 1999, 11: 383–386.
- Biederer J., Müller-Hülsbeck S., Loose J., Heller M. Late aneurysm formation in a femoro-popliteal polytetrafluoroethylene graft. Eur Radiol, 1999, 9: 1678–1681.
- Geiger G. Deterioration of PTFE prostheses wall. J Cardiovasc Surg, 1991, 32: 660–663.
- Onoe M., Watarida S., Sugita T. et al. Disruption of the expanded polytetrafluoroethylene graft of axillo-femoral bypass. J Cardiovasc Surg, 1994, 35: 165–168.
- Piazza D., Ameli F., Von Schroeder H., Lossing A. Non-anasto-motic pseudoaneurysm of expanded polytetrafluoroethylene axil-lo-femoral bypass graft. J Vasc Surg, 1993, 17: 777–779.
- Berger K., Sauvage L. Late fiber deterioration in Dacron arterial grafts. Ann Surg, 1981, 193: 477–491.
- Pourdeyhimi B., Wagner D. On the correlation between the failure of vascular grafts and their structural and material properties. A critical analysis. J Biomed Mat Res, 1986, 20: 375–409.
- Dardik H., Greisler H. History of prosthetic grafts. Semin Vasc Surg, 1999, 12: 1–7.
- Voorhees A., Jaretski A., Blakemore A. The use of tubes constructed from Vinyon «N» cloth in bridging arterial defects. Ann Surg, 1952, 135: 332–335.
- Schumacker H. Jr., King H. The use of pliable plastic tubes as aortic substitutes in man. Surg Gynecol Obst, 1954, 94: 287–294.
- Harrison J., Alder R. Nylon as vascular prosthesis in experimental animals with tensile strength studies. Surg Gynecol Obst, 1956, 103: 613–627.
- Lynn R. Knitted Dacron ultra-light weight grafts. A warning. Can J Surg, 1979, 22: 593.
- Jacobs T., Won J., Graveraux E. Mechanical failure of prosthetic human implants. A 10-year experience with aortic stent graft devices. J Vasc Surg, 2003, 37: 16–26.
- Zarins C., Arko F., Crabtree T. et al. Explant analysis of aneurRx stent grafts: relationship between structural findings and clinical outcome. J Vasc Surg, 2004, 40: 1–11.
- Hall C. W., Liotta D., Chidoni J., De Bakey M. Velour fabrics applied to medicine. J Biomed Mater Res, 1967, 15: 179–196.
- Sauvage L., Berger K., Wood S. et al. An external velour surface for porous arterial prostheses. Surgery, 1971, 70: 940–953.
- Liebig C., Cooley D. Vascular Graft Symposium. National Institute of Health, 1976: Double velour knitted Dacron grafts for aorto-iliac vascular replacement. In: Sawyer P., Kaplett M. (eds.). Vascular Grafts, New York.
- Nunn D., Freeman M., Hudgins P. Postoperative alterations in size of Dacron aortic grafts. Ann Surg, 1979, 189: 741–745.
- Goëau-Brissonniere O., Quanadli S., Ippoliti A., Pistolese G., Coggia M., Pollock J. Can knitting structure affect dilatation of polyester bifurcated prostheses ? A randomised study with the use of helical computed tomography scanning. J Vasc Surg, 2000, 31: 157–163.
- Den Hoed P., Veen H. The late complications of aorto-ilio-femoral Dacron prostheses: dilatation and anastomotic aneurysm formation. Eur J Vasc Surg, 1992, 6: 282–287.
- Nunn D., Carter M., Donohve M., Hudgins P. Postoperative dilatation of knitted Dacron aortic bifurcation graft. J Vasc Surg, 1990, 12: 291–297.
- Clagett P., Salander J., Eddleman W. et al. Dilatation of knitted Dacron prostheses and anastomotic false aneurysms: etiologic considerations. Surgery, 1983, 93: 9–16.
- Robinson D., Lennox A., Englind R., Hanal K. Graft dilatation following abdominal aortic aneurysm resection and grafting. Aust N Z J Surg, 1999, 69: 849–851.
- Erdoes L., Berman S., Berhnard v., Mulcahy M., Hunter G. Clinical and tomodensitometric evaluation of a new aorto-iliac prosthesis of extensible polytetrafluoroethylene. Ann Vasc Surg, 1995, 9: 441–447.
- Greisler H. Interactions at the blood-prosthetic interface. Ann Vasc Surg, 1990, 4: 98–103.
- Mikucki S., Greisler H. Understanding and manipulating the biological response to vascular implants. Semin Vasc Surg, 1999, 12: 18–26.
- Pruitt L. The effects of radiation on structural and mechanical properties of medical polymers. Adv Polym Sci, 2003, 162: 6393.
- Sato O., Okamoto H., Takagi A., Miyata T., Takayama Y. Biodegradation of glutraldehyde-tanned human umbilical vein grafts. Jpn J Surg, 1995, 25: 901–905.